Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

被引:11
作者
Thomas, C. M. [1 ]
Pike, L. C. [2 ]
Hartill, C. E. [3 ]
Baker, S. [2 ]
Woods, E. [2 ]
Convery, D. J. [1 ]
Greener, A. G. [1 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, St Thomas Hosp, Dept Med Phys, London SE1 7EH, England
[2] Kings Coll London, St Thomas Hosp, Kings Hlth Partners, Div Imaging Sci & Biomed Engn, London SE1 7EH, England
[3] Guys & St Thomas NHS Fdn Trust, St Thomas Hosp, Clin Outpatients Clin, London SE1 7EH, England
关键词
radiotherapy; commissioning; direct; PET guided radiotherapy; recommendation; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; SOFT-TISSUE SARCOMA; PHASE-I TRIAL; ATTENUATION CORRECTION; QUALITY-ASSURANCE; CONTRAST-MEDIUM; CANCER; HYPOXIA; TIRAPAZAMINE; NUMBERS;
D O I
10.1118/1.4867856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. Methods: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was tested throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. Results: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. Conclusions: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 31 条
  • [1] AAPM, 2008, 96 AAPM
  • [2] Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
    Abdoli, Mehrsima
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3343 - 3360
  • [3] [Anonymous], 2010, Journal of the ICRU, V10
  • [4] Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET
    Ay, Mohammad Reza
    Zaidi, Habib
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (11) : 1301 - 1313
  • [5] Establishment of a UK-wide network to facilitate the acquisition of quality assured FDG-PET data for clinical trials in lymphoma
    Barrington, S. F.
    MacKewn, J. E.
    Schleyer, P.
    Marsden, P. K.
    Mikhaeel, N. G.
    Qian, W.
    Mouncey, P.
    Patrick, P.
    Popova, B.
    Johnson, P.
    Radford, J.
    O'Doherty, M. J.
    [J]. ANNALS OF ONCOLOGY, 2011, 22 (03) : 739 - 745
  • [6] Three-phase adaptive dose-painting-by-numbers for head-and-neck cancer: initial results of the phase I clinical trial
    Berwouts, Dieter
    Olteanu, Luiza A. M.
    Duprez, Frederic
    Vercauteren, Tom
    De Gersem, Werner
    De Neve, Wilfried
    Van de Wiele, Christophe
    Madani, Indira
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) : 310 - 316
  • [7] FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
    Boellaard, Ronald
    O'Doherty, Mike J.
    Weber, Wolfgang A.
    Mottaghy, Felix M.
    Lonsdale, Markus N.
    Stroobants, Sigrid G.
    Oyen, Wim J. G.
    Kotzerke, Joerg
    Hoekstra, Otto S.
    Pruim, Jan
    Marsden, Paul K.
    Tatsch, Klaus
    Hoekstra, Corneline J.
    Visser, Eric P.
    Arends, Bertjan
    Verzijlbergen, Fred J.
    Zijlstra, Josee M.
    Comans, Emile F. I.
    Lammertsma, Adriaan A.
    Paans, Anne M.
    Willemsen, Antoon T.
    Beyer, Thomas
    Bockisch, Andreas
    Schaefer-Prokop, Cornelia
    Delbeke, Dominique
    Baum, Richard P.
    Chiti, Arturo
    Krause, Bernd J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) : 181 - 200
  • [8] Hypoxia imaging with FAZA-PET and theoretical considerations with regard to dose painting for individualization of radiotherapy in patients with head and neck cancer
    Grosu, Anca-Ligia
    Souvatzoglou, Michael
    Roeper, Barbara
    Dobritz, Martin
    Wiedenmann, Nicole
    Jacob, Vesna
    Wester, Hans-Juergen
    Reischl, Gerald
    Machulla, Hans-Juergen
    Schwaiger, Markus
    Molls, Michael
    Piert, Morand
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02): : 541 - 551
  • [9] ANALYSIS OF EMISSION TOMOGRAPHIC SCAN DATA - LIMITATIONS IMPOSED BY RESOLUTION AND BACKGROUND
    KESSLER, RM
    ELLIS, JR
    EDEN, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) : 514 - 522
  • [10] Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning
    Kilby, W
    Sage, J
    Rabett, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09) : 1485 - 1492