High-intensity focused ultrasound treatment in patients with refractory glaucoma

被引:51
作者
Giannaccare, Giuseppe [1 ]
Vagge, A. [2 ]
Gizzi, C. [1 ]
Bagnis, A. [2 ]
Sebastiani, S. [1 ]
Del Noce, C. [2 ]
Fresina, M. [1 ]
Traverso, C. E. [2 ]
Campos, E. C. [1 ]
机构
[1] Univ Bologna, Ophthalmol Unit, DIMES, Via Pelagio Palagi 9, I-40138 Bologna, Italy
[2] Univ Genoa, Eye Clin, Genoa, Italy
关键词
Ultrasound coagulation; High-intensity focused ultrasound; Intraocular pressure reduction; Refractory glaucoma; LASER TRANSSCLERAL CYCLOPHOTOCOAGULATION; DIODE-LASER; LONG-TERM; ENDOSCOPIC CYCLOPHOTOCOAGULATION; CILIARY BODY; DEVICE; CYCLOCOAGULATION; COAGULATION; NEODYMIUM; ABLATION;
D O I
10.1007/s00417-016-3563-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the safety and efficacy of ultrasound coagulation of the ciliary body in refractory glaucoma. This prospective multicenter interventional study was conducted in two Italian university-affiliated glaucoma centers: St. Orsola-Malpighi Teaching Hospital (Bologna, Italy) and University Eye Clinic of Genoa (Genoa, Italy). The main inclusion criterion was the diagnosis of glaucoma with a baseline intraocular pressure (IOP) ae<yen> 21 mmHg while on maximum topical and systemic medical hypotensive treatment. The EyeOP1 device (Eye Tech Care, Rillieux-la-Pape, France), which was employed in the study, uses miniaturized transducers to produce high-intensity focused ultrasound (HIFU). Treatment consisted of the sequential activation of each transducer lasting 4 s (group 1), 6 s (group 2) or 8 s (group 3). Hypotensive medications were interrupted after surgery and then prescribed only if postoperative IOP was ae<yen> 21 mmHg during follow-up visits. Patients were assessed before and 1, 7, 14, 30, 90 and 180 days after the procedure. Primary outcomes were the mean IOP reduction in the overall population and in groups 1, 2 and 3, and the rates of complete success, qualified success and failure. Thirty eyes (16 open-angle, 10 angle-closure and 4 neovascular glaucoma) of 30 patients were included. The mean preoperative IOP was 30.1 +/- 10.5 mmHg. Twenty-nine patients completed the entire study follow-up; one patient exited from the study 3 months after HIFU and underwent trabeculectomy. At days 1 and 180, the mean IOP was significantly reduced (18.4 +/- 7.2 and 20.2 +/- 6.2 mmHg, respectively; all p < 0.0001). Group 3 patients (8-s ultrasound exposure time) showed a greater IOP reduction than the other two groups (-16.2 +/- 8.3 for group 3 vs. -8.8 +/- 6.6 for group 2 and -3.7 +/- 6.5 for group 1; p = 0.02 and p < 0.001, respectively). Qualified and complete success was achieved in 23.3 and 46.7% of patients, respectively; treatment failure was recorded in 6.6%. Ultrasonic coagulation of the ciliary body is a safe and effective procedure for reducing IOP in refractory glaucoma. The increase in ultrasound exposure time appears to improve the response rate and the global efficacy of the procedure, with no detrimental effect on safety.
引用
收藏
页码:599 / 605
页数:7
相关论文
共 36 条
  • [1] ALGHAMDI S, 1993, OPHTHALMIC SURG LAS, V24, P526
  • [2] Aptel F, 2016, ACTA OPHTHALMOL, V94, pe268, DOI [10.1111/aos.12913, 10.1111/j.1755-3768.2016.0447]
  • [3] SHORT- AND LONG-TERM EFFECTS ON THE CILIARY BODY AND THE AQUEOUS OUTFLOW PATHWAYS OF HIGH-INTENSITY FOCUSED ULTRASOUND CYCLOCOAGULATION
    Aptel, Florent
    Begle, Aurelie
    Razavi, Arash
    Romano, Fabrice
    Charrel, Thomas
    Chapelon, Jean-Yves
    Denis, Philippe
    Lafon, Cyril
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (09) : 2096 - 2106
  • [4] Treatment of refractory open-angle glaucoma using ultrasonic circular cyclocoagulation: a prospective case series
    Aptel, Florent
    Dupuy, Caroline
    Rouland, Jean-Francois
    [J]. CURRENT MEDICAL RESEARCH AND OPINION, 2014, 30 (08) : 1599 - 1605
  • [5] Therapeutic applications of ultrasound in ophthalmology
    Aptel, Florent
    Lafon, Cyril
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2012, 28 (04) : 405 - 418
  • [6] Miniaturized High-Intensity Focused Ultrasound Device in Patients with Glaucoma: A Clinical Pilot Study
    Aptel, Florent
    Charrel, Thomas
    Lafon, Cyril
    Romano, Fabrice
    Chapelon, Jean-Yves
    Blumen-Ohana, Esther
    Nordmann, Jean-Philippe
    Denis, Philippe
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 8747 - 8753
  • [7] Histologic Effects of a New Device for High-Intensity Focused Ultrasound Cyclocoagulation
    Aptel, Florent
    Charrel, Thomas
    Palazzi, Xavier
    Chapelon, Jean-Yves
    Denis, Philippe
    Lafon, Cyril
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) : 5092 - 5098
  • [8] BURGESS SEP, 1986, OPHTHALMOLOGY, V93, P831
  • [9] DEVELOPMENT OF A MINIATURIZED HIFU DEVICE FOR GLAUCOMA TREATMENT WITH CONFORMAL COAGULATION OF THE CILIARY BODIES
    Charrel, Thomas
    Aptel, Florent
    Birer, Alain
    Chavrier, Francoise
    Romano, Fabrice
    Chapelon, Jean-Yves
    Denis, Philippe
    Lafon, Cyril
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (05) : 742 - 754
  • [10] Endoscopic photocoagulation of the ciliary body for treatment of refractory glaucomas
    Chen, J
    Cohn, RA
    Lin, SC
    Cortes, AE
    Alvarado, JA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (06) : 787 - 796