Background Inadvertent injury of the recurrent laryngeal nerve can occur during radiofrequency ablation (RFA) of thyroid nodules. Methods to avoid permanent injury have not been described. Laryngeal ultrasonography (LUSG) can assess the function of vocal cords (VCs) in real time. The present study aimed to evaluate the feasibility and accuracy of LUSG in assessing real-time VC function during RFA of benign thyroid nodules. Methods Consecutive patients undergoing RFA for benign thyroid nodules under local anesthesia were included. Spontaneous VC movements were checked with intra-operative LUSG (iLUSG) following each transverse ablation plane. In case of reduced VC movement, the ablation was stopped immediately. Post-ablation VC function was rechecked by LUSG on day-0 and flexible laryngoscopy (FL) on day-7. A concordance with day-0 LUSG or day-7 FL was a "true positive" or "true negative" depending on the presence or absence of VC palsy (VCP). Accuracy was calculated as the sum of all true positives and negatives divided by total nerves-at-risk. Results Of 65 eligible patients, 56 (86.2%) were females. Twelve (18.5%) patients had bilateral lobe RFA, while 53 (81.5%) had unilateral RFA. The total number of nerves-at-risk was 77. Three unilateral VCPs (3.9%) were initially detected on iLUSG and confirmed by day-0 LUSG. All recovered fully within one week. The overall accuracy of iLUSG was 100%. Conclusion iLUSG is a highly accurate method that permits real-time feedback on the function of the VCs during RFA procedure. Real-time detection of VCP may prevent permanent injury. Methodological routine use of iLUSG is recommended during thyroid RFA.
引用
收藏
页码:2206 / 2211
页数:6
相关论文
共 4 条
  • [1] Transcutaneous Laryngeal Ultrasonography for Assessing Vocal Cord Twitch Response in Thyroid Operation during Predissection Vagus Nerve Stimulation
    Kuo, Ting-Chun
    Chen, Kuen-Yuan
    Lai, Chieh-Wen
    Wang, Yi-Chia
    Lin, Ming-Tsan
    Chang, Chin-Hao
    Wu, Ming-Hsun
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2022, 234 (03) : 359 - 366
  • [2] Ultrasound simulation of real-time temperature estimation during radiofrequency ablation using finite element models
    Daniels, M. J.
    Jiang, J.
    Varghese, T.
    ULTRASONICS, 2008, 48 (01) : 40 - 55
  • [3] Real-time FDG PET Guidance during Biopsies and Radiofrequency Ablation Using Multimodality Fusion with Electromagnetic Navigation
    Venkatesan, Aradhana M.
    Kadoury, Samuel
    Abi-Jaoudeh, Nadine
    Levy, Elliot B.
    Maass-Moreno, Roberto
    Kruecker, Jochen
    Dalal, Sandeep
    Xu, Sheng
    Glossop, Neil
    Wood, Bradford J.
    RADIOLOGY, 2011, 260 (03) : 848 - 856
  • [4] Radiofrequency ablation using real-time ultrasonography-computed tomography fusion imaging improves treatment outcomes for T1a renal cell carcinoma: Comparison with laparoscopic partial nephrectomy
    Chung, Dong Jin
    Hwang, Hyun
    Sohn, Dong Wan
    INVESTIGATIVE AND CLINICAL UROLOGY, 2022, 63 (02) : 159 - 167