Dose variations with varying calculation grid size in head and neck IMRT

被引:52
作者
Chung, Heeteak [1 ]
Jin, Hosang
Palta, Jatinder
Suh, Tae-Suk
Kim, Siyong
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
关键词
D O I
10.1088/0031-9155/51/19/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ever since the advent and development of treatment planning systems, the uncertainty associated with calculation grid size has been an issue. Even to this day, with highly sophisticated 3D conformal and intensity-modulated radiation therapy (IMRT) treatment planning systems (TPS), dose uncertainty due to grid size is still a concern. A phantom simulating head and neck treatment was prepared from two semi-cylindrical solid water slabs and a radiochromic film was inserted between the two slabs for measurement. Plans were generated for a 5400 cGy prescribed dose using Philips Pinnacle(3) TPS for two targets, one shallow (similar to 0.5 cm depth) and one deep (similar to 6 cm depth). Calculation grid sizes of 1.5, 2, 3 and 4 mm were considered. Three clinical cases were also evaluated. The dose differences for the varying grid sizes ( 2 mm, 3 mm and 4 mm from 1.5 mm) in the phantom study were 126 cGy (2.3% of the 5400 cGy dose prescription), 248.2 cGy ( 4.6% of the 5400 cGy dose prescription) and 301.8 cGy (5.6% of the 5400 cGy dose prescription), respectively for the shallow target case. It was found that the dose could be varied to about 100 cGy ( 1.9% of the 5400 cGy dose prescription), 148.9 cGy ( 2.8% of the 5400 cGy dose prescription) and 202.9 cGy ( 3.8% of the 5400 cGy dose prescription) for 2 mm, 3 mm and 4 mm grid sizes, respectively, simply by shifting the calculation grid origin. Dose difference with a different range of the relative dose gradient was evaluated and we found that the relative dose difference increased with an increase in the range of the relative dose gradient. When comparing varying calculation grid sizes and measurements, the variation of the dose difference histogram was insignificant, but a local effect was observed in the dose difference map. Similar results were observed in the case of the deep target and the three clinical cases also showed results comparable to those from the phantom study.
引用
收藏
页码:4841 / 4856
页数:16
相关论文
共 16 条
  • [1] What is the optimum leaf width of a multileaf collimator?
    Bortfeld, T
    Oelfke, U
    Nill, S
    [J]. MEDICAL PHYSICS, 2000, 27 (11) : 2494 - 2502
  • [2] Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer
    Chung, HT
    Jin, HS
    Dempsey, JF
    Liu, CH
    Palta, J
    Suh, TS
    Kim, SY
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2682 - 2689
  • [3] Quantitative optical densitometry with scanning-laser film digitizers
    Dempsey, JF
    Low, DA
    Kirov, AS
    Williamson, JF
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1721 - 1731
  • [4] Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions
    Dempsey, JF
    Low, DA
    Mutic, S
    Markman, J
    Kirov, AS
    Nussbaum, GH
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2462 - 2475
  • [5] A Fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization
    Dempsey, JF
    Romeijn, HE
    Li, JG
    Low, DA
    Palta, JR
    [J]. MEDICAL PHYSICS, 2005, 32 (02) : 380 - 388
  • [6] An immobilization system for claustrophobic patients in head-and-neck intensity-modulated radiation therapy
    Kim, S
    Akpati, HC
    Li, JG
    Liu, CR
    Amdur, RJ
    Palta, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05): : 1531 - 1539
  • [7] Evaluation of intrafraction patient movement for CNS and head & neck IMRT
    Kim, S
    Akpati, HC
    Kielbasa, JE
    Li, JG
    Liu, CR
    Amdur, RJ
    Palta, JR
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 500 - 506
  • [8] SAMPLING TECHNIQUES FOR THE EVALUATION OF TREATMENT PLANS
    LU, XQ
    CHIN, LM
    [J]. MEDICAL PHYSICS, 1993, 20 (01) : 151 - 161
  • [9] RANDOM SAMPLING FOR EVALUATING TREATMENT PLANS
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1990, 17 (05) : 753 - 762
  • [10] THE INFLUENCE OF THE SIZE OF THE GRID USED FOR DOSE CALCULATION ON THE ACCURACY OF DOSE ESTIMATION
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1989, 16 (02) : 239 - 247