Trabecular Bone Assessment Using Magnetic-Resonance Imaging: A Pilot Study

被引:3
作者
Bohner, Lauren [1 ,2 ]
Tortamano, Pedro [2 ]
Meier, Norbert [3 ]
Gremse, Felix [4 ]
Kleinheinz, Johannes [1 ]
Hanisch, Marcel [1 ]
机构
[1] Univ Hosp Muenster, Dept Craniomaxillofacial Surg, D-48149 Munster, Germany
[2] Univ Sao Paulo, Sch Dent, Dept Prosthodont, BR-0508000 Sao Paulo, Brazil
[3] Univ Clin Muenster, Inst Clin Radiol, D-48149 Munster, Germany
[4] Rhein Westfal TH Aachen, Helmholtz Inst, Dept Expt Mol Imaging, D-52074 Aachen, Germany
关键词
dental implants; magnetic-resonance imaging; microCT; COMPUTED-TOMOGRAPHY; ORTHODONTIC APPLIANCES; MRI; CT; ACCURACY; RELIABILITY; ARTIFACTS; IMPLANTS; VOLUME;
D O I
10.3390/ijerph17249282
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to assess trabecular bone morphology via magnetic-resonance imaging (MRI) using microcomputed tomography (mu CT) as the control group. Porcine bone samples were scanned with T1-weighted turbo spin echo sequence imaging, using TR 25 ms, TE 3.5 ms, FOV 100 x 100 x 90, voxel size 0.22 x 0.22 x 0.50 mm, and scan time of 11:18. mu CT was used as the control group with 80 kV, 125 mA, and a voxel size of 16 mu m. The trabecular bone was segmented on the basis of a reference threshold value and morphological parameters. Bone volume (BV), Bone-volume fraction (BvTv), Bone specific surface (BsBv), trabecular thickness (TbTh), and trabecular separation (TbSp) were evaluated. Paired t-test and Pearson correlation test were performed at p = 0.05. MRI overestimated BV, BvTv, TbTh, and TbSp values. BsBv was the only parameter that was underestimated by MRI. High statistical correlation (r = 0.826; p < 0.05) was found for BV measurements. Within the limitations of this study, MRI overestimated trabecular bone parameters, but with a statistically significant fixed linear offset.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 31 条
[1]   Accuracy of magnetic resonance imaging compared with computed tomography for implant planning [J].
Aguiar, Marcelo F. ;
Marques, Alexandre P. ;
Carvalho, Antonio Carlos P. ;
Cavalcanti, Marcelo G. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (04) :362-365
[2]  
[Anonymous], 1985, TISSUE INTEGRATED PR
[3]   Accuracy and Reliability of Cone Beam Computed Tomographic Measurements of the Bone Labial and Palatal to the Maxillary Anterior Teeth [J].
Behnia, Hossein ;
Motamedian, Saeed Reza ;
Kiani, Mohammad Taghi ;
Morad, Golnaz ;
Khojasteh, Arash .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (06) :1249-1255
[4]   Dimensions of buccal bone and mucosa at immediately placed implants after 7 years: a clinical and cone beam computed tomography study [J].
Benic, Goran I. ;
Mokti, Muizzaddin ;
Chen, Chun-Jung ;
Weber, Hans-Peter ;
Haemmerle, Christoph H. F. ;
Gallucci, German O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (05) :560-566
[5]  
Blankenstein F, 2015, J OROFAC ORTHOP, V76, P14, DOI 10.1007/s00056-014-0258-0
[6]   Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging [J].
Blankenstein, Felix H. ;
Asbach, Patrick ;
Beuer, Florian ;
Glienke, Johannes ;
Mayer, Stefan ;
Zachriat, Christine .
CLINICAL ORAL INVESTIGATIONS, 2017, 21 (01) :281-289
[7]   Trends in maxillofacial imaging [J].
Boeddinghaus, R. ;
Whyte, A. .
CLINICAL RADIOLOGY, 2018, 73 (01) :4-18
[8]   Magnetic resonance imaging artifacts produced by dental implants with different geometries [J].
Bohner, Lauren ;
Meier, Norbert ;
Gremse, Felix ;
Tortamano, Pedro ;
Kleinheinz, Johannes ;
Hanisch, Marcel .
DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (08)
[9]   Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters [J].
Bohner, Lauren O. L. ;
Tortamano, Pedro ;
Marotti, Juliana .
DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (05)
[10]   MRI Disturbances Caused by Dental Materials [J].
Bryll, A. ;
Urbanik, A. ;
Chrzan, R. ;
Jurczak, A. ;
Kwapinska, H. ;
Sobiecka, B. .
NEURORADIOLOGY JOURNAL, 2007, 20 (01) :9-17