Correction factors for the analysis of voltammetric peak currents measured using staircase voltammetry

被引:25
作者
Batchelor-McAuley, Christopher [1 ]
Yang, Minjun [1 ]
Hall, Elise M. [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
基金
欧洲研究理事会;
关键词
Electrochemistry; Diffusion coefficient; Electron transfer kinetics; Randle-sevcik equation; CYCLIC VOLTAMMETRY; LINEAR SCAN; GENERAL EQUIVALENCE; ELECTRODE-KINETICS; POLAROGRAPHY; DIFFUSION; SWEEP;
D O I
10.1016/j.jelechem.2015.10.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of staircase voltammetry for the measurement of reversible diffusional redox species under a linear mass-transport regime leads to significant suppression of the peak currents (up to 20% for larger step sizes) and an increase in the peak-to-peak separation (cf. Delta E-pp similar to 70 mV at the reversible limit as opposed to 57 mV). These discrepancies between the voltammetric results of a staircase and true analogue voltammogram may lead to mis-interpretation of data. This work provides an overview of the differences between the two techniques in the macro-electrode reversible limit and provides new expressions which allow the peak current of a staircase voltammogram to be quantitatively analysed. Moreover, clear guidance is provided about which conditions the application of the provided equation is valid in the terms of mass-transport edge effects to the macro-electrode. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 29 条
[1]   Ultrafast cyclic voltammetry: performing in the few megavolts per second range without ohmic drop [J].
Amatore, C ;
Maisonhaute, E ;
Simonneau, G .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (02) :81-84
[2]  
[Anonymous], 2014, ABS14111607 CORR
[3]  
[Anonymous], ANAL CHEM
[4]  
Bard A.J., 2001, Electrochemical Methods: Fundamentals and Applications, V2
[5]   SQUARE WAVE POLAROGRAPHY AND SOME RELATED TECHNIQUES [J].
BARKER, GC .
ANALYTICA CHIMICA ACTA, 1958, 18 (1-2) :118-131
[6]   On the use of digital staircase ramps for linear sweep voltammetry at microdisc electrodes: Large step potentials significantly broaden and shift voltammetric peaks [J].
Barnes, Alexander S. ;
Streeter, Ian ;
Compton, Richard G. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 623 (01) :129-133
[7]   Recent Advances in Voltammetry [J].
Batchelor-McAuley, Christopher ;
Kaetelhoen, Enno ;
Barnes, Edward O. ;
Compton, Richard G. ;
Laborda, Eduardo ;
Molina, Angela .
CHEMISTRYOPEN, 2015, 4 (03) :224-260
[8]   Applications of Convolution Voltammetry in Electroanalytical Chemistry [J].
Bentley, Cameron L. ;
Bond, Alan M. ;
Hollenkamp, Anthony F. ;
Mahon, Peter J. ;
Zhang, Jie .
ANALYTICAL CHEMISTRY, 2014, 86 (04) :2073-2081
[9]   Advantages Available in the Application of the Semi-Integral Electroanalysis Technique for the Determination of Diffusion Coefficients in the Highly Viscous Ionic Liquid 1-Methyl-3-Octylimidazolium Hexafluorophosphate [J].
Bentley, Cameron L. ;
Bond, Alan M. ;
Hollenkamp, Anthony F. ;
Mahon, Peter J. ;
Zhang, Jie .
ANALYTICAL CHEMISTRY, 2013, 85 (04) :2239-2245
[10]   COMPARISON OF LINEAR SCAN AND STAIRCASE VOLTAMMETRY - EXPERIMENTAL RESULTS [J].
BILEWICZ, R ;
OSTERYOUNG, RA ;
OSTERYOUNG, J .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2761-2765