Approximating anatomically-guided PET reconstruction in image space using a convolutional neural network

被引:38
作者
Schramm, Georg [1 ]
Rigie, David [2 ,3 ]
Vahle, Thomas [4 ]
Rezaei, Ahmadreza [1 ]
Van Laere, Koen [1 ]
Shepherd, Timothy [5 ]
Nuyts, Johan [1 ]
Boada, Fernando [2 ,3 ]
机构
[1] KU UZ Leuven, Div Nucl Med, Dept Imaging & Pathol, Leuven, Belgium
[2] NYU, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, Nyc, NY USA
[3] NYU, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, Nyc, NY USA
[4] Siemens Healthcare GmbH, Erlangen, Germany
[5] NYU, Sch Med, Dept Neuroradiol, Dept Radiol,NYU Langone Hlth, New York, NY USA
关键词
Molecular imaging; Magnetic resonance imaging; Image reconstruction; Quantification; Machine learning; PARTIAL-VOLUME CORRECTION; EMISSION-TOMOGRAPHY; INFORMATION; PRIORS;
D O I
10.1016/j.neuroimage.2020.117399
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In the last two decades, it has been shown that anatomically-guided PET reconstruction can lead to improved bias-noise characteristics in brain PET imaging. However, despite promising results in simulations and first studies, anatomically-guided PET reconstructions are not yet available for use in routine clinical because of several reasons. In light of this, we investigate whether the improvements of anatomically-guided PET reconstruction methods can be achieved entirely in the image domain with a convolutional neural network (CNN). An entirely image-based CNN post-reconstruction approach has the advantage that no access to PET raw data is needed and, moreover, that the prediction times of trained CNNs are extremely fast on state of the art GPUs which will substantially facilitate the evaluation, fine-tuning and application of anatomically-guided PET reconstruction in real-world clinical settings. In this work, we demonstrate that anatomically-guided PET reconstruction using the asymmetric Bowsher prior can be well-approximated by a purely shift-invariant convolutional neural network in image space allowing the generation of anatomically-guided PET images in almost real-time. We show that by applying dedicated data augmentation techniques in the training phase, in which 16 [F-18]FDG and 10 [(18) F]PE2I data sets were used, lead to a CNN that is robust against the used PET tracer, the noise level of the input PET images and the input MRI contrast. A detailed analysis of our CNN in 36 [F-18]FDG, 18 [(18) F]PE2I, and 7 [(18) F]FET test data sets demonstrates that the image quality of our trained CNN is very close to the one of the target reconstructions in terms of regional mean recovery and regional structural similarity.
引用
收藏
页数:11
相关论文
共 43 条
[1]  
Abadi M, 2016, PROCEEDINGS OF OSDI'16: 12TH USENIX SYMPOSIUM ON OPERATING SYSTEMS DESIGN AND IMPLEMENTATION, P265
[2]   Anatomical-based FDG-PET reconstruction for the detection of hypo-metabolic regions in epilepsy [J].
Baete, K ;
Nuyts, J ;
Van Paesschen, W ;
Suetens, P ;
Dupont, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (04) :510-519
[3]   MR-Guided Kernel EM Reconstruction for Reduced Dose PET Imaging [J].
Bland, James ;
Mehranian, Abolfazl ;
Belzunce, Martin A. ;
Ellis, Sam ;
McGinnity, Colm J. ;
Hammers, Alexander ;
Reader, Andrew J. .
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (03) :235-243
[4]  
Bowsher JE, 2004, IEEE NUCL SCI CONF R, P2488
[5]   Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies [J].
Burgos, Ninon ;
Cardoso, M. Jorge ;
Thielemans, Kris ;
Modat, Marc ;
Pedemonte, Stefano ;
Dickson, John ;
Barnes, Anna ;
Ahmed, Rebekah ;
Mahoney, Colin J. ;
Schott, Jonathan M. ;
Duncan, John S. ;
Atkinson, David ;
Arridge, Simon R. ;
Hutton, Brian F. ;
Ourselin, Sebastien .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (12) :2332-2341
[6]   Ultra-Low-Dose 18F-Florbetaben Amyloid PET Imaging Using Deep Learning with Multi-Contrast MRI Inputs [J].
Chen, Kevin T. ;
Gong, Enhao ;
Macruz, Fabiola Bezerra de Carvalho ;
Xu, Junshen ;
Boumis, Athanasia ;
Khalighi, Mehdi ;
Poston, Kathleen L. ;
Sha, Sharon J. ;
Greicius, Michael D. ;
Mormino, Elizabeth ;
Pauly, John M. ;
Srinivas, Shyam ;
Zaharchuk, Greg .
RADIOLOGY, 2019, 290 (03) :649-656
[7]   Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels [J].
Comtat, C ;
Kinahan, PE ;
Fessler, JA ;
Beyer, T ;
Townsend, DW ;
Defrise, M ;
Michel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) :1-20
[8]   Deep reconstruction model for dynamic PET images [J].
Cui, Jianan ;
Liu, Xin ;
Wang, Yile ;
Liu, Huafeng .
PLOS ONE, 2017, 12 (09)
[9]   Distance-driven projection and backprojection in three dimensions [J].
De Man, B ;
Basu, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2463-2475
[10]  
Delso G, 2011, J NUCL MED, V52, P1914, DOI 10.2967/jnumed.111.092726