Liquid Chromatography-Tandem Mass Spectrometry Analysis of Folate and Folate Catabolites in Human Serum

被引:68
|
作者
Hannisdal, Rita [1 ,2 ]
Ueland, Per Magne [1 ,2 ,3 ]
Svardal, Asbjorn [1 ,2 ]
机构
[1] Univ Bergen, Inst Med, Pharmacol Sect, N-5021 Bergen, Norway
[2] Univ Bergen, LOCUS Homocysteine & Related Vitamins, N-5021 Bergen, Norway
[3] Haukeland Hosp, N-5021 Bergen, Norway
关键词
FOLIC-ACID SUPPLEMENTATION; NEURAL-TUBE DEFECTS; WHOLE-BLOOD FOLATE; 5-METHYLTETRAHYDROFOLIC ACID; HUMAN PLASMA; QUANTITATIVE-ANALYSIS; MICROBIOLOGIC ASSAY; DISEASE; HOMOCYSTEINE; URINE;
D O I
10.1373/clinchem.2008.114389
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Folate status is associated with several chronic diseases; thus accurate assessment of folate status has become important in the clinical setting and in epidemiological studies. The diversity of folate forms complicates the task of assaying endogenous folate. We developed and validated an assay that measures various forms of folate in addition to folate catabolites in human serum. METHODS: We added ascorbic acid to serum samples from 168 healthy blood donors and 39 patients with renal failure, and precipitated the proteins with acetonitrile containing C-13-labeled folate forms as internal standards. The supernatant was evaporated and the analytes redissolved in water. We then used liquid chromatography-tandem mass spectrometry to quantify 5-methyltetrahydrofolate (5mTHF), 4-alpha-hydroxy-5-methyltetrahydrofolate (hmTHF), folic acid (FA), 5-formyltrahydrofolate (5fTHF), p-aminobenzoylglutamate (pABG), and p-acetamidobenzoylglutamate (apABG). RESULTS: Detection limits were 0.07-0.52 nmol/L, and the assay was linear to 140 nmol/L for all analytes. The mean serum folate concentration from 168 blood donors was 22.7 nmol/L, of which 85.8% was 5mTHF, 12.1% hmTHF, 2.1% FA, and 0.0% 5fTHF. In the same individuals, the mean concentrations of pABG and apABG were 0.07 nmol/L and 0.47 nmol/L, respectively. The concentrations of folate catabolites were 22-30 times higher in 39 patients with renal failure. This folate assay correlated well with the microbiologic assay (r(2) = 0.92) and with measurement of serum folate as pABG equivalents (r(2) = 0.93). CONCLUSIONS: This method based on liquid chromatography-tandem mass spectrometry measures the most abundant folate species and 2 folate catabolites in human serum. (C) 2008 American Association for Clinical Chemistry
引用
收藏
页码:1147 / 1154
页数:8
相关论文
共 50 条
  • [21] Simultaneous measurement of folate cycle intermediates in different biological matrices using liquid chromatography-tandem mass spectrometry
    Nandania, Jatin
    Kokkonen, Meri
    Euro, Liliya
    Velagapudi, Vidya
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 168 - 178
  • [22] Analysis of Perchlorate in Human Saliva by Liquid Chromatography-Tandem Mass Spectrometry
    Oldi, John F.
    Kannan, Kurunthachalam
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (01) : 142 - 147
  • [23] Erythrocyte folate extraction and quantitative determination by liquid chromatography-tandem mass spectrometry: Comparison of results with microbiologic assay
    Fazili, Z
    Pfeiffer, CM
    Zhang, M
    Jain, R
    CLINICAL CHEMISTRY, 2005, 51 (12) : 2318 - 2325
  • [24] Application of stable isotope dilution assays based on liquid chromatography-tandem mass spectrometry for the assessment of folate bioavailability
    Rychlik, M
    Netzel, M
    Pfannebecker, I
    Frank, T
    Bitsch, I
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 167 - 176
  • [25] Mucopolysaccharides quantitation in serum by liquid chromatography-tandem mass spectrometry
    Raymond, Kimiyo
    Lacey, Jean M.
    Dimitar, Gavrilov
    Matern, Dietrich
    Oglesbee, Devin
    Rinaldo, Piero
    Tortorelli, Silvia
    MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S123 - S123
  • [26] Determination of serum amantadine by liquid chromatography-tandem mass spectrometry
    Arndt, T
    Guessregen, B
    Hohl, A
    Reis, J
    CLINICA CHIMICA ACTA, 2005, 359 (1-2) : 125 - 131
  • [27] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01): : 50 - 57
  • [28] Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 113 - 118
  • [29] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [30] Analysis of acrylamide in different foodstuffs using liquid chromatography-tandem mass spectrometry and gas chromatography-tandem mass spectrometry
    Hoenicke, K
    Gatermann, R
    Harder, W
    Hartig, L
    ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 207 - 215