Reverse total shoulder arthroplasty component center of rotation affects muscle function

被引:38
|
作者
Hoenecke, Heinz R., Jr. [1 ]
Flores-Hernandez, Cesar [2 ]
D'Lima, Darryl D. [2 ]
机构
[1] Scripps Clin, Div Orthopaed Surg, La Jolla, CA 92037 USA
[2] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
Shoulder arthroplasty; reverse shoulder arthroplasty; glenosphere; deltoid function; glenohumeral forces; shoulder biomechanics; CUFF DEFICIENCY; PROSTHESIS; IMPINGEMENT; ARTHRITIS; ABDUCTION; DESIGN; MOTION; RANGE;
D O I
10.1016/j.jse.2013.11.025
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Medialization of the glenohumeral center of rotation alters the moment arm of the deltoid, can affect muscle function, and increases the risk for scapular notching due to impingement. The objective of this study was to determine the effect of position of the glenosphere on deltoid efficiency and the range of glenohumeral adduction. Methods: Scapulohumeral bone models were reconstructed from computed tomography scans and virtually implanted with primary or reverse total shoulder arthroplasty implants. The placement of the glenosphere was varied to simulate differing degrees of "medialization'' and inferior placement relative to the glenoid. Muscle and joint forces were computed during shoulder abduction in OpenSim musculoskeletal modeling software. Results: The average glenohumeral joint reaction forces for the primary total shoulder arthroplasty were within 5% of those previously reported in vivo. Superior placement or full lateralization of the glenosphere increased glenohumeral joint reaction forces by 10% and 18%, respectively, relative to the recommended reverse total shoulder arthroplasty position. The moment arm of the deltoid muscle was the highest at the recommended baseline surgical position. The baseline glenosphere position resulted in a glenohumeral adduction deficit averaging more than 10 degrees that increased to more than 25 degrees when the glenosphere was placed superiorly. Only with full lateralization was glenohumeral adduction unaffected by superoinferior placement. Discussion/Conclusion: Selecting optimum placement of the glenosphere involves tradeoffs in bending moment at the implant-bone interface, risk for impingement, and deltoid efficiency. A viable option is partially medializing the glenosphere, which retains most of the benefits of deltoid efficiency and reduces the risk for scapular notching. (C) 2014 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1128 / 1135
页数:8
相关论文
共 50 条
  • [21] Computer-assisted analysis of functional internal rotation after reverse total shoulder arthroplasty: implications for component choice and orientation
    Hochreiter, Bettina
    Meisterhans, Michel
    Zindel, Christoph
    Calek, Anna-Katharina
    Gerber, Christian
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [22] Effect of humeral component version on impingement in reverse total shoulder arthroplasty
    Stephenson, Daniel R.
    Oh, Joo Han
    McGarry, Michelle H.
    Hatch, George F. Rick, III
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (04) : 652 - 658
  • [23] Effects of glenosphere positioning on impingement-free internal and external rotation after reverse total shoulder arthroplasty
    Li, Xinning
    Knutson, Zakary
    Choi, Daniel
    Lobatto, Daniel
    Lipman, Joseph
    Craig, Edward V.
    Warren, Russell F.
    Gulotta, Lawrence V.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (06) : 807 - 813
  • [24] Intraoperative measurements of reverse total shoulder arthroplasty contact forces
    Farmer, Kevin W.
    Higa, Masaru
    Banks, Scott A.
    Chang, Chih-Chiang
    Struk, Aimee M.
    Wright, Thomas W.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
  • [25] Reverse Total Shoulder Arthroplasty Biomechanical Considerations and the Concept of Lateralization
    Luthringer, Tyler A.
    Larose, Gabriel
    Kwon, Young
    Zuckerman, Joseph D.
    Virk, Mandeep S.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2022, 80 (01): : 65 - 74
  • [26] Reverse total shoulder arthroplasty for cuff tear arthropathy: the clinical effect of deltoid lengthening and center of rotation medialization
    Jobin, Charles M.
    Brown, Gabriel D.
    Bahu, Maher J.
    Gardner, Thomas R.
    Bigliani, Louis U.
    Levine, William N.
    Ahmad, Christopher S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (10) : 1269 - 1277
  • [27] Inferior tilt fixation of the glenoid component in reverse total shoulder arthroplasty: A biomechanical study
    Chae, S. W.
    Lee, J.
    Han, S. H.
    Kim, S-Y.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (04) : 421 - 425
  • [28] Outcomes of an anatomic total shoulder arthroplasty with a contralateral reverse total shoulder arthroplasty
    Cox, Ryan M.
    Padegimas, Eric M.
    Abboud, Joseph A.
    Getz, Charles L.
    Lazarus, Mark D.
    Ramsey, Matthew L.
    Williams, Gerald R., Jr.
    Horneff, John G., III
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) : 998 - 1003
  • [29] Medialized versus Lateralized Center of Rotation in Reverse Total Shoulder Arthroplasty: A Systematic Review and Meta-Analysis
    Berton, Alessandra
    Gulotta, Lawrence V.
    Longo, Umile Giuseppe
    De Salvatore, Sergio
    Piergentili, Ilaria
    Bandini, Benedetta
    Lalli, Alberto
    Mathew, Joshua
    Warren, Russell F.
    Denaro, Vincenzo
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [30] Is limited external rotation after reverse shoulder arthroplasty associated with glenoidal notching? An observational study
    Grob, Alexandra
    Bouaicha, Samy
    Germann, Marco
    Germann, Sabra
    Gerber, Christian
    Wieser, Karl
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2021, 16 (04): : 272 - 280