A calibration method for misaligned scanner geometry in cone-beam computed tomography

被引:71
|
作者
Sun, Yi [1 ]
Hou, Ying [1 ]
Zhao, Fengyong [1 ]
Hu, Jiasheng [1 ]
机构
[1] Dalian Univ Technol, Sch Elect & Informat Engn, Dalian 116023, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
geometric misalignment; calibration; cone-beam CT;
D O I
10.1016/j.ndteint.2006.03.002
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Computed tomography (CT) images often suffer from artifacts caused by misaligned scanner geometry of CT system. Calibration and correction must be done before image reconstruction. A method for calibration of misaligned scanner geometry in cone-beam CT with single-circle orbit is proposed. In this method, a four-point phantom is used to estimate a set of parameters that describe the geometry of a cone-beam CT system. It requires only one projection of the phantom, instead of several projections at multi-angles. An analytical formula is derived, which avoids falling into local minimum. In addition, there is no restriction on any one of the geometric parameters. The simulated results are illustrated. It is proved that this method is applicable and efficient for misaligned scanner. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:499 / 513
页数:15
相关论文
共 50 条
  • [1] Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    Noo, F
    Clackdoyle, R
    Mennessier, C
    White, TA
    Roney, TJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3489 - 3508
  • [2] A simple and precise alignment calibration method for cone-beam computed tomography with the verifications
    Shih, Kun-Long
    Jin, David Shih-Chun
    Wang, Yu-Hong
    Tran, Trang Thi Ngoc
    Chen, Jyh-Cheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (06):
  • [3] Iterative geometric calibration in circular cone-beam computed tomography
    Zhang, Feng
    Du, Jianping
    Jiang, Hua
    Li, Lei
    Guan, Min
    Yan, Bin
    OPTIK, 2014, 125 (11): : 2509 - 2514
  • [4] Geometry calibration method for a cone-beam CT system
    Yang, Hongkai
    Kang, Kejun
    Xing, Yuxiang
    MEDICAL PHYSICS, 2017, 44 (05) : 1692 - 1706
  • [5] Measurement of the MTF of a Cone-Beam Breast Computed Tomography Laboratory Scanner
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Lauria, Adele
    Russo, Paolo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3958 - 3964
  • [6] Measurement of the MTF of a Cone-Beam Breast Computed Tomography Laboratory Scanner
    Mettivier, Giovanni
    Russo, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 703 - 713
  • [7] Fast cone-beam computed tomography geometric calibration method based on measuring tools
    Zhang C.
    Huang K.
    Chen H.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (01): : 175 - 182
  • [8] Practical geometric calibration for helical cone-beam industrial computed tomography
    Zhang, Feng
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Jiang, Hua
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 19 - 35
  • [9] Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography
    Kachelriess, Marc
    Berkus, Timo
    Stenner, Philip
    Kalender, Willi A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2546 - 2550
  • [10] Empirical dual energy calibration (EDEC) for cone-beam computed tomography
    Stenner, Philip
    Berkus, Timo
    Kachelriess, Marc
    MEDICAL PHYSICS, 2007, 34 (09) : 3630 - 3641