Detection and determination of CrVI in solution using polyaniline modified quartz crystal electrode

被引:47
作者
Mirmohseni, A [1 ]
Oladegaragoze, A [1 ]
机构
[1] Univ Tabriz, Fac Chem, Dept Appl Chem, Polymer Res Technol Lab, Tabriz, Iran
关键词
conducting polymers; polyaniline; quartz crystal microbalance; heavy metals; chromium (Cr-VI);
D O I
10.1002/app.10746
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Conducting polymers such as polvaniline and polypyrrole exhibit novel sensoric properties and are able to interact chemically or electrochemically with the species of interest for detection. In the current investigation, construction of a sensor based on an electrochemical reaction between Cr-VI and a thin layer of polyaniline, coated at the surface of quartz crystal electrode, is reported. Polyaniline was synthesized, electrochemically, at the surface of quartz crystal electrode. It was then reduced at -0.1 V versus Ag/AgCl. The modified electrode was exposed to various concentrations of Cr-VI solutions ranging from 10(-7) to 10(-1) M. Mass changes of the polymer-modified electrode due to the reaction between Cr-VI and polyaniline was found to be linear, corresponding to the concentration of Cr-VI. The experiments in both acidic and nonacidic conditions were performed. In both conditions, linear double-logarithmic calibration curves of mass change of the polymer film versus Cr-VI concentration were obtained. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:2772 / 2780
页数:9
相关论文
共 31 条
[1]   Reduction of hexavalent chromium by polypyrrole deposited on different carbon substrates [J].
Alatorre, MA ;
Gutierrez, S ;
Paramo, U ;
Ibanez, JG .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1998, 28 (05) :551-557
[2]  
Byrne JP, 1997, CAN J ANAL SCI SPECT, V42, P95
[3]   Calixarene-coated piezoelectric quartz crystal sensor for the detection of organic amine in liquids [J].
Chen, LX ;
He, XW ;
Hu, XB ;
Xu, H .
ANALYST, 1999, 124 (12) :1787-1790
[4]  
Dean J., 1995, Analytical Chemistry Handbook
[5]   Selective detection of aroma components by acoustic wave sensors coated with conducting polymer films [J].
Deng, ZP ;
Stone, DC ;
Thompson, M .
ANALYST, 1996, 121 (05) :671-679
[6]   BIOSENSORS FOR ENVIRONMENTAL MONITORING [J].
DENNISON, MJ ;
TURNER, APF .
BIOTECHNOLOGY ADVANCES, 1995, 13 (01) :1-12
[7]   A polypyrrole-coated, piezoelectric sensor for CrVI.: Preliminary results [J].
Desimoni, E ;
Bassani, I .
ANALYTICAL COMMUNICATIONS, 1999, 36 (02) :45-46
[8]   Electrochemical control of solid phase micro-extraction using unique conducting polymer coated fibers [J].
Gbatu, TP ;
Ceylan, O ;
Sutton, KL ;
Rubinson, JF ;
Galal, A ;
Caruso, JA ;
Mark, HB .
ANALYTICAL COMMUNICATIONS, 1999, 36 (05) :203-205
[9]   Polymeric sensing films: New horizons in sensories? [J].
Harsanyi, G .
MATERIALS CHEMISTRY AND PHYSICS, 1996, 43 (03) :199-203
[10]   ANALYTICAL APPLICATIONS OF CONDUCTING POLYMERS [J].
IVASKA, A .
ELECTROANALYSIS, 1991, 3 (4-5) :247-254