Quantitative determination of melatonin in milk by LC-MS/MS

被引:40
作者
Karunanithi, Duraisamy [1 ,2 ]
Radhakrishna, Ammanamanchi [2 ]
Sivaraman, Kunnummal Parambil [2 ]
Biju, Valsala Madhavan Nair [1 ]
机构
[1] Natl Inst Technol, Dept Chem, Tiruchirappalli 620015, Tamil Nadu, India
[2] Shriram Inst Ind Res, Analyt Sci Div, Bangalore 560048, Karnataka, India
来源
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE | 2014年 / 51卷 / 04期
关键词
Melatonin; 7-D melatonin; LC-MS/MS; Milk; PERFORMANCE LIQUID-CHROMATOGRAPHY; SENSITIVE METHOD; PLASMA; SEROTONIN; SAMPLES; PINEAL; MS;
D O I
10.1007/s13197-013-1221-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A rapid, reliable and sensitive LC-MS/MS method for the determination of melatonin in milk was developed and validated. Sample was extracted with dichloromethane and cleaned by passing through Chem Elut solid phase extraction cartridge. The solvent was evaporated to dryness, reconstituted with methanol and analysed by LC-MS/MS on Agilent zorbax Eclipse XDB C-18 rapid resolution analytical column. The analytical procedure was found to be accurate, precise and linear. The method accuracy was 92.2 % (range 90.06-94.58) and the mean precision was 1.55 % and the calibration was linear for 1 to 150 pg mL(-1) (R-2 > 0.99), the lowest limit of quantification (LLOQ) was 1 pg mL(-1). 7-D Melatonin (7-DM) was used as an internal standard. This method was proved to be a promising method for the determination of melatonin for market milk and human milk samples.
引用
收藏
页码:805 / 812
页数:8
相关论文
共 28 条
[1]   Melatonin as antioxidant, geroprotector and anticarcinogen [J].
Anisimov, Vladimir N. ;
Popovich, Irina G. ;
Zabezhinski, Mark A. ;
Anisimov, Sergey V. ;
Vesnushkin, Georgy M. ;
Vinogradova, Irina A. .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2006, 1757 (5-6) :573-589
[2]  
[Anonymous], 2002, OFF J EUR COMMUN L, pL221
[3]   CIRCADIAN PATTERN OF PLASMA MELATONIN CONCENTRATIONS DURING 4 PHASES OF THE HUMAN MENSTRUAL-CYCLE [J].
BERGA, SL ;
YEN, SSC .
NEUROENDOCRINOLOGY, 1990, 51 (05) :606-612
[4]   Rapid method for accurate analysis of melatonin, serotonin and auxin in plant samples using liquid chromatography-tandem mass spectrometry [J].
Cao, Jin ;
Murch, Susan J. ;
O'Brien, Robert ;
Saxena, Praveen K. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1134 (1-2) :333-337
[5]   Validation of chromatographic methods in biomedical analysis - Viewpoint and discussion [J].
Causon, R .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :175-180
[6]   Determination of melatonin in rat pineal, plasma and retina by high-performance liquid chromatography with electrochemical detection [J].
Chanut, E ;
Nguyen-Legros, J ;
Versaux-Botteri, C ;
Trouvin, JH ;
Launay, JM .
JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (01) :11-18
[7]   Positive and negative electrospray LC-MS-MS methods for quantitation of the antiparasitic endectocide drugs, abamectin, doramectin, emamectin, eprinomectin, ivermectin, moxidectin and selamectin in milk [J].
Durden, David A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :134-146
[8]  
Egoshi K, 2000, NIPPON SHOKUHIN KAGA, V54, P113
[9]   Quantification of melatonin in human saliva by liquid chromatography-tandem mass spectrometry using stable isotope dilution [J].
Eriksson, K ;
Östin, A ;
Levin, JO .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01) :115-123
[10]   A HIGHLY SENSITIVE ASSAY OF MELATONIN AT THE FEMTOGRAM LEVEL IN HUMAN PLASMA BY GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
FOURTILLAN, JB ;
GOBIN, P ;
FAYE, B ;
GIRAULT, J .
BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (08) :499-509