A coded aperture microscope for X-ray fluorescence full-field imaging

被引:3
|
作者
Siddons, D. P. [1 ]
Kuczewski, A. J. [1 ]
Rumaiz, A. K. [1 ]
Tappero, R. [1 ]
Idir, M. [1 ]
Nakhoda, K. [1 ]
Khanfri, J. [2 ]
Singh, V [3 ]
Farquhar, E. R. [4 ]
Sullivan, M. [4 ]
Abel, D. [4 ]
Brady, D. J. [5 ]
Yuan, X. [6 ]
机构
[1] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
[2] SUNY Stony Brook, Stony Brook, NY 11794 USA
[3] Louisiana State Univ, Baton Rouge, LA 70803 USA
[4] Case Western Reserve Univ, Cleveland, OH 44106 USA
[5] Duke Univ, Durham, NC 27708 USA
[6] Nokia Bell Labs, Murray Hill, NJ 07974 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
coded aperture; X-ray microscope; full-field; fluorescence;
D O I
10.1107/S1600577520012308
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 mu m openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 mu m-thick silicon nitride membrane. The gold is 25 mu m thick, offering good contrast up to 20keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.
引用
收藏
页码:1703 / 1706
页数:4
相关论文
共 50 条
  • [1] Full-field x-ray fluorescence imaging using a Fresnel zone plate coded aperture
    Soltau, Jakob
    Meyer, Paul
    Hartmann, Robert
    Strueder, Lothar
    Soltau, Heike
    Salditt, Tim
    OPTICA, 2023, 10 (01): : 127 - 133
  • [2] Full-field x-ray fluorescence imaging microscope with a Wolter mirror
    Takeuchi, A
    Aoki, S
    Yamamoto, K
    Takano, H
    Watanabe, N
    Ando, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1279 - 1285
  • [3] On the way to full-field X-ray fluorescence spectroscopy imaging with coded apertures
    Kulow, Anico
    Buzanich, Ana Guilherme
    Reinholz, Uwe
    Streli, Christina
    Radtke, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (02) : 347 - 356
  • [4] Three-dimensional X-ray fluorescence imaging with confocal full-field X-ray microscope
    Takeuchi, Akihisa
    Terada, Yasuko
    Uesugi, Kentaro
    Suzuki, Yoshio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 616 (2-3): : 261 - 265
  • [5] Full-field X-ray fluorescence imaging with a straight polycapillary X-ray collimator
    An, S.
    Krapohl, D.
    Norlin, B.
    Thungstrom, G.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (12)
  • [6] Full-field X-ray fluorescence microscope with a quasi-monochromatic beam
    Ohigashi, T
    Watanabe, N
    Yokosuka, H
    Aoki, S
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 53 - 56
  • [7] Confocal full-field X-ray microscope for novel three-dimensional X-ray imaging
    Takeuchi, Akihisa
    Terada, Yasuko
    Suzuki, Yoshio
    Uesugi, Kentaro
    Aoki, Sadao
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 616 - 621
  • [8] Trace element mapping of a biological specimen by a full-field X-ray fluorescence imaging microscope with a Wolter mirror
    Hoshino, Masato
    Yamada, Norimitsu
    Ishino, Toyoaki
    Namiki, Takashi
    Watanabe, Norio
    Aoki, Sadao
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1283 - +
  • [9] Time-lapse observation of electrolysis of copper sulfate with a full-field X-ray fluorescence imaging microscope
    Ohigashi, Takuji
    Aota, Tatsuya
    Watanabe, Norio
    Takano, Hidekazu
    Yokosuka, Hiroki
    Aoki, Sadao
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (06) : 4742 - 4745
  • [10] Expanding a polarized synchrotron beam for full-field x-ray fluorescence imaging
    Zhao, Wenyang
    Hirano, Keiichi
    Sakurai, Kenji
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11):