Pelvic and lower extremity veins: Contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience

被引:68
作者
Ruehm, SG [1 ]
Wiesner, W [1 ]
Debatin, JF [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, Zurich, Switzerland
关键词
extremities; MR; magnetic resonance (MR); comparative studies; vascular studies; veins; abnormalities; venography;
D O I
10.1148/radiology.215.2.r00ap27421
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the performance of three-dimensional (3D) magnetic resonance (MR) venography of the pelvis and lower extremities in patients without acute deep venous thrombosis by using a lower extremity vascular coil and pedal injection of paramagnetic contrast material. MATERIALS AND METHODS: Conventional and MR venography were performed in 35 legs in 25 patients referred for evaluation of varicosities (n = 8) and postthrombotic changes (n = 7) and assessment of the great saphenous veins prior to bypass surgery (n = 10). Injection of 120 mL of diluted (1:15) gadopentetate dimeglumine into a pedal vein was performed manually at a rate of 1 mL/sec, and 3D gradient-recalled echo data sets of the upper and lower veins were collected. Conventional and MR venographic images were analyzed separately in a blinded fashion. RESULTS: MR image quality was comparable to that of conventional venograms. Varicose changes of the great and small saphenous Veins (sensitivity, 94% [44 of 47]; specificity, 96% [89 of 93]) were assessed as reliably as their status before bypass surgery:(sensitivity, 98% [53 of 54]; specificity, 92% [47 of 51]). Postthrombotic change!; were diagnosed with a sensitivity of 100% [13 of 13] and a specificity of 98% [88 of 90]. CONCLUSION: Direct 3D MR venography comprehensively displays the lower extremity venous system and permits assessment of postthrombotic and varicose changer; and the bypass suitability of the saphenous vein.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 28 条
[1]   Renal artery stenosis and accessory renal arteries:: Accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography [J].
Bakker, J ;
Beek, FJA ;
Beutler, JJ ;
Hené, RJ ;
de Kort, GAP ;
de Lange, EE ;
Moons, KGM ;
Mali, WPTM .
RADIOLOGY, 1998, 207 (02) :497-504
[2]   CONTRAST VENOGRAPHY OF THE LEG - DIAGNOSTIC EFFICACY, TOLERANCE, AND COMPLICATION RATES WITH IONIC AND NONIONIC CONTRAST-MEDIA [J].
BETTMANN, MA ;
ROBBINS, A ;
BRAUN, SD ;
WETZNER, S ;
DUNNICK, NR ;
FINKELSTEIN, J .
RADIOLOGY, 1987, 165 (01) :113-116
[3]   Magnetic resonance angiography of the aortic arch [J].
Carpenter, JP ;
Holland, GA ;
Golden, MA ;
Barker, CF ;
Lexa, FJ ;
Gilfeather, M ;
Schnall, MD .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (01) :145-151
[4]   3D gadolinium-enhanced MR angiography of the carotid arteries [J].
Cloft, HJ ;
Murphy, KJ ;
Prince, MR ;
Brunberg, JA .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :593-600
[5]   DEEP VENOUS THROMBOSIS OF EXTREMITIES - ROLE OF MR IMAGING IN THE DIAGNOSIS [J].
ERDMAN, WA ;
JAYSON, HT ;
REDMAN, HC ;
MILLER, GL ;
PARKEY, RW ;
PESHOCK, RW .
RADIOLOGY, 1990, 174 (02) :425-431
[6]   VENOUS THROMBOSIS - CLINICAL AND EXPERIMENTAL MR IMAGING [J].
ERDMAN, WA ;
WEINREB, JC ;
COHEN, JM ;
BUJA, LM ;
CHANEY, C ;
PESHOCK, RM .
RADIOLOGY, 1986, 161 (01) :233-238
[7]   DETECTION OF DEEP VENOUS THROMBOSIS - PROSPECTIVE COMPARISON OF MR-IMAGING WITH CONTRAST VENOGRAPHY [J].
EVANS, AJ ;
SOSTMAN, HD ;
KNELSON, MH ;
SPRITZER, CE ;
NEWMAN, GE ;
PAINE, SS ;
BEAM, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :131-139
[8]  
Flamm S D, 1996, Magn Reson Imaging Clin N Am, V4, P217
[9]   Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels [J].
Gilfeather, M ;
Holland, GA ;
Siegelman, ES ;
Schanll, MD ;
Axel, L ;
Carpenter, JP ;
Golden, MA .
RADIOGRAPHICS, 1997, 17 (02) :423-432
[10]   Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography [J].
Hany, TF ;
Debatin, JF ;
Leung, DA ;
Pfammatter, T .
RADIOLOGY, 1997, 204 (02) :357-362