Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 tesla

被引:57
作者
Klumpp, Bernhard [1 ]
Fenchel, Michael [1 ]
Hoevelborn, Tobias [1 ]
Helber, Uwe [1 ]
Scheule, Albertus [1 ]
Claussen, Claus [1 ]
Miller, Stephan [1 ]
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
关键词
myocardial viability; delayed enhancement; myocardial infarction; high field magnetic resonance imaging; contrast media; 3.0; T;
D O I
10.1097/01.rli.0000233321.82194.09
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in TI-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on strong T I-weighting and imaging after contrast material administration. The aim of this study was to compare cardiac delayed enhancement (DE) MRI at 3.0 T and 1.5 T with respect to image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between infarcted and normal myocardium. Materials and Methods: Forty consecutive patients with history of myocardial infarction were examined at 3.0 T (n = 20) or at 1.5 T (n = 20). Myocardial function was assessed using cine steady-statefree-precession (SSFP) sequences (TR 3.1 milliseconds, TE 1.6 milliseconds, flip angle 70', and a matrix of 168 X 256 at 1.5 T and TR 3.4 milliseconds, TE 1.7 milliseconds, flip angle 50 degrees and a matrix of 168 X 256 at 3.0 T), acquired in long- and short-axes views. DE images were obtained 15 minutes after the administration of 0.15 mmol of Gd-DTPA/kg body weight using a segmented inversion recovery prepared gradient echo sequence at 1.5 T (TR 9.6 milliseconds, TE 4.4 milliseconds, flip angle 25 degrees, matrix 160 X 256, bandwidth 140 Hertz/pixel) and at 3.0 T (TR 9.8 milliseconds, TE 4.3 milliseconds, flip angle 30 degrees, matrix 150 X 256, bandwidth 140 Hertz/pixel). For image analysis, standardized SNR and CNR measurements were performed in infarcted and remote myocardial regions. Two independent observers rated image quality on a 4-point scale (0 = poor image quality,1 = sufficient image quality, 2 good image quality, 3 = excellent image quality). Results: High diagnostic image quality was obtained in all patients. Rating of mean image quality was 2.2 +/- 0.8 at 1.5 T and 2.5 +/- 0.6 at 3.0 T (P = 0.012) for observer I and 2.2 +/- 0.7 at 1.5 T and 2.6 +/- 0.6 at 3.0 T (P = 0.003) for observer 2, respectively. Interobserver agreement was good (K = 0.68 at 1.5 T and 0.78 at 3.0 T). SNR measurements yielded a mean SNR of 37.8 +/- 13.9/22.9 +/- 6.0 in infarcted myocardium (P < 0.001) and 5.6 +/- 2.2/5.9 +/- 2.4 in normal myocardium (P = 0.45) at 3.0 T/1.5 T, respectively. CNR measurements revealed mean values of 32.4 +/- 13.0/16.7 +/- 5.4 (P < 0.001) at 3.0 T/1.5 T, respectively. Conclusions: Delayed enhancement MRI at 3.0 T is feasible and provides superior image quality compared with 1.5 T. Furthermore, using identical contrast doses, increased SNR and CNR values were recorded at 3.0 T.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 34 条
[1]  
[Anonymous], 2004, HEART DIS STROK STAT
[2]   Comparison of late enhancement cardiovascular magnetic resonance and thallium SPECT in patients with coronary disease and left ventricular dysfunction [J].
Ansari, M ;
Araoz, PA ;
Gerard, SK ;
Watzinger, N ;
Lund, GK ;
Massie, BM ;
Higgins, CB ;
Saloner, DA .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (02) :549-556
[3]   RECURRENCE OF ANGINA AFTER CORONARY-ARTERY BYPASS-SURGERY - PREDICTORS AND PROGNOSIS (CASS REGISTRY) [J].
CAMERON, AAC ;
DAVIS, KB ;
ROGERS, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (04) :895-899
[4]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[5]   STRUCTURAL AND METABOLIC CORRELATES OF THE REVERSIBILITY OF CHRONIC LEFT-VENTRICULAR ISCHEMIC DYSFUNCTION IN HUMANS [J].
DEPRE, C ;
VANOVERSCHELDE, JLJ ;
MELIN, JA ;
BORGERS, M ;
BOL, A ;
AUSMA, J ;
DION, R ;
WIJNS, W .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (03) :H1265-H1275
[6]   Contrast-enhanced magnetic resonance imaging of myocardium at risk - Distinction between reversible and irreversible injury throughout infarct healing [J].
Fieno, DS ;
Kim, RJ ;
Chen, EL ;
Lomasney, JW ;
Klocke, FJ ;
Judd, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (06) :1985-1991
[7]   Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T [J].
Greenman, RL ;
Shirosky, JE ;
Mulkern, RV ;
Rofsky, NM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (06) :648-655
[8]   Comprehensive cardiac magnetic resonance imaging at 3.0 tesla - Feasibility and implications for clinical applications [J].
Gutberlet, M ;
Noeske, R ;
Schwinge, K ;
Freyhardt, P ;
Felix, R ;
Niendorf, T .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :154-167
[9]   Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging:: comparison of 1.5 T vs. 3.0 T [J].
Gutberlet, M ;
Schwinge, K ;
Freyhardt, P ;
Spors, B ;
Grothoff, M ;
Denecke, T ;
Lüdemann, L ;
Noeske, R ;
Niendorf, T ;
Felix, R .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1586-1597
[10]   QUANTITATION OF HUMAN LEFT-VENTRICULAR MASS - AND VOLUME BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY - INVITRO ANATOMIC VALIDATION [J].
HELAK, JW ;
REICHEK, N .
CIRCULATION, 1981, 63 (06) :1398-1407