IMPACT OF ENCAPSULATION ON IN VITRO AND IN VIVO PERFORMANCE OF VOLATILE NANOSCALE PHASE-SHIFT PERFLUOROCARBON DROPLETS

被引:26
作者
Yoo, Kimoon [1 ]
Walker, Wesley R. [1 ]
Williams, Ross [1 ]
Tremblay-Darveau, Charles [1 ,2 ]
Burns, Peter N. [1 ,2 ]
Sheeran, Paul S. [1 ,2 ]
机构
[1] Sunnybrook Res Inst, Phys Sci, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Perfluorocarbon; Ultrasound contrast agents; Phase-shift droplets; Acoustic droplet vaporization; Singular value decomposition; Droplet circulation time; Droplet half-life; CONTRAST-ENHANCED ULTRASOUND; DRUG-DELIVERY; SIZE DISTRIBUTION; AGENTS; MICROBUBBLES; VAPORIZATION; NANOPARTICLES; DEFINITY(TM); BEHAVIOR; DOPPLER;
D O I
10.1016/j.ultrasmedbio.2018.04.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Phase-shift droplets can be converted by sound from low-echogenicity, liquid-core agents into highly echogenic microbubbles. Many proposed applications in imaging and therapy take advantage of the high spatiotemporal control over this dynamic transition. Although some studies have reported increased circulation time of the droplets compared with microbubbles, few have directly explored the impact of encapsulation on droplet performance. With the goal of developing nanoscale droplets with increased circulatory persistence, we first evaluate the half-life of several candidate phospholipid encapsulations in vitro at clinical frequencies. To evaluate in vivo circulatory persistence, we develop a technique to periodically measure droplet vaporization from high-frequency B-mode scans of a mouse kidney. Results show that longer acyl chain phospholipids can dramatically reduce droplet degradation, increasing median half-life in vitro to 25.6 min-a 50-fold increase over droplets formed from phospholipids commonly used for clinical microbubbles. In vivo, the best-performing droplet formulations showed a median half-life of 18.4 min, more than a 35-fold increase in circulatory half-life compared with microbubbles with the same encapsulation in vivo. These findings also point to possible refinements that may improve nanoscale phase-shift droplet performance beyond those measured here. (E-mail: pssheeran@gmail.com) (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1836 / 1852
页数:17
相关论文
共 55 条
[1]  
Albanese A, 2012, ANNU REV BIOMED ENG, V14, P1, DOI [10.1146/annurev-bioeng-071811-150124, 10.1146/annurev.bioeng-071811-150124]
[2]   GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND [J].
APFEL, RE ;
HOLLAND, CK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :179-185
[3]   Hypervascular Liver Masses on Contrast-Enhanced Ultrasound: The Importance of Washout [J].
Bhayana, Deepak ;
Kim, Tae Kyoung ;
Jang, Hyun-Jung ;
Burns, Peter N. ;
Wilson, Stephanie R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :977-983
[4]   Dissolution behavior of lipid monolayer-coated, air-filled microbubbles: Effect of lipid hydrophobic chain length [J].
Borden, MA ;
Longo, ML .
LANGMUIR, 2002, 18 (24) :9225-9233
[5]   Unbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators [J].
Candes, Emmanuel J. ;
Sing-Long, Carlos A. ;
Trzasko, Joshua D. .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2013, 61 (19) :4643-4657
[6]   Ultrasound internal tattooing [J].
Couture, Olivier ;
Faivre, Magalie ;
Pannacci, Nicolas ;
Babataheri, Avin ;
Servois, Vincent ;
Tabeling, Patrick ;
Tanter, Mickael .
MEDICAL PHYSICS, 2011, 38 (02) :1116-1123
[7]   Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation [J].
Daeichin, Verya ;
van Rooij, Tom ;
Skachkov, Ilya ;
Ergin, Bulent ;
Specht, Patricia A. C. ;
Lima, Alexandre ;
Ince, Can ;
Bosch, Johan G. ;
van der Steen, Antonius F. W. ;
de Jong, Nico ;
Kooiman, Klazina .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (03) :555-567
[8]   Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity [J].
Demene, Charlie ;
Deffieux, Thomas ;
Pernot, Mathieu ;
Osmanski, Bruno-Felix ;
Biran, Valerie ;
Gennisson, Jean-Luc ;
Sieu, Lim-Anna ;
Bergel, Antoine ;
Franqui, Stephanie ;
Correas, Jean-Michel ;
Cohen, Ivan ;
Baud, Olivier ;
Tanter, Mickael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) :2271-2285
[9]   Contrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images [J].
Desailly, Yann ;
Tissier, Anne-Marie ;
Correas, Jean-Michel ;
Wintzenrieth, Frederic ;
Tanter, Mickael ;
Couture, Olivier .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01) :31-42
[10]   Ultrasound microbubble contrast agents: Fundamentals and application to gene and drug delivery [J].
Ferrara, Katherine ;
Pollard, Rachel ;
Borden, Mark .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2007, 9 :415-447