Study on pollution flashover characteristic of insulators on 500kV AC transmission lines in high-altitude area

被引:1
作者
Huang, Ruiping [1 ]
Zhou, Jun [1 ]
Xu, Yueneng [1 ]
机构
[1] China Elect Power Res Inst, 15 Xiaoying Rd, Beijing 100192, Peoples R China
来源
JOURNAL OF ENGINEERING-JOE | 2019年 / 16期
关键词
flashover; power transmission lines; insulator testing; insulation; external insulation; Tibet high-altitude test base; Beijing UHVDC test base; flashover voltages; AC transmission line project; pollution flashover characteristics; artificial pollution testing; equivalent salt deposit density; voltage; 500; 0; kV; PERFORMANCE;
D O I
10.1049/joe.2018.8468
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pollution flashover performance of insulators is one of the key factors to be considered in the selection of external insulation for transmission lines at high-altitude areas. In pollution laboratories at Tibet high-altitude test base and Beijing ultra high voltage direct current (UHVDC) test base, artificial pollution tests of insulators adopted in AC 500kV transmission project are performed both in sea-level region and real high-altitude regions, through which flashover voltages at typical equivalent salt deposit density are obtained. The relationship between altitude and flashover voltage is acquired as well.
引用
收藏
页码:3306 / 3309
页数:4
相关论文
共 12 条
  • [1] [Anonymous], 1991, 605071991 IEC
  • [2] PERFORMANCE OF CONTAMINATED INSULATORS TESTED FROM 200 KV TO 1000 KV DC
    COMBER, MG
    NIGBOR, RJ
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1981, 16 (03): : 230 - 234
  • [3] GB/T, 45852004 GBT
  • [4] Guan Z., 2006, EXTERNAL INSULATION
  • [5] Hoch D. A., 1992, 3D Africon Conference. Africon '92 Proceedings (Cat. No.92CH3215), P81, DOI 10.1109/AFRCON.1992.624423
  • [6] Comparison of DC pollution flashover performances of various types of porcelain, glass, and composite insulators
    Jiang, Xingliang
    Yuan, Jihe
    Shu, Lichun
    Zhang, Zhijin
    Hu, Jianlin
    Mao, Feng
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) : 1183 - 1190
  • [7] Li W., 2006, POWER SYST TECHNOL, V30, P15
  • [8] Li W, 2004, G2004035 CEPRI, P10
  • [9] INSULATOR POLLUTION PERFORMANCE AT HIGH-ALTITUDE - MAJOR TRENDS
    MERCURE, HP
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 1461 - 1468
  • [10] ROUND-ROBIN ARTIFICIAL CONTAMINATION TEST ON HIGH-VOLTAGE DC INSULATORS
    NAITO, K
    SCHNEIDER, HM
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) : 1438 - 1442