Intra- and interreader variability of orbital volume quantification using 3D computed tomography for reconstructed orbital fractures

被引:11
作者
de Oliveira, Pedro Gomes [1 ]
da Camara, Catarina Perry [2 ,3 ]
Coelho, Paulo Valejo [1 ,3 ]
机构
[1] Ctr Hosp Lisboa Cent, Dept Maxillofacial Surg, EPE, P-1150199 Lisbon, Portugal
[2] Ctr Hosp Lisboa Cent, Dept Neuroradiol, EPE, P-1150199 Lisbon, Portugal
[3] NOVA Univ Lisbon, Fac Ciencias Med, NOVA Med Sch, Campo Martires Patria 130, P-1169056 Lisbon, Portugal
关键词
Orbital fractures; Facial injuries; Computer-assisted radiographic image interpretation; Enophthalmos; BLOWOUT FRACTURES; ENOPHTHALMOS; FLOOR; MANAGEMENT;
D O I
10.1016/j.jcms.2019.04.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Management of orbital fractures continues to present some difficulties, particularly regarding the prediction of late complications. Radiographic assessment provides a detailed evaluation, but the results lack consistency to be considered a standard factor in the decision-making process. Studies focusing on reliability of post-operative imaging are lacking. Materials and methods: We performed a retrospective study using patients from a major trauma center with unilateral orbital floor fracture who underwent surgery. Using three-dimensional volume assessment software, we performed a volume calculation and determined the intra- and interreader variation by intraclass correlation coefficient analysis. Results: Twenty-four orbits were assessed. Mean orbital volume (SD) was 24.02 (2,43) cm(3) for reader 1 and 24.08 (2,51) cm(3) for reader 2. The intraclass correlation coefficient (95% CI) was 0.95 (0.91-0.98) between readers and 0.96 (0.91-0.98) for intra-reader variability. Normal and reconstructed orbits assessed separately also showed very high correlation coefficient for both intra- and inter-subject variability. Conclusion: Results show an almost perfect agreement of volume assessment between readers. The presence of reconstruction material does not seem to add variability. Although reproducible and reliable, radiological volume assessments have not yet shown a clear correlation with clinical outcomes and postoperative management decisions should be based mainly on clinical findings. (C) 2019 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1060 / 1064
页数:5
相关论文
共 27 条
  • [1] Prediction of enophthalmos by computer-based volume measurement of orbital fractures in a Korean population
    Ahn, Hee Bae
    Ryu, Won Yeol
    Yoo, Kyung Won
    Park, Woo Chan
    Rho, Sae Heun
    Lee, Jin Hwa
    Choi, Sun Seob
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 24 (01) : 36 - 39
  • [2] Relative Difference in Orbital Volume as an Indication for Surgical Reconstruction in Isolated Orbital Floor Fractures
    Alinasab, Babak
    Beckman, Mats O.
    Pansell, Tony
    Abdi, Saber
    Westermark, Anders H.
    Stjarne, Par
    [J]. CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2011, 4 (04) : 203 - 211
  • [3] Interreader variability and predictive value of US descriptions of solid breast masses: Pilot study
    Arger, PH
    Sehgal, CM
    Conant, EF
    Zuckerman, J
    Rowling, SE
    Patton, JA
    [J]. ACADEMIC RADIOLOGY, 2001, 8 (04) : 335 - 342
  • [4] Normal changes in orbital volume during childhood
    Bentley, RP
    Sgouros, S
    Natarajan, K
    Dover, MS
    Hockley, AD
    [J]. JOURNAL OF NEUROSURGERY, 2002, 96 (04) : 742 - 746
  • [5] ORBITAL VOLUME MEASUREMENT IN THE MANAGEMENT OF PURE BLOWOUT FRACTURES OF THE ORBITAL FLOOR
    CHARTERIS, DG
    CHAN, CH
    WHITEHOUSE, RW
    NOBLE, JL
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (02) : 100 - 102
  • [6] Chen Chien-Tzung, 2006, Chang Gung Med J, V29, P251
  • [7] The validity and reliability of computed tomography orbital volume measurements
    Diaconu, Silviu C.
    Dreizin, David
    Uluer, Mehmet
    Mossop, Corey
    Grant, Michael P.
    Nam, Arthur J.
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (09) : 1552 - 1557
  • [8] Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures
    Fan, XQ
    Li, J
    Zhu, J
    Li, HS
    Zhang, DS
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 19 (03) : 207 - 211
  • [9] VOLUME MEASUREMENTS OF NORMAL ORBITAL STRUCTURES BY COMPUTED TOMOGRAPHIC ANALYSIS
    FORBES, G
    GEHRING, DG
    GORMAN, CA
    BRENNAN, MD
    JACKSON, IT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) : 149 - 154
  • [10] Cone-beam computed tomography of the orbit and optic canal volumes
    Friedrich, Reinhard E.
    Bruhn, Marc
    Lohse, Christian
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (09) : 1342 - 1349