Pacemakers and defibrillators: anaesthetic implications

被引:28
作者
Salukhe, TV
Dob, D
Sutton, R
机构
[1] Royal Brompton Hosp, Natl Heart Lung Inst, Pacing & ICD Dept, London SW3 6NP, England
[2] Chelsea & Westminster Hosp, London, England
关键词
equipment; defibrillators; pacemakers;
D O I
10.1093/bja/aeh170
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The assessment and management of a patient who has an implanted cardiac device does require some special attention. Anticipation of behaviour, both of the patient and of the device, is the key to safe management and an uncomplicated procedure. When device interrogation facilities are not available locally, the most important information can be gained from careful history taking, inspection of the patient's device information card and by contacting the pacing clinic that the patient attends. Device manufacturers are also useful sources of information and support, and contact details are available on device identification cards. © The Board of Management and Trustees of the British Journal of Anaesthesia 2004.
引用
收藏
页码:95 / 104
页数:10
相关论文
共 52 条
[1]   Development and prospective validation of a clinical index to predict survival in ambulatory patients referred for cardiac transplant evaluation [J].
Aaronson, KD ;
Schwartz, JS ;
Chen, TM ;
Wong, KL ;
Goin, JE ;
Mancini, DM .
CIRCULATION, 1997, 95 (12) :2660-2667
[2]   Effects of magnetic resonance Imaging on cardiac pacemakers and electrodes [J].
Achenbach, S ;
Moshage, W ;
Diem, B ;
Bieberle, T ;
Schibgilla, V ;
Bachmann, K .
AMERICAN HEART JOURNAL, 1997, 134 (03) :467-473
[3]   THE NASPE BPEG GENERIC PACEMAKER CODE FOR ANTIBRADYARRHYTHMIA AND ADAPTIVE-RATE PACING AND ANTITACHYARRHYTHMIA DEVICES [J].
BERNSTEIN, AD ;
CAMM, AJ ;
FLETCHER, RD ;
GOLD, RD ;
RICKARDS, AF ;
SMYTH, NPD ;
SPIELMAN, SR ;
SUTTON, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04) :794-799
[4]   THE NASPE BPEG DEFIBRILLATOR CODE [J].
BERNSTEIN, AD ;
CAMM, AJ ;
FISHER, JD ;
FLETCHER, RD ;
MEAD, RH ;
NATHAN, AW ;
PARSONNET, V ;
RICKARDS, AF ;
SMYTH, NPD ;
SUTTON, R ;
TARJAN, PP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (09) :1776-1780
[5]  
Blanc JJ, 1997, CIRCULATION, V96, P3273
[6]   EFFECTS OF DUAL-CHAMBER PACING WITH SHORT ATRIOVENTRICULAR DELAY IN DILATED CARDIOMYOPATHY [J].
BRECKER, SJD ;
XIAO, HB ;
SPARROW, J ;
GIBSON, DG .
LANCET, 1992, 340 (8831) :1308-1312
[7]   CLINICAL INTERACTIONS BETWEEN PACEMAKERS AND AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
CALKINS, H ;
BRINKER, J ;
VELTRI, EP ;
GUARNIERI, T ;
LEVINE, JH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :666-673
[8]   INITIAL USE OF A PH TRIGGERED PACEMAKER [J].
CAMMILLI, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (06) :1000-1007
[9]   Dual chamber pacing with optimal AV delay in congestive heart failure -: A randomized study [J].
Capucci, A ;
Romano, S ;
Puglis, A ;
Santini, M ;
Pagani, M ;
Cazzin, R ;
Zanuttini, D ;
Mangiameli, S ;
Moracchini, PV ;
Neri, R ;
De Ciuceis, P ;
Circo, A ;
Cavaglià, S ;
De Seta, F .
EUROPACE, 1999, 1 (03) :174-178
[10]   SEQUENTIAL ATRIOVENTRICULAR PACING IN HEART BLOCK COMPLICATING ACUTE MYOCARDIAL INFARCTION [J].
CHAMBERL.DA ;
VASSAUX, CE ;
KASTOR, JA ;
DESANCTI.RW ;
SANDERS, CA .
NEW ENGLAND JOURNAL OF MEDICINE, 1970, 282 (11) :577-&