Accurate technetium-99 determination using the combination of TEVA resin pretreatment and ICP-MS measurement and its influence on the Tc-99/Cs-137 scaling factor calculation

被引:15
作者
Chen, Lian-Song [1 ]
Wang, Tsing-Hai [1 ]
Hsieh, Yi-Kong [1 ]
Jian, Li-Wei [1 ]
Chen, Wie-Han [1 ]
Tsai, Tsuey-Lin [2 ]
Wang, Chu-Fang [1 ]
机构
[1] Natl Tsing Hua Univ, Hsinchu, Taiwan
[2] Atom Energy Council, Inst Nucl Energy Res, Chem Anal Div, Tao Yuan, Taiwan
关键词
Technetium-99; TEVA; ICP-MS; Scaling factor; Radioactive wastes; ENVIRONMENTAL-SAMPLES; TECHNETIUM; SEPARATION; RADWASTES;
D O I
10.1007/s10967-014-2931-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate determination of technetium-99 (Tc-99) is very important because any overestimation will cause the examined radioactive wastes to be categorized into super C class, which dramatically increases the cost of waste management. Herein, we demonstrated that by adopting the analytical method comprising TEVA resin pretreatment and ICP-MS measurement, the determined Tc-99 concentrations in representative waste stream samples from the Lan-Yu low-level radioactive waste temporary storage site in Taiwan were approximately two orders of magnitude lower than those determined from the beta radiation measurement using a low background liquid scintillation counter. Two important concerns emerged from our results. First, severe interferences from other nuclides residing in the matrix considerably affect the determination of Tc-99, even when a low background liquid scintillation counter was used. Second, the currently used Tc-99/Cs-137 scaling factor should be carefully revised, or it might lead to a considerable overestimation of the Tc-99 concentration.
引用
收藏
页码:1883 / 1889
页数:7
相关论文
共 19 条
[1]  
Bibler NE, 2004, WSRCTR200400196 SAV
[2]   Analysis of I-129 in radwastes by neutron activation [J].
Chao, JH ;
Tseng, CL ;
Lee, CJ ;
Hsia, CC ;
Teng, SP .
APPLIED RADIATION AND ISOTOPES, 1999, 51 (02) :137-143
[3]   Sequential extraction separation for determination of technetium-99 in radwastes by ICP-MS [J].
Chao, JH ;
Tseng, CL ;
Lee, CJ .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 251 (01) :105-112
[4]  
Fowler JR, 1981, DPST81899 E I DUPONT
[5]   99TC/137CS ACTIVITY RATIOS IN RAINWATER SAMPLES COLLECTED IN THE SOUTH OF SPAIN [J].
GARCIALEON, M ;
MANJON, G ;
SANCHEZANGULO, CL .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1993, 20 (01) :49-61
[6]  
Howell RS, 1999, ESHHPT990019 WEST SA
[7]  
IAEA, 2009, NUCL EN SER TECHN RE
[8]  
Jensen M, 2009, P 3 CANUS ROCK MECH
[9]   Comparison of two ICP-MS set-ups for measuring 99Tc in large volume water samples [J].
Keith-Roach, MJ ;
Stürup, S ;
Oughton, DH ;
Dahlgaard, H .
ANALYST, 2002, 127 (01) :70-75
[10]  
Kim SI, 2006, WM06 C FEB 26 MAR 2