Use of Guideline-Directed Medications for Heart Failure Before Cardioverter-Defibrillator Implantation

被引:55
作者
Roth, Gregory A. [1 ,2 ]
Poole, Jeanne E. [1 ]
Zaha, Rebecca [3 ]
Zhou, Weiping [3 ]
Skinner, Jonathan [4 ,5 ]
Morden, Nancy E. [3 ,6 ]
机构
[1] Univ Washington, Div Cardiol, 2301 5th Ave,Suite 600, Seattle, WA 98121 USA
[2] Univ Washington, Inst Hlth Metr & Evaluat, Seattle, WA 98195 USA
[3] Dartmouth Inst Hlth Policy & Clin Practice, Hanover, NH USA
[4] Dartmouth Coll, Dept Econ, Hanover, NH 03755 USA
[5] Geisel Sch Med Dartmouth, Dartmouth Inst Hlth Policy & Clin Practice, Hanover, NH USA
[6] Geisel Sch Med Dartmouth, Dept Community & Family Med, Hanover, NH USA
基金
美国国家卫生研究院;
关键词
defibrillator; heart failure; health services research; PRIMARY PREVENTION; RISK;
D O I
10.1016/j.jacc.2015.12.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Guideline-directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF) is recommended before primary prevention implantable cardioverter-defibrillator (ICD) placement. Adherence to this recommendation and associated outcomes are unknown. OBJECTIVES This study examined the use of GDMT (>= 1 prescription filled for both a renin-angiotensin inhibitor [RAI] and a heart failure-approved beta-blocker [HFBB]) within 90 days before primary prevention ICD placement in patients with HFrEF. METHODS Data from the National Cardiovascular Data Registry ICD Registry were merged with a 40% random sample of Medicare administrative data. Prescription fills for recipients of primary prevention ICD between 2007 and 2011 were examined, analyzing GDMT overall and for each U.S. hospital referral region. We identified characteristics associated with GDMT and the association with 1-year mortality. RESULTS Among 19,733 patients with HFrEF and primary prevention ICD, 61.1% filled any GDMT before implantation. Across hospital referral regions, GDMT was applied in 51% to 71%. The strongest predictors of any GDMT included absence of chronic renal disease or nonsustained ventricular tachycardia, low-income prescription benefits subsidy, and less recent left ventricular ejection fraction evaluation. Patients receiving GDMT versus those without had a lower 1-year mortality rate after ICD implantation (11.1% vs. 16.2%), even after adjustment for comorbidities, left ventricular ejection fraction, and functional heart failure class. CONCLUSIONS Rates of GDMT for HFrEF before primary prevention ICD implantation were low, and failure to achieve GDMT was associated with significantly decreased 1-year survival. (C) 2016 by the American College of Cardiology Foundation.
引用
收藏
页码:1062 / 1069
页数:8
相关论文
共 15 条
  • [1] Survival of Patients Receiving a Primary Prevention Implantable Cardioverter-Defibrillator in Clinical Practice vs Clinical Trials
    Al-Khatib, Sana M.
    Hellkamp, Anne
    Bardy, Gust H.
    Hammill, Stephen
    Hall, W. Jackson
    Mark, Daniel B.
    Anstrom, Kevin J.
    Curtis, Jeptha
    Al-Khalidi, Hussein
    Curtis, Lesley H.
    Heidenreich, Paul
    Peterson, Eric D.
    Sanders, Gillian
    Clapp-Channing, Nancy
    Lee, Kerry L.
    Moss, Arthur J.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 309 (01): : 55 - 62
  • [2] [Anonymous], 2012, CREATION NEW RACE ET
  • [3] Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    Bardy, GH
    Lee, KL
    Mark, DB
    Poole, JE
    Packer, DL
    Boineau, R
    Domanski, M
    Troutman, C
    Anderson, J
    Johnson, G
    McNulty, SE
    Clapp-Channing, N
    Davidson-Ray, LD
    Fraulo, ES
    Fishbein, DP
    Luceri, RM
    Ip, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) : 225 - 237
  • [4] Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.jacc.2008.02.032, 10.1016/j.jacc.2008.05.007, 10.1016/j.hrthm.2008.04.014]
  • [5] Chakeabarti S, 2010, J CARD FAIL, V16, pS53, DOI 10.1016/j.cardfail.2010.04.004
  • [6] Dartmouth Medical School, 1996, The Dartmouth atlas of health care
  • [7] Statin Adherence and Risk of Accidents A Cautionary Tale
    Dormuth, Colin R.
    Patrick, Amanda R.
    Shrank, William H.
    Wright, James M.
    Glynn, Robert J.
    Sutherland, Jenny
    Brookhart, M. Alan
    [J]. CIRCULATION, 2009, 119 (15) : 2051 - 2057
  • [8] Underutilization of β-Blockers in Patients Undergoing Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Procedures
    Hauptman, Paul J.
    Swindle, Jason P.
    Masoudi, Frederick A.
    Burroughs, Thomas E.
    [J]. CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2010, 3 (02): : 204 - 211
  • [9] A validated risk model for 1-year mortality after primary prevention implantable cardioverter defibrillator placement
    Heidenreich, Paul A.
    Tsai, Vivian
    Curtis, Jeptha
    Wang, Yongfei
    Turakhia, Mintu P.
    Masoudi, Frederick A.
    Varosy, Paul D.
    Goldstein, Mary K.
    [J]. AMERICAN HEART JOURNAL, 2015, 170 (02) : 281 - U119
  • [10] 2009 Focused Update Incorporated Into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines Developed in Collaboration With the International Society for Heart and Lung Transplantation
    Hunt, Sharon Ann
    Abraham, William T.
    Chin, Marshall H.
    Feldman, Arthur M.
    Francis, Gary S.
    Ganiats, Theodore G.
    Jessup, Mariell
    Konstam, Marvin A.
    Mancini, Donna M.
    Michl, Keith
    Oates, John A.
    Rahko, Peter S.
    Silver, Marc A.
    Stevenson, Lynne Warner
    Yancy, Clyde W.
    Casey, Donald E.
    Smith, Sidney C., Jr.
    Jacobs, Alice K.
    Buller, Christopher E.
    Creager, Mark A.
    Ettinger, Steven M.
    Krumholz, Harlan M.
    Kushner, Frederick G.
    Lytle, Bruce W.
    Nishimura, Rick A.
    Page, Richard L.
    Tarkington, Lynn G.
    Lewin, John C.
    May, Charlene
    Stewart, Mark D.
    Keller, Sue
    McDougall, Allison
    Brown, Nancy
    Whitman, Gayle R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (15) : E1 - E90