Randomised comparison of Pentax AirwayScope and Glidescope for tracheal intubation in patients with normal airway anatomy

被引:33
作者
Teoh, W. H. L. [1 ]
Shah, M. K. [1 ]
Sia, A. T. H. [1 ]
机构
[1] KK Womens & Childrens Hosp, Dept Womens Anaesthesia, Singapore, Singapore
基金
英国医学研究理事会;
关键词
VIDEO LARYNGOSCOPE; MACINTOSH LARYNGOSCOPE; PERFORATION; SCOPE; VIDEOLARYNGOSCOPE;
D O I
10.1111/j.1365-2044.2009.06032.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
P>We compared intubating characteristics of the Pentax AirwayScope and Glidescope in a randomised controlled trial involving 140 patients. We found significantly shorter intubation times with mean (SD) 21.3 (12.3) vs 30.2 (13.2) s, lower intubating difficulty scores 4.4 (10.4) vs 12.8 (16.3) p < 0.001, and better grade 1 laryngeal views with the Pentax AirwayScope (95.7 vs 81.4%, p = 0.015). Significantly more optimisation manoeuvres were needed to successfully intubate with the Glidescope, with significant inability to align the tip of the tracheal tube with the glottic opening with the Glidescope in 9 (13%) vs no patients, p = 0.013. There was more mucosal bleeding (4 (5.7%) vs 1 (1.4%), p = 0.366), more lip bleeding (3 (4.3%) vs 1 (1.4%), p = 0.620) and significantly more postoperative sorethroat, 13 (18.6%) vs 0, p < 0.001 associated with the Glidescope.
引用
收藏
页码:1125 / 1129
页数:5
相关论文
共 19 条
[1]   Tracheal intubation using a Macintosh laryngoscope or a GlideScope® in 15 patients with cervical-spine immobilization [J].
Agrò, F ;
Barzoi, G ;
Montecchia, F .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) :705-706
[2]   Airway Scope for difficult intubation [J].
Asai, T. ;
Enomoto, Y. ;
Okuda, Y. .
ANAESTHESIA, 2007, 62 (02) :199-199
[3]   Complications associated with the use of the GlideScope® videolaryngoscope [J].
Cooper, Richard M. .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (01) :54-57
[4]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[5]   Perforation of the soft palate using the GlideScope® videolaryngoscope [J].
Cross, Paul ;
Cytryn, Jacalyn ;
Cheng, Kenneth K. .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (07) :588-589
[6]  
Dow WA, 2007, CAN J ANAESTH, V54, P161
[7]   Comparison of the GlideScope® video laryngoscope vs. the intubating laryngeal mask for females with normal airways [J].
Fun, W. L. L. ;
Lim, Y. ;
Teoh, W. H. L. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (06) :486-491
[8]   Airway Scope: early clinical experience in 405 patients [J].
Hirabayashi, Yoshihiro ;
Seo, Norimasa .
JOURNAL OF ANESTHESIA, 2008, 22 (01) :81-85
[9]   Comparison of the Airway Scope®, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation:: a manikin study [J].
Koyama, Y. ;
Inagawa, G. ;
Miyashita, T. ;
Kikuchi, T. ;
Miura, N. ;
Miki, T. ;
Kurihara, R. ;
Kamiya, Y. ;
Goto, T. .
ANAESTHESIA, 2007, 62 (09) :936-939
[10]   Clinical review: Management of difficult airways [J].
Langeron, Olivier ;
Amour, Julien ;
Vivien, Benoit ;
Aubrun, Frederic .
CRITICAL CARE, 2006, 10 (06)