Micromachined array tip for multifocus fiber-based optical coherence tomography

被引:45
作者
Yang, VXD [1 ]
Munce, N
Pekar, J
Gordon, ML
Lo, S
Marcon, NE
Wilson, BC
Vitkin, IA
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[2] St Michaels Hosp, Div Gastroenterol, Toronto, ON M5B 1W8, Canada
关键词
D O I
10.1364/OL.29.001754
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High-resolution optical coherence tomography demands a large detector bandwidth and a high numerical aperture for real-time imaging, which is difficult to achieve over a large imaging depth. To resolve these conflicting requirements we propose a novel multifocus fiber-based optical coherence tomography system with a micromachined array tip. We demonstrate the fabrication of a prototype four-channel tip that maintains a 9-14-mum spot diameter with more than 500 mum of imaging depth. Images of a resolution target and a human tooth were obtained with this tip by use of a four-channel cascaded Michelson fiber-optic interferometer, scanned simultaneously at 8 kHz with geometric power distribution across the four channels. (C) 2004 Optical Society of America.
引用
收藏
页码:1754 / 1756
页数:3
相关论文
共 11 条
  • [1] Full-field optical coherence tomography by two-dimensional heterodyne detection with a pair of CCD cameras
    Akiba, M
    Chan, KP
    Tanno, N
    [J]. OPTICS LETTERS, 2003, 28 (10) : 816 - 818
  • [2] Imaging of hard- and soft-tissue structure in the oral cavity by optical coherence tomography
    Colston, BW
    Everett, MJ
    Da Silva, LB
    Otis, LL
    Stroeve, P
    Nathel, H
    [J]. APPLIED OPTICS, 1998, 37 (16): : 3582 - 3585
  • [3] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [4] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [5] Video-rate three-dimensional optical coherence tomography
    Laubscher, M
    Ducros, M
    Karamata, B
    Lasser, T
    Salathé, R
    [J]. OPTICS EXPRESS, 2002, 10 (09): : 429 - 435
  • [6] Netter F., 2014, ATLAS HUMAN ANATOMY
  • [7] Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror
    Qi, B
    Himmer, AP
    Gordon, LM
    Yang, XDV
    Dickensheets, LD
    Vitkin, IA
    [J]. OPTICS COMMUNICATIONS, 2004, 232 (1-6) : 123 - 128
  • [8] An optical coherence microscope with enhanced resolving power in thick tissue
    Schmitt, JM
    Lee, SL
    Yung, KM
    [J]. OPTICS COMMUNICATIONS, 1997, 142 (4-6) : 203 - 207
  • [9] Thermal-light full-field optical coherence tomography
    Vabre, L
    Dubois, A
    Boccara, AC
    [J]. OPTICS LETTERS, 2002, 27 (07) : 530 - 532
  • [10] Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber
    Wang, YM
    Zhao, YH
    Nelson, JS
    Chen, ZP
    Windeler, RS