High b-value diffusion-weighted MR imaging of normal brain at 3 T

被引:24
作者
Cihangiroglu, Mutlu [1 ]
Ulug, Aziz Muefit [2 ,3 ]
Firat, Zeynep [1 ]
Bayram, Ali [1 ]
Kovanlikaya, Arzu [3 ]
Kovanlikaya, Ilhami [1 ,3 ]
机构
[1] Yeditepe Univ Hosp, Dept Radiol, TR-34752 Istanbul, Turkey
[2] Yeditepe Univ, Sch Engn, Dept Biomed Engn, TR-34755 Istanbul, Turkey
[3] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10065 USA
关键词
b value; DWI; MRI; WHITE-MATTER; ISCHEMIC-STROKE; ACCURACY;
D O I
10.1016/j.ejrad.2007.11.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The purpose of this study was to determine the normative apparent diffusion coefficient (ADC) values at 3 T using high b-value (3000s/mm(2)) diffusion-weighted images (DWI) and compare the signal characteristics of the high b value with standard b-value (1000 s/mm(2)) DWI. Methods: Institutional review board approval was obtained for this prospective study which included 20 volunteers (10 M, 10 F, mean age: 38.7 +/- 14.9) without any known clinical disease or radiological findings. All brain examinations were performed with 3 T MR by using similar parameters of b 1000 and b3000 DWI sequences. DWI and ADC maps were obtained. Signal intensity, noise, signal to noise ratio (SNR), contrast to noise (CNR), contrast ratio (CR), and ADC values of bilateral posterior limb of internal capsule, frontal white matter, parietal gray matter, pons, thalamus, splenium of corpus callosum were measured on b 1000 and b3000 DW images. Results: In all anatomic locations, MR signal intensity, SNR and ADC values of b3000 images were significantly lower than MR signal intensity, SNR and ADC values of b 1000 images (p < 0.001). The CNR and CR values at the posterior limb of internal capsule and pons were significantly increased on b3000 images (p < 0.001) and decreased in the other regions measured. Conclusion: The ADC values calculated from standard b-value DWI were significantly higher than those calculated from high b-value DWI. These results agree with the previous studies. In the regions where CNR values increase with high b value, b3000 DWI images may provide additional clinical information. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 15 条
[1]  
Assaf Y, 2002, J NEUROL SCI, V15, P203
[2]   Normal white matter development from infancy to adulthood: Comparing diffusion tensor and high b value diffusion weighted MR images [J].
Ben Bashat, D ;
Ben Sira, L ;
Graif, M ;
Pianka, P ;
Hendler, T ;
Cohen, Y ;
Assaf, Y .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) :503-511
[3]   High b-value diffusion-weighted MRI of normal brain [J].
Burdette, JH ;
Durden, DD ;
Elster, AD ;
Yen, YF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (04) :515-519
[4]   Acute ischemic stroke:: Accuracy of diffusion-weighted MR imaging -: Effects of b value and cerebrospinal fluid suppression [J].
Chen, PE ;
Simon, JE ;
Hill, MD ;
Sohn, CH ;
Dickhoff, P ;
Morrish, WF ;
Sevick, RJ ;
Frayne, R .
RADIOLOGY, 2006, 238 (01) :232-239
[5]   Diffusion imaging: Insight to cell status and cytoarchitecture [J].
Chenevert, Thomas L. ;
Sundgren, Pia C. ;
Ross, Brian D. .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2006, 16 (04) :619-+
[6]  
DeLano MC, 2000, AM J NEURORADIOL, V21, P1830
[7]   Diffusion-weighted MR imaging sequence in the detection of postoperative recurrent cholesteatoma [J].
Dubrulle, F ;
Souillard, R ;
Chechin, D ;
Vaneecloo, FM ;
Desaulty, A ;
Vincent, C .
RADIOLOGY, 2006, 238 (02) :604-610
[8]   Diffusion-weighted MR imaging:: Diagnostic accuracy in patients imaged within 6 hours of stroke symptom onset [J].
González, RG ;
Schaefer, PW ;
Buonanno, FS ;
Schwamm, LH ;
Budzik, RF ;
Rordorf, G ;
Wang, B ;
Sorensen, AG ;
Koroshetz, WJ .
RADIOLOGY, 1999, 210 (01) :155-162
[9]  
Kim HJ, 2005, AM J NEURORADIOL, V26, P208
[10]  
Meyer JR, 2000, AM J NEURORADIOL, V21, P1821