Noninvasive Keratograph assessment of tear film break-up time and location in patients with age-related cataracts and dry eye syndrome

被引:74
作者
Jiang, Yongxiang [1 ]
Ye, Hongfei [1 ]
Xu, Jianjiang [1 ]
Lu, Yi [1 ]
机构
[1] Fudan Univ, Dept Ophthalmol, Eye & ENT Hosp, Shanghai 200031, Peoples R China
关键词
Break-up time; cataract; dry eye; Keratograph; 4; CORNEAL SENSITIVITY; PRECORNEAL; THICKNESS; STABILITY; FLUORESCEIN; DYNAMICS; PRELENS; TESTS;
D O I
10.1177/0300060513504701
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To investigate tear-film break-up time and spatial distribution via noninvasive Keratograph 4 in patients with cataracts and dry eye syndrome (DES). Methods Noninvasive first break-up time (NIKf-BUT) and average break-up time (NIKav-BUT) were evaluated via Keratograph 4 in patients with age-related cataracts and DES. The location and size of tear break regions were recorded and the distribution of first break-up areas was summarized. Patients also underwent conventional break-up time assessments (TBUT test and Schirmer's test). Results A total of 43 left and 43 right eyes were examined. There was no significant difference between TBUT and NIKav-BUT. NIKf-BUT was significantly shorter than TBUT. Both NIKf-BUT and NIKav-BUT correlated positively with TBUT. In both the left and right eye, the most common first break-up areas were the peripheral domain of the inferior precorneal surface and the central domain of the superior portion. Conclusions The Keratograph 4 appears to provide an effective noninvasive method for assessing tear film, enabling effective preoperative evaluation of tear film break-up regularity, informing the location of the incision and reducing the probability of postoperative DES.
引用
收藏
页码:494 / 502
页数:9
相关论文
共 43 条
[1]  
Abelson MB, 2002, ADV EXP MED BIOL, V506, P1121
[2]  
BENEDETTO DA, 1984, ARCH OPHTHALMOL-CHIC, V102, P410
[3]   SURFACE-TENSION GRADIENT MECHANISM FOR DRIVING PRECORNEAL TEAR FILM AFTER A BLINK [J].
BERGER, RE ;
CORRSIN, S .
JOURNAL OF BIOMECHANICS, 1974, 7 (03) :225-&
[4]   Clinical evaluation of the Oculus Keratograph [J].
Best, N. ;
Drury, L. ;
Wolffsohn, J. S. .
CONTACT LENS & ANTERIOR EYE, 2012, 35 (04) :171-174
[5]  
Bron AJ, 2007, OCUL SURF, V5, P108
[6]   RELIABILITY OF THE TEAR BREAK-UP TIME TECHNIQUE OF ASSESSING TEAR STABILITY AND THE LOCATIONS OF THE TEAR BREAK-UP IN HONG-KONG CHINESE [J].
CHO, P ;
BROWN, B ;
CHAN, I ;
CONWAY, R ;
YAP, M .
OPTOMETRY AND VISION SCIENCE, 1992, 69 (11) :879-885
[7]   Effect of fluorescein on the tear stability of Hong Kong Chinese [J].
Cho, P ;
Brown, B ;
Lau, C .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :1-7
[8]   THE RELATION BETWEEN INVASIVE AND NONINVASIVE TEAR BREAK-UP TIME [J].
CHO, P ;
DOUTHWAITE, W .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (01) :17-22
[9]  
Cho Yang Kyeung, 2009, Korean J Ophthalmol, V23, P65, DOI 10.3341/kjo.2009.23.2.65
[10]   Strip meniscometry: A new and simple method of tear meniscus evaluation [J].
Dogru, Murat ;
Ishida, Katsushi ;
Matsumoto, Yukihiro ;
Goto, Eiki ;
Ishioka, Misaki ;
Kojima, Takashi ;
Goto, Tateki ;
Saeki, Megumi ;
Tsubota, Kazuo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (05) :1895-1901