Noninvasive Keratograph assessment of tear film break-up time and location in patients with age-related cataracts and dry eye syndrome

被引:71
|
作者
Jiang, Yongxiang [1 ]
Ye, Hongfei [1 ]
Xu, Jianjiang [1 ]
Lu, Yi [1 ]
机构
[1] Fudan Univ, Dept Ophthalmol, Eye & ENT Hosp, Shanghai 200031, Peoples R China
关键词
Break-up time; cataract; dry eye; Keratograph; 4; CORNEAL SENSITIVITY; PRECORNEAL; THICKNESS; STABILITY; FLUORESCEIN; DYNAMICS; PRELENS; TESTS;
D O I
10.1177/0300060513504701
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To investigate tear-film break-up time and spatial distribution via noninvasive Keratograph 4 in patients with cataracts and dry eye syndrome (DES). Methods Noninvasive first break-up time (NIKf-BUT) and average break-up time (NIKav-BUT) were evaluated via Keratograph 4 in patients with age-related cataracts and DES. The location and size of tear break regions were recorded and the distribution of first break-up areas was summarized. Patients also underwent conventional break-up time assessments (TBUT test and Schirmer's test). Results A total of 43 left and 43 right eyes were examined. There was no significant difference between TBUT and NIKav-BUT. NIKf-BUT was significantly shorter than TBUT. Both NIKf-BUT and NIKav-BUT correlated positively with TBUT. In both the left and right eye, the most common first break-up areas were the peripheral domain of the inferior precorneal surface and the central domain of the superior portion. Conclusions The Keratograph 4 appears to provide an effective noninvasive method for assessing tear film, enabling effective preoperative evaluation of tear film break-up regularity, informing the location of the incision and reducing the probability of postoperative DES.
引用
收藏
页码:494 / 502
页数:9
相关论文
共 23 条
  • [1] Corneal hyperalgesia in patients with short tear film break-up time dry eye
    Tagawa, Yoshiaki
    Noda, Kousuke
    Ohguchi, Takeshi
    Tagawa, Yoshitsugu
    Ishida, Susumu
    Kitaichi, Nobuyoshi
    OCULAR SURFACE, 2019, 17 (01): : 55 - 59
  • [2] Location and pattern of non-invasive keratographic tear film break-up according to dry eye disease subtypes
    Kim, Jieun
    Kim, Jung Yong
    Seo, Kyoung Yul
    Kim, Tae-im
    Chin, Hee Seung
    Jung, Ji Won
    ACTA OPHTHALMOLOGICA, 2019, 97 (08) : E1089 - E1097
  • [3] NONINVASIVE TEAR FILM BREAK-UP TIME ASSESSMENT USING HANDHELD LIPID LAYER EXAMINATION INSTRUMENT
    Pauk, Sania Vidas
    Petricek, Igor
    Jukic, Tomislav
    Popovic-Suic, Smiljka
    Tomic, Martina
    Kalauz, Miro
    Jandrokovic, Sonja
    Masnec, Sanja
    ACTA CLINICA CROATICA, 2019, 58 (01) : 63 - 71
  • [4] Assessment of tear film optical quality in a young short tear break-up time dry eye Case-control study
    Xi, Lei
    Qin, Jiayin
    Bao, Yongzhen
    MEDICINE, 2019, 98 (40)
  • [5] Reliability of a New Non-invasive Tear Film Break-up Time Measurement Using a Keratograph
    Jeong, Seongyong
    Lee, Sang Bumm
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (09): : 1354 - 1360
  • [6] Tear Film Break-Up Time and Dry Eye Disease Severity in a Large Norwegian Cohort
    Yazdani, Mazyar
    Fiskadal, Jorgen
    Chen, Xiangjun
    Utheim, Oygunn A.
    Raeder, Sten
    Vitelli, Valeria
    Utheim, Tor P.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) : 1 - 16
  • [7] Relationship of Corneal Pain Sensitivity With Dry Eye Symptoms in Dry Eye With Short Tear Break-Up Time
    Kaido, Minako
    Kawashima, Motoko
    Ishida, Reiko
    Tsubota, Kazuo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (03) : 914 - 919
  • [8] Tear film assessment before and after phacoemulsification in patients with age-related cataracts
    Shaaban, Yasmine Maher
    Aziz, Bassem Fayez
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [9] Analysis of the first tear film break-up point in Sjogren's syndrome and non-Sjogren's syndrome dry eye patients
    Zhao, Songjiao
    Le, Qihua
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [10] Capsaicin-induced pain sensitivity in short tear break-up time dry eye
    Kaido, Minako
    Inoue, Sachiko
    Kawashima, Motoko
    Ishida, Reiko
    Nakamura, Shigeru
    Tsubota, Kazuo
    OCULAR SURFACE, 2020, 18 (04): : 620 - 626