Influence of object location in cone beam computed tomography (NewTom 5G and 3D Accuitomo 170) on gray value measurements at an implant site

被引:16
作者
Parsa, Azin [1 ]
Ibrahim, Norliza [1 ,2 ]
Hassan, Bassam [1 ]
van der Stelt, Paul [1 ]
Wismeijer, Daniel [3 ]
机构
[1] Acad Ctr Dent Amsterdam ACTA, Oral & Maxillofacial Radiol Sect, Dept Gen & Specialized Dent, NL-1081 LA Amsterdam, Netherlands
[2] Univ Malaya, Fac Dent, Dept Gen Dent Practice & Oral & Maxillofacial Ima, Kuala Lumpur, Malaysia
[3] Acad Ctr Dent Amsterdam ACTA, Dept Oral Implantol & Prosthodont, NL-1081 LA Amsterdam, Netherlands
关键词
Cone-beam computed tomography; Bone density; Dental implants; Patient positioning; MAXILLOFACIAL REGION; VOXEL VALUES; GREY LEVELS; RELIABILITY; CONVERSION; CBCT;
D O I
10.1007/s11282-013-0157-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine the gray value variation at an implant site with different object location within the selected field of view (FOV) in two cone beam computed tomography (CBCT) scanners. A 1-cm-thick section from the edentulous region of a dry human mandible was scanned by two CBCT scanners: 3D Accuitomo 170 (J. Morita, Kyoto, Japan) and NewTom 5G (QR Verona, Verona, Italy). Five FOVs were used with each CBCT scanner. Within each FOV, the specimen was located at different positions. The scans were converted to DICOM format. Data analysis was performed using 3Diagnosys (ver. 3.1, 3DIEMME, Cantu, Italy) and Geomagic software (Studio 2012, Morrisville, NC). On one of the scans, a probe designating the site for pre-operative implant placement was selected. The inserted virtual implant was transformed on the same region on each CBCT scan by a three-dimensional registration algorithm. The mean voxel gray value of the region around the probe was derived separately from all CBCT scans. The influence of object location within each FOV on variability of voxel gray values was assessed. In both CBCT systems, object location had a significant influence on gray value measurements (F (4,16) = 3.71, p = 0.0255 for Accuitomo and F (4,16) = 9.31, p = 0.0000 for NewTom). Gray level values from CBCT images are influenced by object location within the FOV.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 33 条
[31]   Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners [J].
Suomalainen, A. ;
Kiljunen, T. ;
Kaser, Y. ;
Peltola, J. ;
Kortesniemi, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (06) :367-378
[32]   Radiographic examination of the temporomandibular joint using cone beam computed tomography [J].
Tsiklakis, K ;
Syriopoulos, K ;
Stamatakis, H .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (03) :196-201
[33]   CONE-BEAM IMAGING IN DENTISTRY [J].
White, Stuart C. .
HEALTH PHYSICS, 2008, 95 (05) :628-637