Three-Dimensional Dynamic Time-Resolved Contrast-Enhanced MRA Using Parallel Imaging and a Variable Rate k-Space Sampling Strategy in Intracranial Arteriovenous Malformations

被引:39
作者
Petkova, Mina [2 ]
Gauvrit, Jean-Yves [1 ]
Trystram, Denis [2 ]
Nataf, Francois [2 ]
Godon-Hardy, Sylvie [2 ]
Munier, Thierry [3 ]
Oppenheim, Catherine [2 ]
Meder, Jean-Francois [2 ]
机构
[1] Pontchaillou Hosp, Dept Neuroimaging, Rennes, France
[2] Univ Paris 05, Dept Neuroradiol & Neurosurg, Paris, France
[3] Gen Elect Healthcare Technol, Buc, France
关键词
3D dynamic time-resolved contrast-enhanced MRA; TRICKS; intracranial arteriovenous malformation; digital subtraction angiography; DIGITAL-SUBTRACTION-ANGIOGRAPHY; NEUROLOGIC COMPLICATIONS; CEREBRAL-ANGIOGRAPHY; FISTULAS;
D O I
10.1002/jmri.21483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of three-dimensional (3D) dynamic time-resolved contrast-enhanced MRA (TR-CE-MRA) using a combination of a parallel imaging technique (ASSET: array spatial sensitivity encoding technique) and a time-resolved method (TRICKS: time-resolved imaging of contrast kinetics) and to compare it with 3D dynamic TR-CE-MRA using ASSET alone in the assessment of intracranial arteriovenous malformations (AVMs). Materials and Methods: Twenty consecutive patients with angiographically confirmed AVMs were investigated using both 3D dynamic TR-CE-MRA techniques. Examinations were compared with respect to image quality, spatial resolution, number and type of feeders and drainers, nidus size, presence of early venous filling and temporal resolution. Digital subtraction angiography was used as standard of reference. Results: The higher temporal and spatial resolution of 3D dynamic TR-CE-MRA TRICKS ASSET allowed a better assessment of intracranial vascular malformations, namely better depiction of feeders, drainers and better detection of early venous drainage. There was no significant difference between them in terms of nidus size. Conclusion: 3D dynamic TR-CE-MRA combining parallel imaging and a time-resolved method with subsecond and submillimeter resolution could become the first-line investigation technique in both diagnosis and follow-up of Intracranial AVMs.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 24 条
[1]   MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas [J].
Aoki, S ;
Yoshikawa, T ;
Hori, M ;
Nanbu, A ;
Kumagai, H ;
Nishiyama, Y ;
Nukui, H ;
Araki, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :451-453
[2]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[3]   Neurovascular MRI with dynamic contrast-enhanced subtraction angiography [J].
Coley, SC ;
Wild, JM ;
Wilkinson, ID ;
Griffiths, PD .
NEURORADIOLOGY, 2003, 45 (12) :843-850
[4]  
Coley SC, 2002, AM J NEURORADIOL, V23, P404
[5]   COMPLICATIONS OF CEREBRAL-ANGIOGRAPHY - PROSPECTIVE ASSESSMENT OF RISK [J].
EARNEST, F ;
FORBES, G ;
SANDOK, BA ;
PIEPGRAS, DG ;
FAUST, RJ ;
ILSTRUP, DM ;
ARNDT, LJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (02) :247-253
[6]  
Evans AL, 2005, ACTA RADIOL, V46, P625, DOI 10.1080/02841850510021779
[7]  
Gauvrit JY, 2005, AM J NEURORADIOL, V26, P1525
[8]  
Griffiths PD, 2000, AM J NEURORADIOL, V21, P1892
[9]  
HEISERMAN JE, 1994, AM J NEURORADIOL, V15, P1401
[10]   Time-resolved projection MRA: clinical application in intracranial vascular malformations [J].
Klisch, J ;
Strecker, R ;
Henning, J ;
Schumacher, M .
NEURORADIOLOGY, 2000, 42 (02) :104-107