Optimal end-tidal concentration of sevoflurane to test an ankle clonus in children

被引:3
作者
Chang, Chul Ho
Choi, Seung Ho
Shim, Yon Hee
Lee, Ki-Young
Lee, Hwan-Mo
Shin, Yang-Sik
机构
[1] Yonsei Univ, Dept Anesthesiol & Pain Med, Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Dept Anesthesia, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Pain Res Inst, Coll Med, Seoul 120752, South Korea
[4] Yonsei Univ, Dept Orthoped Surg, Coll Med, Seoul 120752, South Korea
关键词
spinal cord; ankle clonus; sevoflurane; end-tidal concentration; children;
D O I
10.1097/01.brs.0000238680.39230.67
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective randomized study on the end-tidal concentrations of sevoflurane at which ankle clonus existed. Summary of Background Data. The ankle clonus reflex is a transient neurologic abnormality, which normally occurs in patients during emergence from general anesthesia. Objective. To determine the optimal end-tidal concentration of sevoflurane to test an ankle clonus in children during emergence from general anesthesia. Methods. We studied 30 children (aged 5 -15 years). General anesthesia was induced with thiopental sodium. Anesthesia was maintained with sevoflurane, oxygen, and air. At completion of surgery, 3% volume of the end-tidal sevoflurane concentration was maintained for at least 10 minutes. Ankle clonus was checked at 1.0% to 0.1% volume of the end-tidal sevoflurane concentration with an interval of 0.05% volume. Results. Of children, 80% had bilateral ankle clonus, which was found most frequently when patients responded poorly to verbal commands. The median of the end-tidal sevoflurane concentration for a reactive ankle clonus was 0.45% volume (interquartile range 0.5% to 0.4% volume). Conclusions. The ankle clonus should be tested at 0.45% volume of end-tidal sevoflurane concentration in children undergoing scoliosis surgery during emergence from the general anesthesia.
引用
收藏
页码:E813 / E816
页数:4
相关论文
共 43 条
  • [21] Effects of inhalational anaesthesia with low tidal volume ventilation on end-tidal sevoflurane and carbon dioxide concentrations: prospective randomized study
    de la Matta-Martin, M.
    Lopez-Herrera, D.
    Luis-Navarro, J. C.
    Lopez-Romero, J. L.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2014, 61 (02): : 78 - 86
  • [22] Effects of Intravenous Fentanyl Administration on End-Tidal Sevoflurane Concentrations in Thoroughbred Racehorses undergoing Orthopedic Surgery
    Ohta, Minoru
    Wakuno, Ai
    Okada, Jun
    Kodaira, Kazumichi
    Nagata, Shun-ichi
    Ito, Motoki
    Oku, Kazuomi
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2010, 72 (09) : 1107 - 1111
  • [23] The Effect of Chronic Opioid Use on End-Tidal Concentration of Sevoflurane Necessary to Maintain a Bispectral Index Below 50: A Prospective, Single-Blind Study
    Oh, Tak Kyu
    Eom, Woosik
    Yim, Jiyeon
    Kim, Namwoo
    Kwon, Kyungho
    Kim, Seong-Eun
    Kim, Dae Hyun
    ANESTHESIA AND ANALGESIA, 2017, 125 (01) : 156 - 161
  • [24] Automated control of end-tidal inhalation anaesthetic concentration using the GE Aisys Carestation™
    Singaravelu, S.
    Barclay, P.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (04) : 561 - 566
  • [25] The end-tidal desflurane concentration for smooth removal of the laryngeal mask airway in anaesthetised adults
    Sahiner, Yeliz
    Ozkan, Derya
    Akkaya, Taylan
    Goral, Nilgun
    Alptekin, Alp
    Gumus, Haluk
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (03) : 187 - 189
  • [26] Discrepant End-Tidal Concentrations of Sevoflurane at the Same A-Line Autoregressive Index Level during Induction of General Anesthesia: An Observational Study
    Hsu, Che-Hao
    Ho, Shung-Tai
    Lu, Chih-Cherng
    Wang, Ju-O
    Yeh, Te-Chun
    Lin, Tso-Chou
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
  • [27] Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired-end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
    Dias, Raylene
    Dave, Nandini
    Agrawal, Barkha
    Baghele, Aarti
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (04) : 277 - 283
  • [28] Optimum end-tidal concentration of sevoflurane to facilitate supraglottic airway device insertion with propofol at induction allowing spontaneous respiration in obese patients A prospective observational study
    Wang, Hai-Xia
    Miao, Hui-Hui
    Gao, Xue
    Wei, Wei
    Ding, Guan-Nan
    Zhang, Ye
    Tian, Ming
    MEDICINE, 2017, 96 (47)
  • [29] Effect of End-Tidal Carbon Dioxide on Cerebral Dynamics in Infants With Ventricular Septal Defect: A Comparison Between Sevoflurane and Intravenous Anesthetics
    Zhang, Weizhi
    Xie, Siyuan
    Han, Ding
    Ou-Yang, Chuan
    Lu, Jiakai
    Huang, Jiapeng
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (06) : 1558 - 1564
  • [30] Efficiency of CONTRAfluran™ in reducing sevoflurane pollution from maintenance anaesthesia in minimal flow end-tidal control mode for laparoscopic surgery
    Mulier, Harold
    Struys, Michel M. R. F.
    Vereecke, Hugo
    Rex, Steffen
    Teunkens, An
    Kalmar, Alain F.
    ANAESTHESIA, 2024, 79 (08) : 849 - 855