Morphologic and hemodynamic changes after stent placement for experimental carotid aneurysm

被引:2
作者
Tenjin, H [1 ]
Ohshita, Y
Daimon, R
机构
[1] Kyoto Prefectural Yosanoumi Hosp, Dept Neurosurg, Kyoto 6292261, Japan
[2] Kyoto Prefectural Yosanoumi Hosp, Dept Radiol, Kyoto 6292261, Japan
来源
INTERVENTIONAL NEURORADIOLOGY | 2002年 / 8卷 / 02期
关键词
cerebral aneurysm; stent;
D O I
10.1177/159101990200800206
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Stent assisted coil embolization is useful in treating broad neck aneurysms, and there are many kinds of stents that can be applied in the cerebral artery, however their characteristics are not well known. We investigated and compared morphologic and hemodynamic changes before and after stent placement when several different kinds of stents were applied to experimental aneurysms. Experimental aneurysms in eight pig carotid arteries were used. Stents were placed covering the aneurysm orifice. Five Cordis stents (coil stent), two GFXs (multilink stent), and one Multilink (tube stent) were used in this study. After coil placement, the arteries were perfused with 70% ethanol, the specimens were embedded in polyester plastic resin and thin slices were stained with hematoxylin-eosin. Blood flow in the aneurysm was measured using digital subtraction angiography. The parent artery was stretched in multilink stent (GFX) cases, and was most markedly stretched by use of the tube stent (Multilink). Stent placement with any type of stent decreased intra-aneurysmal blood flow.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 12 条
  • [1] Modeling of flow in a straight stented and nonstented side wall aneurysm model
    Aenis, M
    Stancampiano, AP
    Wakhloo, AK
    Lieber, BB
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02): : 206 - 212
  • [2] ASAKURA F, 1996, J KYOTO PREF U MED, V105, P963
  • [3] Combined endovascular stenting and endosaccular coiling for the treatment of a wide-necked intracranial vertebral aneurysm - Technical case report
    Bracard, S
    Anxionnat, R
    Da Costa, E
    Lebedinsky, A
    Scomazzoni, F
    Picard, L
    [J]. INTERVENTIONAL NEURORADIOLOGY, 1999, 5 (03) : 245 - 249
  • [4] ELECTROTHROMBOSIS OF SACCULAR ANEURYSMS VIA ENDOVASCULAR APPROACH .2. PRELIMINARY CLINICAL-EXPERIENCE
    GUGLIELMI, G
    VINUELA, F
    DION, J
    DUCKWILER, G
    [J]. JOURNAL OF NEUROSURGERY, 1991, 75 (01) : 8 - 14
  • [5] Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery - Case report and review of the literature
    Higashida, RT
    Smith, W
    Gress, D
    Urwin, R
    Dowd, CF
    Balousek, PA
    Halbach, VV
    [J]. JOURNAL OF NEUROSURGERY, 1997, 87 (06) : 944 - 949
  • [6] Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity
    Lieber, BB
    Stancampiano, AP
    Wakhloo, AK
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (03) : 460 - 469
  • [7] MASSOUD TF, 1995, AM J NEURORADIOL, V16, P1953
  • [8] Stenting and secondary coiling of intracranial internal carotid artery aneurysm: Technical case report
    Mericle, RA
    Lanzino, G
    Wakhloo, AK
    Guterman, LR
    Hopkins, LN
    [J]. NEUROSURGERY, 1998, 43 (05) : 1229 - 1233
  • [9] Combined endovascular stent implantation and endosaccular coil placement for the treatment of a wide-necked vertebral artery aneurysm: Technical case report
    Sekhon, LHS
    Morgan, MK
    Sorby, W
    Grinnell, V
    [J]. NEUROSURGERY, 1998, 43 (02) : 380 - 383
  • [10] Tenjin H, 1998, AM J NEURORADIOL, V19, P1303