Silver-selective sensor using an electrode-separated piezoelectric quartz crystal modified with a chitosan derivative

被引:15
作者
Bao, SH [1 ]
Nomura, T [1 ]
机构
[1] Shinshu Univ, Fac Sci, Dept Chem, Matsumoto, Nagano 3908621, Japan
关键词
D O I
10.2116/analsci.18.881
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver(I) adsorbed selectively onto a quartz plate modified with N-(2-pyridylmethyl)chitosan in an ammonium chloride buffer solution containing EDTA, and the frequency of the quartz plate increased. It was supposed that the increasing frequency was caused by the desorption of adsorbed water on the chitosan derivative, Which was induced from the reaction of silver(I) with the chitosan derivative. The concentration of the buffer, pH, temperature, conductivity and eluent affected the frequency shift resulting from the adsorption of silver(I). The frequency decreased at a conductivity lower than 2.2 mS/cm, and increased with increasing conductivity above this value. The frequency shifts caused by the adsorption of silver(I) were proportional to the concentration over the range 10-80 nM of silver(l), and the correlation coefficient was 0.9969. The detection limit and the relative standard deviation at 50 nM for five times were 6 nM and 3.4%, respectively. The proposed method was simple while showing higher sensitivity and selectivity.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 24 条
[1]   SELECTIVE ABSORPTION OF PALLADIUM(II), PLATINUM(IV), AND MERCURY(II) ON A NEW CHITOSAN DERIVATIVE POSSESSING PYRIDYL GROUP [J].
BABA, Y ;
HIRAKAWA, H .
CHEMISTRY LETTERS, 1992, (10) :1905-1908
[2]   Highly selective adsorption resins .1. Preparation of chitosan derivatives containing 2-pyridylmethyl, 2-thienylmethyl, and 3-(methylthio)propyl groups and their selective adsorption of precious metals [J].
Baba, Y ;
Kawano, Y ;
Hirakawa, H .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1996, 69 (05) :1255-1260
[3]   Determination of copper (II) in solution using a twinned piezoelectric quartz crystal coated with chitosan [J].
Bao, SH ;
Nomura, T .
BUNSEKI KAGAKU, 2002, 51 (04) :255-260
[4]   DEVELOPMENT OF A FLOW-INJECTION ANALYSIS SYSTEM UTILIZING PIEZOELECTRIC-CRYSTALS FOR THE DETERMINATION OF CYANIDE EMPLOYING SMALL SAMPLE SIZES [J].
BUNDE, RL ;
ROSENTRETER, JJ .
MICROCHEMICAL JOURNAL, 1993, 47 (1-2) :148-156
[5]   ADSORPTION OF METAL-IONS ON CHITOSAN AND CROSS-LINKED COPPER(II)-COMPLEXED CHITOSAN [J].
INOUE, K ;
BABA, Y ;
YOSHIZUKA, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1993, 66 (10) :2915-2921
[6]   A PIEZOELECTRIC TRANSDUCER FOR DETERMINATION OF METALS AT MICROMOLAR LEVEL [J].
JONES, JL ;
MIEURE, JP .
ANALYTICAL CHEMISTRY, 1969, 41 (03) :484-&
[7]   PIEZOELECTRIC-CRYSTALS AS DETECTORS IN LIQUID-CHROMATOGRAPHY [J].
KONASH, PL ;
BASTIAANS, GJ .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1929-1931
[8]   A PIEZOELECTRIC QUARTZ-CRYSTAL BIOSENSOR AS A DIRECT AFFINITY SENSOR [J].
MINUNNI, M ;
SKLADAL, P ;
MASCINI, M .
ANALYTICAL LETTERS, 1994, 27 (08) :1475-1487
[9]   Adsorptive determination of copper(II) in solution as its N,N-diethyldithiocarbamate on an electrode-separated piezoelectric quartz crystal [J].
Nomura, T ;
Kumagai, M ;
Sato, A .
ANALYTICA CHIMICA ACTA, 1997, 343 (03) :209-213
[10]   ELECTROLYTIC DETERMINATION OF NANOMOLAR CONCENTRATIONS OF SILVER IN SOLUTION WITH A PIEZOELECTRIC QUARTZ CRYSTAL [J].
NOMURA, T ;
IIJIMA, M .
ANALYTICA CHIMICA ACTA, 1981, 131 (NOV) :97-102