Radioactive seed localization of nonpalpable breast lesions is better than wire localization

被引:123
作者
Gray, RJ [1 ]
Pockaj, BA
Karstaedt, PJ
Roarke, MC
机构
[1] Mayo Clin, Dept Surg, Sect Surg Oncol, Scottsdale, AZ 85259 USA
[2] Mayo Clin, Dept Diagnost Radiol, Sect Breast Imaging, Scottsdale, AZ USA
[3] Mayo Clin, Nucl Med Sect, Scottsdale, AZ USA
关键词
breast cancer; nonpalpable; radioactive seed localization; wire localization;
D O I
10.1016/j.amjsurg.2004.06.023
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The current study sought to validate radioactive seed localization (RSL) as an alternative to wire localization (WL) to facilitate the operative excision of nonpalpable breast lesions. Methods: One hundred consecutive patients underwent preoperative WL and the next 100 RSL. Margins were considered negative if greater than or equal to2 rum from in situ and invasive disease. Results: RSL resulted in 100% retrieval of the seeds and lesions. Sixty-eight percent of patients underwent RSL at least 1 day before surgery. RSL resulted in a 35% relative improvement in the rate of negative margins in the first specimen (P = 0.01) and a 62% relative improvement in the rate of reoperation for positive margins (P = 0.01). The sentinel lymph node (SLN) identification rate was 100% in both groups. Conclusions: RSL is effective and safe, and this procedure significantly improved the rate of negative margins in the first specimen and the rate of reoperation for positive margins compared to WL. We highly favor RSL over WL. (C) 2004 Excerpta Medica, Inc. All rights reserved.
引用
收藏
页码:377 / 380
页数:4
相关论文
共 20 条
[1]   Breast biopsy with wire localization: factors influencing complete excision of nonpalpable carcinoma [J].
Besic, N ;
Zgajnar, J ;
Hocevar, M ;
Rener, M ;
Frkovic-Grazio, S ;
Snoj, N ;
Lindtner, J .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2684-2689
[2]   TRANSGRESSION OF LOCALIZING WIRE INTO THE PLEURAL CAVITY PRIOR TO MAMMOGRAPHY [J].
BRISTOL, JB ;
JONES, PA .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (638) :139-140
[3]   MIGRATION OF BREAST BIOPSY LOCALIZATION WIRE [J].
DAVIS, PS ;
WECHSLER, RJ ;
FEIG, SA ;
MARCH, DE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (04) :787-788
[4]   Localization of impalpable breast lesions - A surgical approach [J].
dellaRovere, GQ ;
Benson, JR ;
Morgan, M ;
Warren, R ;
Patel, A .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1996, 22 (05) :478-482
[5]   Prospective assessment of a new graduated hookwire for the localization of impalpable breast lesions [J].
Flanagan, JJ ;
Conry, BG ;
Rubin, G ;
Mills, P ;
Bentley, PG .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (820) :341-343
[6]  
Fornage B D, 2000, JBR-BTR, V83, P75
[7]   Use of technetium-99m-labeled colloid albumin for preoperative and intraoperative localization of nonpalpable breast lesions [J].
Gennari, R ;
Galimberti, V ;
De Cicco, C ;
Zurrida, S ;
Zerwes, F ;
Pigatto, F ;
Luini, A ;
Paganelli, G ;
Veronesi, U .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2000, 190 (06) :692-698
[8]  
Gray RJ, 2001, ANN SURG ONCOL, V8, P711
[9]   Intraoperative ultrasound localization to guide surgical excision of nonpalpable breast carcinoma [J].
Harlow, SP ;
Krag, DN ;
Ames, SE ;
Weaver, DL .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 189 (03) :241-246
[10]   TRANSECTION OF THE LOCALIZATION HOOKED WIRE DURING BREAST BIOPSY [J].
HOMER, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (05) :929-930