Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine

被引:87
作者
Reitman, CA [1 ]
Nguyen, L [1 ]
Fogel, GR [1 ]
机构
[1] Baylor Coll Med, Houston, TX 77030 USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2004年 / 17卷 / 04期
关键词
cervical spine; bone mineral density; screw pullout strength; insertional torque; biomechanics;
D O I
10.1097/01.bsd.0000090575.08296.9d
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Understanding of implant failure mechanisms is important in the successful utilization of anterior cervical plates. Many variables influence screw purchase, including the quality of the bone. The purpose of this study was to assess the relationship of screw pull-out and screw insertional torque across a wide range of bone mineral densities (BMDs). Methods: A total of 54 cervical vertebrae in 12 cervical spines were evaluated for BMD using dual-energy x-ray absorptiometry scanning. Actual and perceived peak torques of 3.5-mm anterior cervical screws were determined at each level followed by screw pullout strength testing. Results: A high correlation was observed between screw pullout strength and BMD. However, there was a low correlation of peak insertional torque to pullout strength. Conclusion: These findings suggest the quality of the bone is more instrumental in the success or failure of anterior cervical screws than is the insertional torque with which the screws are placed.
引用
收藏
页码:306 / 311
页数:6
相关论文
共 16 条
  • [1] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [2] INFLUENCE OF BONE-MINERAL DENSITY ON THE FIXATION OF THORACOLUMBAR IMPLANTS - A COMPARATIVE-STUDY OF TRANSPEDICULAR SCREWS, LAMINAR HOOKS, AND SPINOUS PROCESS WIRES
    COE, JD
    WARDEN, KE
    HERZIG, MA
    MCAFEE, PC
    [J]. SPINE, 1990, 15 (09) : 902 - 907
  • [3] FOGEL GR, IN PRESS SPINE J
  • [4] Hadjipavlou AG, 1997, J SPINAL DISORD, V10, P12
  • [5] Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws
    Hitchon, PW
    Brenton, MD
    Coppes, JK
    From, AM
    Torner, JC
    [J]. SPINE, 2003, 28 (01) : 9 - 13
  • [6] LIM TH, 1995, J SPINAL DISORD, V8, P121
  • [7] Lovick DS, 1997, J SPINAL DISORD, V10, P431
  • [8] ODUYAMA K, 1993, SPINE, V18, P2240
  • [9] Ryken T C, 1995, J Neurosurg, V83, P325
  • [10] Biomechanical evaluation of anterior spinal instrumentation systems for scoliosis -: In vitro fatigue simulation
    Shimamoto, N
    Kotani, Y
    Shono, Y
    Kadoya, K
    Abumi, K
    Kaneda, K
    Minami, A
    [J]. SPINE, 2001, 26 (24) : 2701 - 2708