The method of testing of XLPE cable insulation resistance to partial discharges and electrical treeing

被引:0
|
作者
Jevtic, M [1 ]
Andreev, AM [1 ]
机构
[1] ST PETERSBURG TECH UNIV,ELECTROMECH FAC,ST PETERSBURG,RUSSIA
关键词
electrical treeing; partial discharges; XLPE cable insulation;
D O I
10.1007/BF02745202
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper gives a method of model XLPE medium voltage cable insulation testing for partial discharges and electrical treeing with a point to plane test geometry. Based on this method, a comparative estimate of insulation resistance to treeing and partial discharges have been made. XLPE crosslinked by different methods (steam medium and hot nitrogen medium) and with varying contents of inorganic filler kaolin were tested. The characteristics of partial discharges were measured by means of a pulse height analyser characterized with a microscope. The data have been analysed statistically.
引用
收藏
页码:823 / 829
页数:7
相关论文
共 50 条
  • [21] Electrical Treeing Test of DC Cable XLPE Insulation under DC Voltage and High Temperature
    Liu, Ying
    Xiao, Yang
    Su, Yu
    Chen, Xin
    Zhang, Chong
    Li, Wenpeng
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 752 - 755
  • [22] Study on the partial discharge characteristics of the XLPE insulation samples during electrical treeing ageing
    Cheng, YH
    Chen, XL
    Rong, MZ
    Yue, B
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 211 - 214
  • [23] WATER TREEING AND DIELECTRIC LOSS OF WTR-XLPE CABLE INSULATION
    FAREMO, H
    ILDSTAD, E
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1993, 140 (05): : 393 - 396
  • [24] Partial Discharge Characteristics of Electrical Treeing in XLPE insulation utilizing Multi Level PWM Waveforms
    Hammarstrom, Thomas John Ake
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 4699 - 4704
  • [25] Electrical Treeing Characteristics in XLPE Power Cable Insulation in Frequency Range between 20 and 500 Hz
    Chen, G.
    Tham, C. H.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) : 179 - 188
  • [26] Understanding Treeing Phenomena in XLPE Cable Insulation Under Composite Voltages
    Priya, K. G. Shanmuga
    Prabu, R. Raja
    Kumar, C. L. G. Pavan
    Sarathi, R.
    2013 8TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (ICIIS), 2013, : 100 - +
  • [27] Investigation on water treeing behaviors of thermally aged XLPE cable insulation
    Kim, Chonung
    Jin, Zhijian
    Huang, Xingyi
    Jiang, Pingkai
    Ke, Qingquan
    POLYMER DEGRADATION AND STABILITY, 2007, 92 (04) : 537 - 544
  • [28] Partial discharge characteristics of electrical treeing in XLPE insulation exposed to voltages of different rise times
    Hammarström T.
    Bengtsson T.
    Gubanski S.M.
    IEEJ Transactions on Fundamentals and Materials, 2019, 139 (02) : 85 - 91
  • [29] Partial Discharge Characteristics of Electrical Treeing in XLPE Insulation Exposed to Voltages of Different Rise Times
    Hammarstrom, T. J. A.
    Bengtsson, T.
    Gubanski, S. M.
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 407 - 410
  • [30] Partial discharge phenomena due to electrical treeing in XLPE
    Yang, J. J.
    Zhang, D. M.
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1709 - +