Cone beam computed tomography guided treatment delivery and planning verification for magnetic resonance imaging only radiotherapy of the brain

被引:32
作者
Edmund, Jens M. [1 ]
Andreasen, Daniel [1 ,2 ]
Mahmood, Faisal [1 ]
Van Leemput, Koen [2 ,3 ]
机构
[1] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Oncol, Radiotherapy Res Unit, Herlev, Denmark
[2] Tech Univ Denmark, DTU Compute, DK-2800 Lyngby, Denmark
[3] Harvard Univ, Sch Med, Dept Radiol, Massachusetts Gen Hosp, Boston, MA 02115 USA
关键词
MRI-ONLY RADIOTHERAPY; PSEUDO-CT; HEAD;
D O I
10.3109/0284186X.2015.1062546
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Radiotherapy based on MRI only (MRI-only RT) shows a promising potential for the brain. Much research focuses on creating a pseudo computed tomography (pCT) from MRI for treatment planning while little attention is often paid to the treatment delivery. Here, we investigate if cone beam CT (CBCT) can be used for MRI-only image-guided radiotherapy (IGRT) and for verifying the correctness of the corresponding pCT.Material and methods. Six patients receiving palliative cranial RT were included in the study. Each patient had three-dimensional (3D) T1W MRI, a CBCT and a CT for reference. Further, a pCT was generated using a patch-based approach. MRI, pCT and CT were placed in the same frame of reference, matched to CBCT and the differences noted. Paired pCT-CT and pCT-CBCT data were created in bins of 10 HU and the absolute difference calculated. The data were converted to relative electron densities (RED) using the CT or a CBCT calibration curve. The latter was either based on a CBCT phantom (phan) or a paired CT-CBCT population (pop) of the five other patients.Results. Non-significant (NS) differences in the pooled CT-CBCT, MRI-CBCT and pCT-CBCT transformations were noted. The largest deviations from the CT-CBCT reference were < 1 mm and 1 degrees. The average median absolute error (MeAE) in HU was 184 34 and 299 +/- 34 on average for pCT-CT and pCT-CBCT, respectively, and was significantly different (p < 0.01) in each patient. The average MeAE in RED was 0.108 +/- 0.025, 0.104 +/- 0.011 and 0.099 +/- 0.017 for pCT-CT, pCT-CBCT phan (p < 0.01 on 2 patients) and pCT-CBCT pop (NS), respectively.Conclusions. CBCT can be used for patient setup with either MRI or pCT as reference. The correctness of pCT can be verified from CBCT using a population-based calibration curve in the treatment geometry.
引用
收藏
页码:1496 / 1500
页数:5
相关论文
共 16 条
[1]   Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain [J].
Andreasen, Daniel ;
Van Leemput, Koen ;
Hansen, Rasmus H. ;
Andersen, Jon A. L. ;
Edmund, Jens M. .
MEDICAL PHYSICS, 2015, 42 (04) :1596-1605
[2]   Clinical evaluation of 3D/3D MRI-CBCT automatching on brain tumors for online patient setup verification - A step towards MRI-based treatment planning [J].
Buhl, Sune K. ;
Duun-Christensen, Anne K. ;
Kristensen, Brian H. ;
Behrens, Claus F. .
ACTA ONCOLOGICA, 2010, 49 (07) :1085-1091
[3]  
Crawley M. J., 2007, R BOOK
[4]   Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients:: accuracy, reproducibility and consistency [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Cosnard, G ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :237-245
[5]  
Eclipse Reference guide, 2013, ECL REF GUID RES SMA
[6]   A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times [J].
Edmund, Jens M. ;
Kjer, Hans M. ;
Van Leemput, Koen ;
Hansen, Rasmus H. ;
Andersen, Jon A. L. ;
Andreasen, Daniel .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) :7501-7519
[7]  
International Commission on Radiation Units and Measurements (ICRU), 1987, 42 ICRU
[8]   Improved quality of computed tomography substitute derived from magnetic resonance (MR) data by incorporation of spatial information - potential application for MR-only radiotherapy and attenuation correction in positron emission tomography [J].
Johanson, Adam ;
Garpebring, Anders ;
Karlsson, Mikael ;
Asklund, Thomas ;
Nyholm, Tufve .
ACTA ONCOLOGICA, 2013, 52 (07) :1369-1373
[9]   T1/T2☆-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning [J].
Kapanen, Mika ;
Tenhunen, Mikko .
ACTA ONCOLOGICA, 2013, 52 (03) :612-618
[10]   A comparison of clinical target volumes determined by CT and MRI for the radiotherapy planning of base of skull meningiomas [J].
Khoo, VS ;
Adams, EJ ;
Saran, F ;
Bedford, JL ;
Perks, JR ;
Warrington, AP ;
Brada, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (05) :1309-1317