Passive magnetic shielding in static gradient fields

被引:25
作者
Bidinosti, C. P. [1 ]
Martin, J. W. [1 ]
机构
[1] Univ Winnipeg, Dept Phys, Winnipeg, MB R3B 2E9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
DESIGN; COILS;
D O I
10.1063/1.4873714
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The effect of passive magnetic shielding on dc magnetic field gradients imposed by both external and internal sources is studied for two idealized shield models: concentric spherical and infinitely-long cylindrical shells of linear material. It is found that higher-order multipoles of an externally applied magnetic field are always shielded progressively better for either geometry by a factor related to the order of the multipole. In regard to the design of internal coil systems, we determine reaction factors for the general multipole field and provide examples of how one can take advantage of the coupling of the coils to the innermost shell to optimize the uniformity of the field. Furthermore, we provide formulae relevant to active magnetic compensation systems which attempt to stabilize the interior fields by sensing and cancelling the exterior fields close to the outermost shell. Overall this work provides a comprehensive framework that is useful for the analysis and optimization of dc magnetic shields, serving as a theoretical and conceptual design guide as well as a starting point and benchmark for finite-element analysis. (C) 2014 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:15
相关论文
共 42 条
[1]  
[Anonymous], 1999, CLASSICAL ELECTRODYN
[2]   Electric dipole moment searches: Effect of linear electric field frequency shifts induced in confined gases [J].
Barabanov, A. L. ;
Golub, R. ;
Lamoreaux, S. K. .
PHYSICAL REVIEW A, 2006, 74 (05)
[3]   Selective passive shielding and the Faraday bracelet [J].
Bidinosti, C. P. ;
Hayden, M. E. .
APPLIED PHYSICS LETTERS, 2008, 93 (17)
[4]   Active shielding of cylindrical saddle-shaped coils: Application to wire-wound RF coils for very low field NMR and MRI [J].
Bidinosti, CP ;
Kravchuk, IS ;
Hayden, ME .
JOURNAL OF MAGNETIC RESONANCE, 2005, 177 (01) :31-43
[5]  
Bork J., 2000, P 12 INT C BIOM
[6]   Magnetic field stabilization for magnetically shielded volumes by external field coils [J].
Brys, T ;
Czekaj, S ;
Daum, M ;
Fierlinger, P ;
George, D ;
Henneck, R ;
Kasprzak, M ;
Kirch, K ;
Kuzniak, M ;
Kuehne, G ;
Pichlmaier, A ;
Siodmok, A ;
Szelc, A ;
Tanner, L ;
Assmann, C ;
Bechstein, S ;
Drung, D ;
Schurig, T ;
Ciofi, C ;
Neri, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 554 (1-3) :527-539
[7]   Optical magnetometry [J].
Budker, Dmitry ;
Romalis, Michael .
NATURE PHYSICS, 2007, 3 (04) :227-234
[8]   Optimal three-layer cylindrical magnetic shield sets for scientific applications [J].
Burt, EA ;
Ekstrom, CR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (07) :2699-2704
[9]  
COHEN D, 2002, P 13 INT C BIOM