Percutaneous Image-Guided Anterior Screw Fixation of the Odontoid Process

被引:4
作者
Autrusseau, Pierre-Alexis [1 ]
Heidelberg, Damien [2 ]
Stacoffe, Nicolas [2 ]
Dalili, Danoob [3 ,4 ]
Cazzato, Roberto Luigi [1 ]
Koch, Guillaume [1 ]
Gangi, Afshin [1 ]
Garnon, Julien [1 ]
机构
[1] Hop Univ Strasbourg, Serv Imagerie Intervent, 1 Pl Hop, F-67000 Strasbourg, France
[2] Hosp Civils Lyon, Serv Imagerie Intervent, 3 Quai Celestins, F-69002 Lyon, France
[3] Oxford Univ Hosp NHS Fdn Trust, Nuffield Orthopaed Ctr, Windmill Rd, Oxford OX3 7LD, England
[4] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
关键词
Percutaneous; C2; Odontoid process; Screw fixation; Hydrodissection; FRACTURES; CT;
D O I
10.1007/s00270-020-02734-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To describe the technique of percutaneous image-guided anterior screw fixation of the odontoid process in five patients using hydrodissection of the jugulo-carotid and pre-vertebral spaces. Methods and Materials Between 03/2018 and 03/2020, five patients from two university hospitals underwent a percutaneous image-guided anterior screw fixation of the odontoid process for one pathological fracture, two impending fractures and two traumatic fractures of the dens. Technical success was defined as a satisfactory positioning of the screw in the odontoid. Detailed data with the number and type of needles required, the time to perform hydrodissection, the volume of fluid used, the time for bone access, the size and lengths of the screws used, technical success, complications, clinical outcomes and follow-up were retrospectively assessed. Results Technical success was achieved in 100% (5/5 cases), with a mean volume of hydrodissection of 218 +/- 8.4 mL (range 210-230). Mean total procedure time was 112 +/- 34 min (range 70-160). The lengths of the screws ranged from 30 mm to 55 mm. Additional cementoplasty was performed in the three malignant cases. VAS scores dropped on a 10-point scale from mean 5.8 +/- 2.2 pre-procedure to 0.8 +/- 0.4 after the procedure. No major complication occurred. Conclusion Percutaneous image-guided anterior screw fixation of the odontoid process using hydrodissection of the jugulo-carotid and pre-vertebral spaces is technically feasible and seems safe.
引用
收藏
页码:647 / 653
页数:7
相关论文
共 12 条
[11]   The role of polymethylmethacrylate bone cement in modern orthopaedic surgery [J].
Webb, J. C. J. ;
Spencer, R. F. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (07) :851-857
[12]   Anterior retropharyngeal approach to C1 for percutaneous vertebroplasty under C-arm fluoroscopy [J].
Yang, Jun-Song ;
Chu, Lei ;
Xiao, Fu-Tao ;
Zhang, Dong-Jie ;
Wang, Yang ;
Chen, Liang ;
Ke, Zhen-Yong ;
Hao, Ding-Jun ;
Deng, Zhong-Liang .
SPINE JOURNAL, 2015, 15 (03) :539-545