Accuracy estimation of the 16O2+ transition frequencies targeting the search for the variation in the proton-electron mass ratio

被引:17
作者
Kajita, Masatoshi [1 ]
机构
[1] Natl Inst Informat & Commun Technol, Koganei, Tokyo 1848795, Japan
基金
日本学术振兴会;
关键词
Accuracy estimation - Coulomb crystals - Electric quadrupoles - Heteronuclear diatomic molecule - High sensitivity - Radial direction - Systematic uncertainties - Transition frequencies;
D O I
10.1103/PhysRevA.95.023418
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We estimate the Stark and Zeeman shifts in the transition frequencies of the O-16(2)+ molecular ion as a step in the search for the variation in the proton-to-electron mass ratio mu. The X-2 Pi nu = 21- a(4)Pi v = 0 or the X-2 Pi v = 21- a(4)Pi v = 1 transition frequencies (THz region) of the O-16(2)+ molecular ion have particularly high sensitivity to the variation in mu. Note also that the Stark shift in the O-16(2)+ transition frequencies is expected to be much smaller than that for heteronuclear diatomic molecules. However, the actual systematic uncertainties for the O-16(2)+ transition frequencies have never been estimated. We estimated the Stark and Zeeman shifts in the different O-16(2)+ transition frequencies. When the molecular ions in a string crystal formed in a linear trap (trap electric field <0.1 V/cm, and Stark shift <10(-20)) are used, the X-2 Pi(1/2) (v,J) = (0,1/2)- (nu',1/2)(v' >= 1) transition frequencies are most advantageous for the search for the variation in mu(Delta mu/mu < 10(-17)) because the Zeeman shift is easily suppressed to lower than 10(-18) and the electric quadrupole shift is zero. On the other hand, the X-2 Pi(1/2)(v, J) = (21,1/2)- a(4)Pi(1/2)(v,J) = (0,1/2) transition frequency has another merit in that the positive Stark shift induced by the trap electric field can be canceled by the quadratic Doppler shift. Therefore, the measurement using molecular ions in a Coulomb crystal broadened in the radial direction is also possible, when the Zeeman shift is effectively eliminated.
引用
收藏
页数:6
相关论文
共 34 条
  • [1] Relativistic effects in two valence-electron atoms and ions and the search for variation of the fine-structure constant
    Angstmann, EJ
    Dzuba, VA
    Flambaum, VV
    [J]. PHYSICAL REVIEW A, 2004, 70 (01): : 014102 - 1
  • [2] [Anonymous], MICROWAVE SPECTROSCO
  • [3] The cosmological evolution of the nucleon mass and the electroweak coupling constants
    Calmet, X
    Fritzsch, H
    [J]. EUROPEAN PHYSICAL JOURNAL C, 2002, 24 (04): : 639 - 642
  • [4] Frequency Comparison of Two High-Accuracy Al+ Optical Clocks
    Chou, C. W.
    Hume, D. B.
    Koelemeij, J. C. J.
    Wineland, D. J.
    Rosenband, T.
    [J]. PHYSICAL REVIEW LETTERS, 2010, 104 (07)
  • [5] Dirac P.A.M., 1937, Nature, V139, P323
  • [6] Production of a rovibrationally selected O2+ beam for dissociative recombination studies
    Dochain, A.
    Urbain, X.
    [J]. DR2013: NINTH INTERNATIONAL CONFERENCE ON DISSOCIATIVE RECOMBINATION: THEORY, EXPERIMENT, AND APPLICATIONS, 2015, 84
  • [7] High-Accuracy Measurement of the Differential Scalar Polarizability of a 88Sr+ Clock Using the Time-Dilation Effect
    Dube, Pierre
    Madej, Alan A.
    Tibbo, Maria
    Bernard, John E.
    [J]. PHYSICAL REVIEW LETTERS, 2014, 112 (17)
  • [8] Germann M, 2014, NAT PHYS, V10, P820, DOI [10.1038/nphys3085, 10.1038/NPHYS3085]
  • [9] FRANCK-CONDON FACTORS, R-CENTROIDS, ELECTRONIC-TRANSITION MOMENTS, AND EINSTEIN COEFFICIENTS FOR MANY NITROGEN AND OXYGEN BAND SYSTEMS
    GILMORE, FR
    LAHER, RR
    ESPY, PJ
    [J]. JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1992, 21 (05) : 1005 - 1107
  • [10] Frequency Ratio of Two Optical Clock Transitions in 171Yb+ and Constraints on the Time Variation of Fundamental Constants
    Godun, R. M.
    Nisbet-Jones, P. B. R.
    Jones, J. M.
    King, S. A.
    Johnson, L. A. M.
    Margolis, H. S.
    Szymaniec, K.
    Lea, S. N.
    Bongs, K.
    Gill, P.
    [J]. PHYSICAL REVIEW LETTERS, 2014, 113 (21)