Rapid and reliable diagnostic method to detect Zika virus by real-time fluorescence reverse transcription loop-mediated isothermal amplification

被引:16
作者
Guo, Xu-Guang [1 ,2 ]
Zhou, Yong-Zhuo [3 ]
Li, Qin [4 ]
Wang, Wei [5 ,6 ]
Wen, Jin-Zhou [7 ]
Zheng, Lei [1 ]
Wang, Qian [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Lab Med Ctr, Guangzhou 510515, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Dept Clin Lab Med, Affiliated Hosp 3, Guangzhou 510150, Guangdong, Peoples R China
[3] Southern Med Univ, Dept Clin Lab Med, Affiliated Hosp 3, Guangzhou 510150, Guangdong, Peoples R China
[4] Yale Univ, Yale Sch Med, Dept Med, Sect Pulm Crit Care & Sleep Med, New Haven, CT 06520 USA
[5] Shenzhen Univ, Dept Lab Med, Affiliated Hosp 1, Shenzhen 518035, Guangdong, Peoples R China
[6] Shenzhen Second Peoples Hosp, Dept Lab Med, Shenzhen 518035, Guangdong, Peoples R China
[7] Ctr Dis Control & Prevent Chaozhou, Guangzhou 521000, Guangdong, Peoples R China
关键词
Zika virus; NS5; gene; LAMP; Loop-mediated isothermal amplification; Real-time fluorescence reverse transcription; MOLECULAR DIAGNOSIS; INFECTIOUS-DISEASES; LAMP;
D O I
10.1186/s13568-018-0591-6
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To detect Zika virus more rapidly and accurately, we developed a novel method that utilized a real-time fluorescence reverse transcription loop-mediated isothermal amplification (LAMP) technique. The NS5 gene was amplified by a set of six specific primers that recognized six distinct sequences. The amplification process, including 60 min of thermostatic reaction with Bst DNA polymerase following real-time fluorescence reverse transcriptase using genomic Zika virus standard strain (MR766), was conducted through fluorescent signaling. Among the six pairs of primers that we designate here, NS5 was the most efficient with a high sensitivity of up to 3.3 ng/mu l and reproducible specificity on eight pathogen samples that were used as negative controls. The real-time fluorescence reverse transcription LAMP detection process can be completed within 35 min. Our study demonstrated that real-time fluorescence reverse transcription LAMP could be highly beneficial and convenient clinical application to detect Zika virus due to its high specificity and stability.
引用
收藏
页数:8
相关论文
共 24 条
[1]   Loop-mediated isothermal amplification (LAMP) for malarial parasites of humans: Would it come to clinical reality as a point-of-care test? [J].
Abdul-Ghani, Rashad ;
Al-Mekhlafi, Abdulsalam M. ;
Karanis, Panagiotis .
ACTA TROPICA, 2012, 122 (03) :233-240
[2]   Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: A review [J].
Ahmad, Farhan ;
Hashsham, Syed A. .
ANALYTICA CHIMICA ACTA, 2012, 733 :1-15
[3]   Miniaturized isothermal nucleic acid amplification, a review [J].
Asiello, Peter J. ;
Baeumner, Antje J. .
LAB ON A CHIP, 2011, 11 (08) :1420-1430
[4]   Molecular diagnosis of respiratory viruses [J].
Beck, Eric T. ;
Henrickson, Kelly J. .
FUTURE MICROBIOLOGY, 2010, 5 (06) :901-916
[5]   Why Zika virus infection has become a public health concern? [J].
Chen, Hui-Lan ;
Tang, Ren-Bin .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2016, 79 (04) :174-178
[6]  
Deborggraeve S, 2012, EXPERT REV MOL DIAGN, V12, P719, DOI [10.1586/ERM.12.72, 10.1586/erm.12.72]
[7]   Molecular Detection, Quantification, and Diversity Evaluation of Microalgae [J].
Ebenezer, Vinitha ;
Medlin, Linda K. ;
Ki, Jang-Seu .
MARINE BIOTECHNOLOGY, 2012, 14 (02) :129-142
[8]   Applications of Loop-Mediated Isothermal DNA Amplification [J].
Fu, Shijun ;
Qu, Guanggang ;
Guo, Shijin ;
Ma, Lin ;
Zhang, Na ;
Zhang, Songlin ;
Gao, Sanyang ;
Shen, Zhiqiang .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2011, 163 (07) :845-850
[9]   Nucleic acid isothermal amplification technologies - A review [J].
Gill, Pooria ;
Ghaemi, Amir .
NUCLEOSIDES NUCLEOTIDES & NUCLEIC ACIDS, 2008, 27 (03) :224-243
[10]   WHO's Chan warns over spread of Zika virus beyond Latin America [J].
Gulland, Anne .