A simple highly sensitive and selective aptamer-based colorimetric sensor for environmental toxins microcystin-LR in water samples

被引:127
作者
Li, Xiuyan [1 ]
Cheng, Ruojie [1 ]
Shi, Huijie [1 ]
Tang, Bo [1 ]
Xiao, Hanshuang [1 ]
Zhao, Guohua [1 ]
机构
[1] Tongji Univ, Dept Chem, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Microcystin-LR (MC-LR); Aptamer; Calorimetric sensor; High sensitivity; High selectivity; ELECTROCHEMICAL IMMUNOSENSOR; GOLD NANOPARTICLES; MASS-SPECTROMETRY; APTASENSOR; GRAPHENE; RR; CYANOBACTERIA; EXTRACTION; BIOSENSOR; ELECTRODE;
D O I
10.1016/j.jhazmat.2015.11.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and highly sensitive aptamer-based colorimetric sensor was developed for selective detection of Microcystin-LR (MC-LR). The aptamer (ABA) was employed as recognition element which could bind MC-LR with high-affinity, while gold nanoparticles (AuNPs) worked as sensing materials whose plasma resonance absorption peaks red shifted upon binding of the targets at a high concentration of sodium chloride. With the addition of MC-LR, the random coil aptamer adsorbed on Au NPs altered into regulated structure to form MC-LR-aptamer complexes and broke away from the surface of Au NPs, leading to the aggregation of AuNPs, and the color converted from red to blue due to the interparticle plasmon coupling. Results showed that our aptamer-based calorimetric sensor exhibited rapid and sensitive detection performance for MC-LR with linear range from 0.5 nM to 7.5 mu M and the detection limit reached 0.37 nM. Meanwhile, the pollutants usually coexisting with MC-LR in pollutant water samples had not demonstrated disturbance for detecting of MC-LR. The mechanism was also proposed suggesting that high affinity interaction between aptamer and MC-LR significantly enhanced the sensitivity and selectivity for MC-LR detection. Besides, the established method was utilized in analyzing real water samples and splendid sensitivity and selectivity were obtained as well. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:474 / 480
页数:7
相关论文
共 34 条
[11]   A Fetomolar Level 17β-estradiol Electrochemical Aptasensor Constructed On Hierachical Dendritic Gold Modified Boron-Doped Diamond Electrode [J].
Ke, Hongyang ;
Liu, Meichuan ;
Zhuang, Lu ;
Li, Zhengxin ;
Fan, Lifang ;
Zhao, Guohua .
ELECTROCHIMICA ACTA, 2014, 137 :146-153
[12]   Electrochemical detection of 17β-estradiol using DNA aptamer immobilized gold electrode chip [J].
Kim, Yeon Seok ;
Jung, Ho Sup ;
Matsuura, Toshihiko ;
Lee, Hea Yeon ;
Kawai, Tomoji ;
Gu, Man Bock .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2525-2531
[13]   Sensitive and Selective Colorimetric Visualization of Cerebral Dopamine Based on Double Molecular Recognition [J].
Kong, Biao ;
Zhu, Anwei ;
Luo, Yongping ;
Tian, Yang ;
Yu, Yanyan ;
Shi, Guoyue .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (08) :1837-1840
[14]   Label-free colorimetric detection of specific sequences in genomic DNA amplified by the polymerase chain reaction [J].
Li, HX ;
Rothberg, LJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (35) :10958-10961
[15]   Electrochemical immunosensor for ultrasensitive detection of microcystin-LR based on graphene-gold nanocomposite/functional conducting polymer/gold nanoparticle/ionic liquid composite film with electrodeposition [J].
Li Ruiyi ;
Xia Qianfang ;
Li Zaijun ;
Sun Xiulan ;
Liu Junkang .
BIOSENSORS & BIOELECTRONICS, 2013, 44 :235-240
[16]   Determination of microcystin-LR in water by a label-free aptamer based electrochemical impedance biosensor [J].
Lin, Zhenyu ;
Huang, Huiming ;
Xu, Yixiang ;
Gao, Xiaoyao ;
Qiu, Bin ;
Chen, Xi ;
Chen, Guonan .
TALANTA, 2013, 103 :371-374
[17]  
Liu J., 2005, ANGEW CHEM, V118, P96
[18]   Colloidal Graphene as a Transducer in Homogeneous Fluorescence-Based Immunosensor for Rapid and Sensitive Analysis of Microcystin-LR [J].
Liu, Meng ;
Zhao, Huimin ;
Chen, Shuo ;
Yu, Hongtao ;
Quan, Xie .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (22) :12567-12574
[19]   Extinction coefficient of gold nanoparticles with different sizes and different capping ligands [J].
Liu, Xiong ;
Atwater, Mark ;
Wang, Jinhai ;
Huo, Qun .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2007, 58 (01) :3-7
[20]   Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples [J].
Long, F. ;
He, M. ;
Zhu, A. N. ;
Shi, H. C. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) :2346-2351