Microfluidic Concentration-Enhanced Cellular Kinase Activity Assay

被引:67
作者
Lee, Jeong Hoon [1 ]
Cosgrove, Benjamin D. [2 ]
Lauffenburger, Douglas A. [2 ]
Han, Jongyoon [1 ,2 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Dept Biol Engn, Cambridge, MA 02139 USA
关键词
PRECONCENTRATION; CELLS; SENSITIVITY; DYNAMICS; DEVICE;
D O I
10.1021/ja902594f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, we reported a simple, disposable PDMS micro/nanofluidic preconcentration chip for in vitro concentration-enhanced cell kinase assays. Utilizing the preconcentration (etectrokinetic trapping) directly from cell lysate (1 mM ATP) samples, we could achieve at least a 25-fold increase in reaction velocity and 65-fol.d enhancement in sensitivity. In addition, we shorten the assay time down to less than 10 min, with the sample volume requirements of down to similar to 5 cells. This device could be a generic and powerful tool for diagnostics and systems biology studies at the single-cell level, if property optimized and integrated with the cell culture microdevices.
引用
收藏
页码:10340 / +
页数:4
相关论文
共 15 条
[1]   Collecting and organizing systematic sets of protein data [J].
Albeck, John G. ;
MacBeath, Gavin ;
White, Forest M. ;
Sorger, Peter K. ;
Lauffenburger, Douglas A. ;
Gaudet, Suzanne .
NATURE REVIEWS MOLECULAR CELL BIOLOGY, 2006, 7 (11) :803-812
[2]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412
[3]   Single cell profiling of potentiated phospho-protein networks in cancer cells [J].
Irish, JM ;
Hovland, R ;
Krutzik, PO ;
Perez, OD ;
Bruserud, O ;
Gjertsen, BT ;
Nolan, GP .
CELL, 2004, 118 (02) :217-228
[4]   Dynamics of the p53-Mdm2 feedback loop in individual cells [J].
Lahav, G ;
Rosenfeld, N ;
Sigal, A ;
Geva-Zatorsky, N ;
Levine, AJ ;
Elowitz, MB ;
Alon, U .
NATURE GENETICS, 2004, 36 (02) :147-150
[5]   Increase of reaction rate and sensitivity of low-abundance enzyme assay using micro/nanofluidic preconcentration chip [J].
Lee, Jeong Hoon ;
Song, Yong-Ak ;
Tannenbaum, Steven R. ;
Han, Jongyoon .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3198-3204
[6]   Multiplexed proteomic sample preconcentration device using surface-patterned ion-selective membrane [J].
Lee, Jeong Hoon ;
Song, Yong-Ak ;
Han, Jongyoon .
LAB ON A CHIP, 2008, 8 (04) :596-601
[7]   Measurement of kinase activation in single mammalian cells [J].
Meredith, GD ;
Sims, CE ;
Soughayer, JS ;
Allbritton, NL .
NATURE BIOTECHNOLOGY, 2000, 18 (03) :309-312
[8]   Early single cell bifurcation of pro- and antiapoptotic states during oxidative stress [J].
Nair, VD ;
Yuen, T ;
Olanow, CW ;
Sealfon, SC .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2004, 279 (26) :27494-27501
[9]   Oscillations in NF-κB signaling control the dynamics of gene expression [J].
Nelson, DE ;
Ihekwaba, AEC ;
Elliott, M ;
Johnson, JR ;
Gibney, CA ;
Foreman, BE ;
Nelson, G ;
See, V ;
Horton, CA ;
Spiller, DG ;
Edwards, SW ;
McDowell, HP ;
Unitt, JF ;
Sullivan, E ;
Grimley, R ;
Benson, N ;
Broomhead, D ;
Kell, DB ;
White, MRH .
SCIENCE, 2004, 306 (5696) :704-708
[10]   Measurement of enzyme kinetics using a continuous-flow microfluidic system [J].
Seong, GH ;
Heo, J ;
Crooks, RM .