A label-free double-amplification system for sensitive detection of single-stranded DNA and thrombin by liquid chromatography-mass spectrometry

被引:8
作者
Zhao, Wenbo [1 ]
Qin, Zhen [1 ]
Zhang, Chengsen [1 ]
Zhao, Meiping [1 ]
Luo, Hai [1 ]
机构
[1] Peking Univ, Coll Chem & Mol Engn, MOE Key Lab Bioorgan Chem & Mol Engn, Beijing Natl Lab Mol Sci, Beijing 100871, Peoples R China
关键词
EXONUCLEASE-III; SIGNAL AMPLIFICATION; RECYCLING AMPLIFICATION; BIOSENSOR; APTAMER; ASSAY; PROTEOMICS; STRATEGY;
D O I
10.1039/c4cc03559c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A label-free double amplification system has been developed by using a ternary DNA probe containing the poly(adenine-thymine) sequence assisted by exonuclease III degradation. The method achieved more than 600-fold signal amplification and allowed sensitive detection of single-stranded DNA and thrombin at the pM level by using liquid chromatography/mass spectrometry.
引用
收藏
页码:9846 / 9848
页数:3
相关论文
共 48 条
  • [31] Label-free sensitive detection of MUC1 using a liquid crystal based-system
    Duong, Thai Duong Song
    Jang, Chang-Hyun
    LIQUID CRYSTALS, 2020, 47 (12) : 1784 - 1793
  • [32] Target-triggered activation of rolling circle amplification for label-free and sensitive fluorescent uracil-DNA glycosylase activity detection and inhibition
    Yang, Fang
    Li, Xia
    Li, Jing
    Xiang, Yun
    Yuan, Ruo
    TALANTA, 2019, 204 : 812 - 816
  • [33] Copper nanocluster as a fluorescent indicator for label-free and sensitive detection of DNA hybridization assisted with a cascade isothermal exponential amplification reaction
    Zhang, Xingxing
    Jin, Yan
    Li, Baoxin
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (07) : 5178 - 5184
  • [34] A cascade signal amplification strategy for sensitive and label-free DNA detection based on Exo III-catalyzed recycling coupled with rolling circle amplification
    Liu, Xingti
    Xue, Qingwang
    Ding, Yongshun
    Zhu, Jing
    Wang, Lei
    Jiang, Wei
    ANALYST, 2014, 139 (11) : 2884 - 2889
  • [35] Plasma proteomic analysis of systemic lupus erythematosus patients using liquid chromatography/tandem mass spectrometry with label-free quantification
    Madda, Rashmi
    Lin, Shih-Chang
    Sun, Wei-Hsin
    Huang, Shir-Ly
    PEERJ, 2018, 6
  • [36] Label-free and sensitive detection of T4 polynucleotide kinase activity via coupling DNA strand displacement reaction with enzymatic-aided amplification
    Cheng, Rui
    Tao, Mangjuan
    Shi, Zhilu
    Zhang, Xiafei
    Jin, Yan
    Li, Baoxin
    BIOSENSORS & BIOELECTRONICS, 2015, 73 : 138 - 145
  • [37] Sensitive, enzyme-free and label-free electrochemical sensor for K-ras G12D point mutation detection based on double cascade amplification reaction
    Zhou, Xiaomei
    Liu, Xiaoyu
    Xia, Xinyu
    Yang, Xiaoyan
    Xiang, Hua
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 870
  • [38] A Single-Substrate Biosensor with Spin-Coated Liquid Crystal Film for Simple, Sensitive and Label-Free Protein Detection
    Wu, Po-Chang
    Pai, Chao-Ping
    Lee, Mon-Juan
    Lee, Wei
    BIOSENSORS-BASEL, 2021, 11 (10):
  • [39] A dichromatic label-free aptasensor for sulfadimethoxine detection in fish and water based on AuNPs color and fluorescent dyeing of double-stranded DNA with SYBR Green I
    Chen, Xiang-Xiu
    Lin, Zheng-Zhong
    Hong, Cheng-Yi
    Yao, Qiu-Hong
    Huang, Zhi-Yong
    FOOD CHEMISTRY, 2020, 309
  • [40] Proteomic analysis of rat plasma with experimental autoimmune uveitis based on label-free liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Guo, Dadong
    Gu, Peiming
    Liu, Zhengfeng
    Tang, Kai
    Du, Yuxiang
    Bi, Hongsheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 976 : 84 - 90