Development and validation of a fast and reliable method for the quantification of glucagon by liquid chromatography and tandem mass spectrometry

被引:7
作者
Farre-Segura, Jordi [1 ]
Fabregat-Cabello, Neus [1 ]
Calaprice, Chiara [1 ]
Nyssen, Laurent [1 ]
Peeters, Stephanie [1 ]
Le Goff, Caroline [1 ]
Cavalier, Etienne [1 ]
机构
[1] Univ Liege, CHU Liege, Dept Clin Chem, Liege, Belgium
关键词
Liquid chromatography; Mass spectrometry; Glucagon; LC-MS/MS; QUANTITATION; SENSITIVITY; GLP-1;
D O I
10.1016/j.cca.2020.11.004
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: The quantitation of glucagon remains a challenging immunoassay, mainly due to cross-reactivity. A sensitive, rapid and specific intact glucagon method is therefore necessary for quality routine analysis. A tandem mass spectrometry method to fulfill this objective is described in this work. Methods: Glucagon was extracted from plasma employing a mixed-mode anion exchange solid-phase extraction. Sample stability was assessed in K2-EDTA and P800 tubes at different temperatures. We compared our method to two different immunoassays. FDA and EMA guidelines were followed for validation. An external quality control program served for comparison with other laboratories. Results: Assay imprecision was below 4%. Recoveries were within 95-103%. LoQ was 8.75 pg/mL. Total analytical CV was 2.91%. Samples were found stable at 4 degrees C for less than 4 h. Diasource (R) RIA disagreed with our method. Mercodia (R) ELISA provided a closer agreement, also proven by external quality control samples. Conclusions: A rapid and specific LC-MS/MS method for glucagon quantitation has been developed, validated and is suitable to routine care. The simplicity and the good performances in terms of time and specificity, could open the possibility to establish a standardized method for glucagon.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 23 条
[1]   The biology of glucagon and the consequences of hyperglucagonemia [J].
Albrechtsen, Nicolai J. Wewer ;
Kuhre, Rune E. ;
Pedersen, Jens ;
Knop, Filip K. ;
Holst, Jens J. .
BIOMARKERS IN MEDICINE, 2016, 10 (11) :1141-1151
[2]   Specificity and sensitivity of commercially available assays for glucagon and oxyntomodulin measurement in humans [J].
Bak, Monika J. ;
Albrechtsen, Nicolai Wewer ;
Pedersen, Jens ;
Hartmann, Bolette ;
Christensen, Mikkel ;
Vilsboll, Tina ;
Knop, Filip K. ;
Deacon, Carolyn F. ;
Dragsted, Lars O. ;
Holst, Jens J. .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2014, 170 (04) :529-538
[3]  
Bureau International des Poids et Mesures BIPM, 2008, JCGM, V100
[4]   Considerations in parathyroid hormone testing [J].
Cavalier, Etienne ;
Plebani, Mario ;
Delanaye, Pierre ;
Souberbielle, Jean-Claude .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (12) :1913-1919
[5]  
CLSI, 2014, Evaluation of precision of quantitative measurement procedures, V3rd
[6]   Quantitation of the large polypeptide glucagon by protein precipitation and LC/MS [J].
Delinsky, DC ;
Hill, KT ;
White, CA ;
Bartlett, MG .
BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (09) :700-705
[7]   The metabolic actions of glucagon revisited [J].
Habegger, Kirk M. ;
Heppner, Kristy M. ;
Geary, Nori ;
Bartness, Timothy J. ;
DiMarchi, Richard ;
Tschoep, Matthias H. .
NATURE REVIEWS ENDOCRINOLOGY, 2010, 6 (12) :689-697
[8]  
Horowitz GL, 2010, EP28 A3C DEFINING ES
[9]   Development of a UHPLC-MS/MS (SRM) method for the quantitation of endogenous glucagon and dosed GLP-1 from human plasma [J].
Howard, James W. ;
Kay, Richard G. ;
Jones, Ben ;
Cegla, Jaimini ;
Tan, Tricia ;
Bloom, Steve ;
Creaser, Colin S. .
BIOANALYSIS, 2017, 9 (09) :733-751
[10]   Identification of plasma protease derived metabolites of glucagon and their formation under typical laboratory sample handling conditions [J].
Howard, James W. ;
Kay, Richard G. ;
Tan, Tricia ;
Minnion, James ;
Creaser, Colin S. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (02) :171-181