A new method for generating poroelastograms in noisy environments

被引:15
作者
Righetti, Raffaella
Ophir, Jonathan
Garra, Brian S.
Chandrasekhar, Rajah M.
Krouskop, Thomas A.
机构
[1] Univ Texas, Sch Med, Dept Diagnost & Intervent Imaging, Ultrason Lab, Houston, TX 77030 USA
[2] Univ Vermont, Coll Med, Dept Radiol, Burlington, VT USA
[3] Baylor Coll Med, Dept Phys Med & Rehabil, Houston, TX 77030 USA
关键词
elastography; clastogram; imaging; lymphedema; permeability; Poisson's ratio; poroelastography; poroelastogram; porous media; strain ratio; ultrasound;
D O I
10.1177/016173460502700401
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Poroelastography has been recently introduced as a new elastographic technique that may be used to describe the spatial and temporal behavior of poroelastic materials. The experimental methodology proposed thus far for phantoms and tissues in vitro requires the acquisition of a precompression rf frame, the application of a unit step strain compression to the sample and the acquisition of subsequent post-compression frames from the material. Elastograms and poroelastograms are generated by cross-correlating the sequentially-acquired postcompression frames with the reference precompression frame. The application of poroelastography to tissues in vivo must address the echo decorrelation problems that are encountered due to uncontrolled tissue motion, which may become significant shortly after the acquisition of the precompression frame. In this paper, we investigate the feasibility of per-forming poroelastography experiments using an alternative experimental scheme. In the proposed experimental methodology, the reference precompression frame is continuously moved while the time interval between the frames that are correlated is kept short. This allows long data acquisition times with simultaneous minimization of the decorrelation due to undesired tissue motion in vivo. We validated this new method using both a step and a ramp compression functions. We performed poroelastographic simulations and experiments in phantoms and in tissues in vivo. The results were compared to those obtained using the traditional acquisition methodology. This study shows that the two methods yield similar results in vitro and suggests that the new method may be more robust to decorrelation noise in applications in vivo.
引用
收藏
页码:201 / 220
页数:20
相关论文
共 35 条
[1]  
ARMSTRONG CG, 1984, J BIOMECH ENG-T ASME, V106, P165, DOI 10.1115/1.3138475
[2]   INTERSPECIES COMPARISONS OF INSITU INTRINSIC MECHANICAL-PROPERTIES OF DISTAL FEMORAL CARTILAGE [J].
ATHANASIOU, KA ;
ROSENWASSER, MP ;
BUCKWALTER, JA ;
MALININ, TI ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (03) :330-340
[3]  
Bendat JS., 2011, RANDOM DATA ANAL MEA
[4]  
BERRY GP, 2005, P 4 INT C ULTR MEAS, P97
[5]  
CHANDRASEKHAR RM, IN PRESS ULTRASOUND
[6]   Dynamic measurement of internal solid displacement in articular cartilage using ultrasound backscatter [J].
Fortin, M ;
Buschmann, MD ;
Bertrand, MJ ;
Foster, FS ;
Ophir, J .
JOURNAL OF BIOMECHANICS, 2003, 36 (03) :443-447
[7]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[8]   The relationship of problems in biomedical MRI to the study of porous media [J].
Gore, JC ;
Anderson, AW ;
Does, MD ;
Gochberg, DF ;
Joers, JM ;
Kennan, RP ;
Parsons, EC ;
Schachter, M .
MAGNETIC RESONANCE IMAGING, 2001, 19 (3-4) :295-300
[9]   In vivo real-time freehand palpation imaging [J].
Hall, TJ ;
Zhu, YN ;
Spalding, CS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03) :427-435
[10]   INDENTATION TESTS OF HUMAN ARTICULAR-CARTILAGE [J].
HORI, RY ;
MOCKROS, LF .
JOURNAL OF BIOMECHANICS, 1976, 9 (04) :259-268