Seismic vibration control of building structures with multiple tuned mass damper floors integrated

被引:84
|
作者
Xiang, Ping [1 ]
Nishitani, Akira [1 ]
机构
[1] Waseda Univ, Dept Architecture, Tokyo 1698555, Japan
来源
关键词
TMD floor system; floor isolation system; multimode approach; optimum design; tuned mass damper; PERFORMANCE; DESIGN;
D O I
10.1002/eqe.2379
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Floor isolation system (FIS) achieving very small floor accelerations has been used to ensure human comfortability or protect important equipments in buildings. Tuned mass damper (TMD) with large mass ratios has been demonstrated to be robust with respect to the changes in structural properties. This paper presents the concept of a TMD floor vibration control system, which takes advantages of both the FIS and TMD. Such a system is called 'TMD floor system' herein. The TMD floor system (TMDFS) in which building floors serve as TMDs can achieve large mass ratio without additional masses. Furthermore, multiple TMD floors installed in a building can control multimode vibrations. Then, an optimal design process, where the objective function is set as the maximum magnitude of the frequency response functions of inter-storey drifts, is proposed to determine the TMD floor parameters. Additionally, the multimode approach is applied to determine the optimal locations of TMD floors if not all of the floors in a building can serve as TMDs. In addition to the numerical simulations, a scaled model shaking table experiment is also conducted. Both the numerical and experimental results show that the absolute accelerations of the TMD floors are smaller than those of the main structural storeys, which indicates the TMDFS maintains the merit of FIS while greatly reducing seismic responses of main structures. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:909 / 925
页数:17
相关论文
共 50 条
  • [31] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Ji-Hwan Shin
    Moon K. Kwak
    Soo-Min Kim
    Kwang-Hyun Baek
    Journal of Mechanical Science and Technology, 2020, 34 : 5005 - 5015
  • [32] A Seismic vibration and damage control of high-rise structures with the implementation of a pendulum-type nontraditional tuned mass damper
    Xiang, Ping
    Nishitani, Akira
    Wu, Minger
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (12):
  • [33] Behavior of multiple tuned mass dampers for seismic response control of structures
    Xin, XZ
    Liu, L
    TIVC'2001: INTERNATIONAL SYMPOSIUM ON TRAFIC INDUCED VIBRATIONS & CONTROLS, 2001, : 75 - 82
  • [34] Seismic control of structure with phase control active tuned mass damper
    Lai, Yong-An
    Luo, Wei-Chen
    Huang, Shieh-Kung
    Yang, Cho-Yen
    Chang, Chia-Ming
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (07):
  • [35] Wind Induced Vibration Control and Energy Harvesting of Electromagnetic Resonant Shunt Tuned Mass-Damper-Inerter for Building Structures
    Luo, Yifan
    Sun, Hongxin
    Wang, Xiuyong
    Zuo, Lei
    Chen, Ning
    SHOCK AND VIBRATION, 2017, 2017
  • [36] Vibration Control of Structures by an Upgraded Tuned Liquid Column Damper
    Quoc Huong Cao
    JOURNAL OF ENGINEERING MECHANICS, 2021, 147 (09)
  • [37] Vibration control of structure using inelastic tuned mass damper
    Misal M.A.
    Manchalwar A.A.
    Nangare P.B.
    Asian Journal of Civil Engineering, 2024, 25 (6) : 4759 - 4770
  • [38] Vibration control of traveling crane with a novel tuned mass damper
    Liang, YW
    Xiong, SB
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 839 - 842
  • [39] Passive control of bilinear hysteretic structures by tuned mass damper for narrow band seismic motions
    Zhang, Z.
    Balendra, T.
    ENGINEERING STRUCTURES, 2013, 54 : 103 - 111
  • [40] Tuned Mass Damper for Vibration Control in Steel Jacket Platforms
    Golafshani, A. A.
    Gholizad, A.
    OMAE 2008: PROCEEDINGS OF THE 27TH INTERNATIONAL CONFERENCE ON OFFSHORE MECHANICS AND ARCTIC ENGINEERING - 2008, VOL 1, 2008, : 35 - 42