Pediatric clinical visual electrophysiology: a survey of actual practice

被引:27
作者
Fulton, Anne B.
Brecelj, Jelka
Lorenz, Birgit
Moskowitz, Anne
Thompson, Dorothy
Westall, Carol A.
机构
[1] Childrens Hosp, Dept Ophthalmol, Boston, MA 02115 USA
[2] Univ Ljubljana, Med Ctr, Eye Clin, Ljubljana, Slovenia
[3] Univ Regensburg, Dept Pediat Ophthalmol Strabismol & Ophthalmogene, D-8400 Regensburg, Germany
[4] Great Ormond St Hosp Sick Children, Dept Ophthalmol, London WC1N 3JH, England
[5] Univ Toronto, Hosp Sick Children, Dept Ophthalmol, Toronto, ON M5G 1X8, Canada
关键词
actual practice; electroretinogram; pediatric; survey; vsual electrophysiology; visual evoked potential;
D O I
10.1007/s10633-006-9029-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Survey the actual clinical practice of pediatric visual electrophysiology. The electrophysiologists surveyed were members of the International Society for Clinical Electrophysiology of Vision (ISCEV). Methods A self-administered questionnaire with 55 items about visual evoked potential (VEP) and electroretinogram (ERG) testing of pediatric patients was sent to ISCEV members. The survey queried personnel, facilities, referral patterns and conduct of tests. Results Nearly all respondents (94%) had advanced scientific or clinical degrees or both, and most (96%) worked in academic or medical facilities. Of the 71 respondents, 68 tested patients 12 years or younger, and nearly all of those performed both VEPs and ERGs. However, fewer than a third did high volume (> 10/ month) testing of infants and young children (<= 6 years). Eye care professionals and neurologists made the majority (57%) of the referrals, with the most common reason for referral being suspected visual impairment. Conduct of a pediatric test session often required more than one practitioner. For both VEP and ERG, more than 70% of respondents required at least 30 min for each test. The majority indicated that they followed the ISCEV standards for stimuli and data acquisition. Almost all ( 94%) reported using the ISCEV recommended VEP electrode configuration. For ERG, most (88%) used ocular contact electrodes ( including contact lens, thread, foil and HK loop), but 12% used skin electrodes exclusively and some (17%) used skin electrodes at times. Conclusions Pediatric ERG and VEP testing is a labor intensive endeavor of highly trained professionals. ISCEV technical standards are typically met or exceeded, indicating that high quality testing of infants and children is feasible. Revision of the ISCEV ERG standard is necessary to bring actual practice into accord with evidence-based recommendations for infant testing.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 52 条
[1]   STANDARDIZED FULL-FIELD ELECTRORETINOGRAPHY - NORMAL VALUES AND THEIR VARIATION WITH AGE [J].
BIRCH, DG ;
ANDERSON, JL .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (11) :1571-1576
[2]  
BIRCH EE, 1990, CLIN VISION SCI, V5, P363
[3]   Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults [J].
Bradshaw, K ;
Hansen, R ;
Fulton, A .
DOCUMENTA OPHTHALMOLOGICA, 2004, 109 (01) :43-55
[4]   From immature to mature pattern ERG and VEP [J].
Brecelj, J .
DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (03) :215-224
[5]   Pattern ERG and VEP maturation in schoolchildren [J].
Brecelj, J ;
Strucl, M ;
Zidar, I ;
Tekavcic-Pompe, M .
CLINICAL NEUROPHYSIOLOGY, 2002, 113 (11) :1764-1770
[6]   Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision [J].
Brigell, M ;
Bach, M ;
Barber, C ;
Moskowitz, A ;
Robson, J .
DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (02) :185-193
[7]   THE PRACTICE GUIDELINES DEVELOPMENT CYCLE - A CONCEPTUAL TOOL FOR PRACTICE GUIDELINES DEVELOPMENT AND IMPLEMENTATION [J].
BROWMAN, GP ;
LEVINE, MN ;
MOHIDE, EA ;
HAYWARD, RSA ;
PRITCHARD, KI ;
GAFNI, A ;
LAUPACIS, A .
JOURNAL OF CLINICAL ONCOLOGY, 1995, 13 (02) :502-512
[8]  
CARR RE, 1990, ELECTRODIAGNOSITIC T
[9]  
CONROY M, 1995, BRIT J GEN PRACT, V45, P371
[10]  
Coupland SG, 2006, PRINCIPLES PRACTICE, P245