Parametric Study on Effect of Adding Stiffener to Post-tensioned Steel Connection

被引:10
|
作者
Shiravand, M. R. [1 ]
Torabipour, A. [2 ]
Mahboubi, S. [1 ]
机构
[1] Shahid Beheshti Univ, Dept Civil Engn, Tehran, Iran
[2] Qazvin Azad Univ, Dept Civil Engn, Qazvin, Iran
关键词
Post-tensioned connection; Self-centering moment-resisting frame; Stiffeners; Energy dissipation; Ductility; BEHAVIOR; DESIGN;
D O I
10.1007/s13296-018-0138-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Beam-to-column connections with post-tensioned (PT) elements are used in steel moment-resisting frames to provide adequate stiffness, strength, and ductility and to eliminate residual displacements under seismic loads. A steel PT connection has recently been developed with top and seat angles. In this connection, angles are used to dissipate energy under cyclic loading. This paper aims to investigate the influence of adding stiffeners to the top and seat angles on the cyclic responses of PT connections. To this end, a parametric study is performed to compare the effectiveness of stiffeners and some design parameters in the cyclic behavior of the PT connections. The design parameters are the angle thickness, the distance between the bolt line passing through the column and the heel of the angle (g(2)), the PT force of the strands, and number of strands. First, the results of finite element analyses are compared to previously conducted experiments on PT connections with top and seat angles through a verification study. In this way, finite element models of 23 PT connections are developed and analyzed under cyclic loading. Results indicate that adding the stiffeners to the angles, enhances the energy dissipation capacity, moment capacity, stiffness and ductility of the PT connection much higher than improving other design parameters.
引用
收藏
页码:478 / 494
页数:17
相关论文
共 50 条
  • [21] Flexural strength analysis of non-post-tensioned and post-tensioned concrete-filled circular steel tubes
    Deng, Y.
    Tuan, C. Y.
    Zhou, Q.
    Xiao, Y.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (02) : 192 - 202
  • [22] Centralized semi-active control of post-tensioned steel frames
    Eljajeh, Yasser
    Petkovski, Mihail
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (01) : 79 - 100
  • [23] Development of repairability index for steel moment frames with post-tensioned self-centering connections
    Bavandi, Mohammad
    Moghadam, Abdolreza S.
    Mansoori, Mohammad Reza
    Aziminejad, Armin
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 318
  • [24] Experimental study on self-centering link beams using post-tensioned steel-SMA composite tendons
    Xu, Xian
    Tu, Jiaqi
    Cheng, Guangming
    Zheng, Junhua
    Luo, Yaozhi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 155 : 121 - 128
  • [25] Optimization for friction damped post-tensioned steel frame based on simplified FE model and GA
    Zhao Zhongwei
    Ian Xiangyang
    Yuan Ye
    Liu Haiqing
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2022, 21 (01) : 209 - 219
  • [26] Improved performance-based plastic design method for post-tensioned connection systems
    Moradifard, R.
    Alibazi, A.
    Shiravand, M. R.
    Gholami, M.
    ENGINEERING STRUCTURES, 2022, 255
  • [27] Seismic response of complex 3D steel buildings with welded and post-tensioned connections
    Reyes-Salazar, Alfredo
    Ruiz, Sonia E.
    Bojorquez, Eden
    Bojorquez, Juan
    Llanes-Tizoc, Mario D.
    EARTHQUAKES AND STRUCTURES, 2016, 11 (02) : 217 - 243
  • [28] A post-tensioned hybrid beam-column connection with a web friction device: Experimental study and theoretical analysis
    Feng, Shiqiang
    Yang, Yong
    Xue, Yicong
    Yu, Yunlong
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [29] Numerical investigations on mechanical behavior of friction damped post-tensioned steel connections
    Zhongwei Zhao
    Jinjia Wu
    Bing Liang
    Haiqing Liu
    Qingwei Sun
    Archive of Applied Mechanics, 2018, 88 : 2247 - 2260
  • [30] Collapse performance of post-tensioned steel frames considering influence of infill walls
    Shan, Sidi
    Li, Shuang
    STRUCTURES, 2023, 58