Strength and modulus degradation of carbon fiber-reinforced polymer laminates from fiber misalignment

被引:14
作者
Yang, XB
Nanni, A
Haug, S
Sun, CL
机构
[1] Modjeski & Masters Inc, St Louis, MO 63102 USA
[2] Univ Missouri, Ctr Infrastruct Engn Studies, Rolla, MO 65409 USA
关键词
fiber-reinforced materials; polymers; degradation; laminates; size effect; stiffness; strength;
D O I
10.1061/(ASCE)0899-1561(2002)14:4(320)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber-reinforced polymer (FRP) laminates are being used as external reinforcement for strengthening concrete members. The performance of unidirectional FRP laminates is highly dependent on fiber orientation with respect to applied load direction. In the case of fabrication by manual layup, it is possible to have fiber plies installed with improper orientation. In this project, the degradation of strength and modulus of carbon FRP laminates from fiber misalignment was investigated experimentally using tensile coupons. The specimens consisted of one and two plies of unidirectional carbon FRP impregnated with a two-component epoxy. The misalignment angles varied from 0 to 40degrees for the one-ply samples, and from 0 to 90degrees for one ply of the two-ply samples. The size effect on the strength and modulus was investigated for one-ply specimens with misalignments of 5 and 10degrees. For these specimens, the ply width was maintained constant and the length was varied so that the aspect ratio ranged between 2 and 8. It was concluded that misalignment affects strength more than elastic modulus. However, provided that mechanical parameters are related to the cross-sectional area of laminate with fibers continuous from end to end of the coupon, the degradation of strength can be accounted with a knock-down factor that is independent of misalignment angle.
引用
收藏
页码:320 / 326
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 1985, STATIC TEST METHODS
[2]  
ASTM (American Society for Testing and Materials), 1995, D3039D3039M ASTM
[3]  
DOLAN CW, 1999, P 4 INT S AM CONCR I
[4]   Tensile strength and its scatter of unidirectional carbon fibre reinforced composites [J].
Hamada, H ;
Oya, N ;
Yamashita, K ;
Maekawa, ZI .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1997, 16 (02) :119-130
[5]   INFLUENCE OF CLAMPING METHOD ON TENSILE PROPERTIES OF UNIDIRECTIONAL CFRP IN 0-DEGREES AND 90-DEGREES DIRECTIONS - ROUND-ROBIN ACTIVITY FOR INTERNATIONAL STANDARDIZATION IN JAPAN [J].
HOJO, M ;
SAWADA, Y ;
MIYAIRI, H .
COMPOSITES, 1994, 25 (08) :786-796
[6]  
NANNI A, 1993, P INT S AM CONCR I D
[7]  
NANNI A, 1998, P 2 INT C COMP INFR, V1, P187
[8]  
Saadatmanesh H., 1998, J. Compos. Construct., V3, P158, DOI [10.1061/(ASCE)1090-0268(1998)2:4(158), DOI 10.1061/(ASCE)1090-0268(1998)2:4(158)]
[9]  
*STRUCT PRES SYST, 1998, MBRAC COMP STRENGTH
[10]  
TAERWE L, 1995, P 2 INT RILEM S RILE