UV degradation of the optical properties of acrylic for neutrino and dark matter experiments

被引:8
作者
Littlejohn, B. [1 ]
Heeger, K. M. [1 ]
Wise, T. [1 ]
Gettrust, E. [2 ]
Lyman, M. [2 ]
机构
[1] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
[2] Madison W High Sch, Madison, WI 53726 USA
来源
JOURNAL OF INSTRUMENTATION | 2009年 / 4卷
关键词
Spectrometers; Radiation and optical windows; POLY(METHYL METHACRYLATE); DETECTOR;
D O I
10.1088/1748-0221/4/09/T09001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
UV-transmitting (UVT) acrylic is a commonly used light-propagating material in neutrino and dark matter detectors as it has low intrinsic radioactivity and exhibits low absorption in the detectors' light producing regions, from 350 nm to 500 nm. Degradation of optical transmittance in this region lowers light yields in the detector, which can affect energy reconstruction, resolution, and experimental sensitivities. We examine transmittance loss as a result of short-and long-term UV exposure for a variety of UVT acrylic samples from a number of acrylic manufacturers. Significant degradation peaking at 343 nm was observed in some UVT acrylics with as little as three hours of direct sunlight, while others exhibited softer degradation peaking at 310 nm over many days of exposure to sunlight. Based on their measured degradation results, safe time limits for indoor and outdoor UV exposure of UVT acrylic are formulated.
引用
收藏
页数:13
相关论文
共 17 条
[1]  
[Anonymous], COMMUNICATION
[2]  
[Anonymous], P IEEE PVSC
[3]  
Ardellier F., HEPEX0606025 DOUBLE
[4]  
*ASTM, G17303E1 ASTM
[6]  
BOULAY MG, ASTROPH0411358
[7]   Experimental results from an antineutrino detector for cooperative monitoring of nuclear reactors [J].
Bowden, N. S. ;
Bernstein, A. ;
Allen, M. ;
Brennan, J. S. ;
Cunningham, M. ;
Estrada, J. K. ;
Greaves, C. M. R. ;
Hagmann, C. ;
Lund, J. ;
Mengesha, W. ;
Weinbeck, T. D. ;
Winant, C. D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02) :985-998
[8]  
Chen MC, 2007, AIP CONF PROC, V944, P25, DOI 10.1063/1.2818544
[9]   PHOTOLYTIC DEGRADATION OF POLY(METHYL METHACRYLATE) [J].
FOX, RB ;
ISAACS, LG ;
STOKES, S .
JOURNAL OF POLYMER SCIENCE PART A-GENERAL PAPERS, 1963, 1 (03) :1079-&
[10]   The Super-Kamiokande detector [J].
Fukuda, S ;
Fukuda, Y ;
Hayakawa, T ;
Ichihara, E ;
Ishitsuka, M ;
Itow, Y ;
Kajita, T ;
Kameda, J ;
Kaneyuki, K ;
Kasuga, S ;
Kobayashi, K ;
Kobayashi, Y ;
Koshio, Y ;
Miura, M ;
Moriyama, S ;
Nakahata, M ;
Nakayama, S ;
Namba, T ;
Obayashi, Y ;
Okada, A ;
Oketa, M ;
Okumura, K ;
Oyabu, T ;
Sakurai, N ;
Shiozawa, M ;
Suzuki, Y ;
Takeuchi, Y ;
Toshito, T ;
Totsuka, Y ;
Yamada, S ;
Desai, S ;
Earl, M ;
Hong, JT ;
Kearns, E ;
Masuzawa, M ;
Messier, MD ;
Stone, JL ;
Sulak, LR ;
Walter, CW ;
Wang, W ;
Scholberg, K ;
Barszczak, T ;
Casper, D ;
Liu, DW ;
Gajewski, W ;
Halverson, PG ;
Hsu, J ;
Kropp, WR ;
Mine, S ;
Price, LR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (2-3) :418-462