Enantioselective analysis of ibuprofen in human plasma by anionic cyclodextrin-modified electrokinetic chromatography

被引:0
|
作者
Jabor, VAP
Lanchote, VL
Bonato, PS
机构
[1] USP, Fac Ciencias Farmaceut, Dept Fis & Quim, BR-14040903 Ribeirao Preto, SP, Brazil
[2] USP, Fac Filosofia Ciencias & Letras Ribeirao Pret, Dept Quim, BR-14040903 Ribeirao Preto, SP, Brazil
[3] USP, Fac Ciencias Farmaceut, Dept Analises Clin, BR-14040903 Ribeirao Preto, SP, Brazil
关键词
capillary electrophoresis; enantiomeric separation; ibuprofen; plasma samples; validation;
D O I
10.1002/1522-2683(200209)23:17<3041::AID-ELPS3041>3.0.CO;2-Q
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCI followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L-1 phosphoric acid/ triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 mug mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 mug mL-1) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 mug mL(-1) for (+)-(S)and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 mug mL(-1) of (-)-(R)- and (+)-(S)- ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-chi) (+)-(S)/AUC(0-chi) (-)-(R) ratio was 1.87.
引用
收藏
页码:3041 / 3047
页数:7
相关论文
共 50 条
  • [21] Analytical Quality by Design-Compliant Development of a Cyclodextrin-Modified Micellar ElectroKinetic Chromatography Method for the Determination of Trimecaine and Its Impurities
    Marzullo, Luca
    Gotti, Roberto
    Orlandini, Serena
    Slavickova, Patricie
    Jires, Jakub
    Zapadlo, Michal
    Dousa, Michal
    Nekvapilova, Pavla
    Rezanka, Pavel
    Furlanetto, Sandra
    MOLECULES, 2023, 28 (12):
  • [22] Chiral separation of pemoline enantiomers by cyclodextrin-modified micellar capillary chromatography
    Zhu, CF
    Lin, XL
    Wei, YJ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (02) : 293 - 298
  • [23] On the zopiclone enantioselective binding to human albumin and plasma proteins. An electrokinetic chromatography approach
    Asensi-Bernardi, L.
    Martin-Biosca, Y.
    Medina-Hernandez, M. J.
    Sagrado, S.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (20) : 3111 - 3117
  • [24] Enantioseparation of (±)-threo-methylphenidate in human plasma by cyclodextrin-modified sample stacking capillary electrophoresis
    Lee, Shih-Chieh
    Wang, Chun-Chi
    Yang, Pin-Chen
    Wu, Shou-Mei
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1232 : 302 - 305
  • [25] Direct enantioseparation of catechin and epicatechin in tea drinks by 6-O-α-D-glucosyl-β-cyclodextrin-modified micellar electrokinetic chromatography
    Kodama, S
    Yamamoto, A
    Matsunaga, A
    Yanai, H
    ELECTROPHORESIS, 2004, 25 (16) : 2892 - 2898
  • [26] Qualitative determination of proanthocyanidin cleavage products after acid-catalyzed degradation in the presence of excess phloroglucinol by cyclodextrin-modified micellar electrokinetic chromatography
    Qa'dan, Fadi
    Petereit, Frank
    Lechtenberg, Matthias
    Nahrstedt, Adolf
    PHARMACEUTICAL BIOLOGY, 2006, 44 (04) : 309 - 314
  • [27] Enantiomeric separation of selenoaminoacid derivatives by cyclodextrin-modified micellar electrokinetic chromatography using a mixed micellar system of sodium dodecyl sulphate and taurodeoxycholic acid
    Méndez, AP
    González, EB
    Sanz-Medel, A
    ANALYTICA CHIMICA ACTA, 2000, 416 (01) : 1 - 7
  • [28] Separation of phthalates by cyclodextrin modified micellar electrokinetic chromatography: Quantitation in perfumes
    Perez-Fernandez, Virginia
    Jose Gonzalez, Maria
    Angeles Garcia, Maria
    Luisa Marina, Maria
    ANALYTICA CHIMICA ACTA, 2013, 782 : 67 - 74
  • [29] Chemometrics-guided development of a cyclodextrin-modified micellar electrokinetic chromatography method with head-column field amplified sample stacking for the analysis of 5-lipoxygenase metabolites
    Abromeit, Hans
    Schaible, Anja M.
    Werz, Oliver
    Scriba, Gerhard K. E.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 217 - 223
  • [30] Construction of beta-cyclodextrin modified holographic sensor for the determination of ibuprofen in plasma and urine
    Yu, Jing
    Gai, Zhengxiao
    Cheng, Jiayi
    Tian, Feng
    Wei, Wei
    Li, Yang
    Gao, Qingyu
    Zou, Chenyang
    Qian, Rumeng
    Sun, Zhaomei
    Song, Xinyue
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 385