Numerical study on the operating characteristics of cryogenic loop heat pipes based on a one-dimensional heat leak model

被引:32
作者
Qu, Z. G. [1 ]
Chen, G. [1 ]
Zhou, L. [1 ]
Miao, J. Y. [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, MOE Key Lab Thermal Fluid Sci & Engn, Xian 710049, Shaanxi, Peoples R China
[2] Beijing Inst Spacecraft Syst Engn, Beijing Key Lab Space Thermal Control Technol, Beijing 100094, Peoples R China
基金
中国国家自然科学基金;
关键词
Cryogenic loop heat pipe; Heat leak; Operating characteristics; Bayonet; PARAMETRIC ANALYSIS; WORKING FLUID; CLHP;
D O I
10.1016/j.enconman.2018.07.036
中图分类号
O414.1 [热力学];
学科分类号
摘要
The cryogenic loop heat pipe is an effective and reliable heat transfer system in the space technology. A global model of cryogenic loop heat pipe is developed by full consideration of the subcooled effect and the mass flow rate variation of the working fluid along the evaporator core. The heat leak is calculated on the basis of onedimensional temperature distributions in the evaporator core. The calculation of the proposed model improves the prediction accuracy relative to traditional zero-dimensional models. The effects of filling pressure, parasitic heat load, auxiliary heat load, and use of bayonet on the CLHP performance are investigated. A normal "U shape" of the evaporating temperature curve appears at a low filling pressure (1.45 MPa). At moderate and high filling pressures (1.465 MPa and 1.5 MPa, respectively), two new evaporating temperature curves with "flat bottom U-shape" and "L-shape", which shows the unique operating characteristics of cryogenic loop heat pipes, are found, The two new profiles are attributed to the coupling of mass and energy between gas reservoir and primary compensation chamber. The determinant factor for the minimum working heat load is the void fraction of the primary compensation chamber. By contrast, the maximum working heat load is determined by the void fraction at a low filling pressure (below 1.4 MPa) and the maximum capillary pressure at a high filling pressure (above 1.4 MPa). The use of a bayonet can decrease the maximum vapor quality in the evaporator core and effectively avoid burnout.
引用
收藏
页码:485 / 496
页数:12
相关论文
共 21 条
  • [1] Thermohydraulic modeling of capillary pumped loop and loop heat pipe
    Adoni, Abhijit A.
    Ambirajan, Amrit
    Jasvanth, V. S.
    Kumar, D.
    Dutta, Pradip
    Srinivasan, K.
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2007, 21 (02) : 410 - 421
  • [2] Theoretical Studies of Hard Filling in Loop Heat Pipes
    Adoni, Abhijit A.
    Ambirajan, Amrit
    Jasvanth, V. S.
    Kumar, D.
    Dutta, Pradip
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2010, 24 (01) : 173 - 183
  • [3] Effects of Mass of Charge on Loop Heat Pipe Operational Characteristics
    Adoni, Abhijit A.
    Ambirajan, Amrit
    Jasvanth, V. S.
    Kumar, Dinesh
    Dutta, Pradip
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2009, 23 (02) : 346 - 355
  • [4] [Anonymous], 2016, NIST REF FLUID THERM, V9, P55
  • [5] Modeling and Analysis of Supercritical Startup of a Cryogenic Loop Heat Pipe
    Bai, Lizhan
    Lin, Guiping
    Peterson, G. P.
    Wen, Dongsheng
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (12):
  • [6] Parametric analysis of steady-state operation of a CLHP
    Bai, Lizhan
    Lin, Guiping
    Wen, Dongsheng
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) : 850 - 858
  • [7] Mathematical modeling of steady-state operation of a loop heat pipe
    Bai, Lizhan
    Lin, Guiping
    Zhang, Hongxing
    Wen, Dongsheng
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (13) : 2643 - 2654
  • [8] Chuang P.-Y.A., 2003, An Improved Steady-State Model of Loop Heat Pipe Based on Experimental and Theorical Analyses
  • [9] Determination of charged pressure of working fluid and its effect on the operation of a miniature CLHP
    Du, Chenhui
    Bai, Lizhan
    Lin, Guiping
    Zhang, Hongxing
    Miao, Jianyin
    Wen, Dongsheng
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 63 : 454 - 462
  • [10] Thermal behavior of a cryogenic loop heat pipe for space application
    Gully, Philippe
    Mo, Qing
    Yan, Tao
    Seyfert, Peter
    Guillemet, Laurent
    Thibault, Pierre
    Liang, Jingtao
    [J]. CRYOGENICS, 2011, 51 (08) : 420 - 428